Vergleichsstudie in der Zeitschrift British Journal of Radiology, 2026. Verfasst von Rodi Ertogrul und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, Medical Faculty, Istanbul Medipol University, Istanbul 34810, Turkey. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Arthrography, Rotator Cuff, Shoulder Joint. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To evaluate the diagnostic value of sonoarthrography (SA) for the superior glenohumeral ligament (SGHL) and long head of the biceps tendon (LHBT) in the rotator interval (RI), and to compare its performance with ultrasonography (US) and magnetic resonance imaging (MRI), using magnetic resonance arthrography (MRA) as the reference standard.

Methods

A total of 63 patients with suspected pathologies of the RI were evaluated prospectively. Each patient underwent conventional shoulder US and MRI without intra-articular contrast solution injection and SA and MRA following the injection of an intra-articular contrast solution. Two independent observers evaluated the detectability and pathological characteristics of the SGHL and the LHBT. Diagnostic performance was quantified based on sensitivity, specificity, and accuracy, while interobserver agreement was determined through kappa statistics.

Results

According to the first and second observers, the sensitivity and specificity values of US, SA, and MRI in the evaluation of LHBT pathologies were 77.3% and 86.4%-100% and 100%; 90.9% and 95.5%-100% and 100%; and 100% and 100%-100% and 100%, respectively. For SGHL pathologies, the corresponding values were 41.9% and 64.5%-96.9% and 100%; 71% and 74.2%-100% and 100%; and 58.1% and 58.1%-93.8% and 100%, respectively. The interobserver reliability was almost perfect for SGHL (κ = 0.896; 95% CI, 0.782-1.000) and almost perfect for LHBT (κ = 0.964; 95% CI, 0.894-1.000). For SGHL, SA significantly outperformed US in the less experienced observer (exact McNemar P = .0039; AUC 0.823 vs 0.632, DeLong P = .0002) and exceeded MRI on AUC comparison in the more experienced observer (0.839 vs 0.758, P = .048); interobserver agreement with SA (κ = 0.896) was markedly higher than with US (κ = 0.602). For LHBT, SA was numerically superior to US and comparable to MRI.

Conclusion

Sonoarthrography is useful for assessing the RI, improving sonographic assessment of the SGHL and substantially reducing interobserver variability compared with conventional US, while maintaining comparable accuracy for the LHBT. This technique can serve as an alternative when MRI is contraindicated or unavailable. Advances in knowledge The rotator interval is a complex triangular region located in the anterosuperior aspect of the glenohumeral joint. The cohesive stabilizing role of its anatomical components is critical for maintaining passive stability. Ultrasonography may not consistently provide reliable visualization of the deep ligamentous structures within the rotator interval. Sonoarthrography has a high diagnostic accuracy in the assessment of rotator interval structures. Clinical trial number Protocol code: 2022/51, date of approval: April 25, 2022.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingArthrographyRotator CuffShoulder JointLigaments, ArticularHumansUltrasonographyFemaleSensitivity and SpecificityProspective StudiesMaleMiddle AgedAdultAgedReference StandardsContrast MediaReproducibility of Results

Stichwörter der Autor:innen

MR arthrographybiceps tendonrotator intervalshouldersonoarthrographysuperior glenohumeral ligament

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Department of Orthopedic Surgery, Medical Faculty, Istanbul Medipol University, Istanbul 34810, Turkey.
  • Department of Radiology, Medical Faculty, Istanbul Medipol University, Istanbul 34810, Turkey.
  • Department of Radiology, Health Sciences University, Umraniye Training and Research Hospital, Istanbul 34764, Turkey.
  • Department of Radiology, Duzce University, Duzce 81620, Turkey.
  • Department of Orthopedic Surgery, Sisli Hamidiye Etfal Training and Research Hospital, Health Sciences University, Istanbul 34453, Turkey.

ORCID-Profile: Hayri Ogul, Zakir Sakci, Ayse Gokce

Zitieren

APA

Ertogrul, R., Ogul, H., Yahsi, Y., Sakci, Z., Guclu, D., Gokce, A., Altuntas, Y., & Unlu, E. N. (2026). Diagnostic value of sonoarthrography in rotator interval imaging: a comparative study using MR arthrography as the reference standard. British Journal of Radiology. https://doi.org/10.1093/bjr/tqag231

Vancouver

Ertogrul R, Ogul H, Yahsi Y, Sakci Z, Guclu D, Gokce A, et al. Diagnostic value of sonoarthrography in rotator interval imaging: a comparative study using MR arthrography as the reference standard. British Journal of Radiology. 2026. doi:10.1093/bjr/tqag231

BibTeX
@article{Ertogrul2026,
  author = {Ertogrul, Rodi and Ogul, Hayri and Yahsi, Yusuf and Sakci, Zakir and Guclu, Derya and Gokce, Ayse and Altuntas, Yusuf and Unlu, Elif Nisa},
  title = {Diagnostic value of sonoarthrography in rotator interval imaging: a comparative study using MR arthrography as the reference standard},
  journal = {British Journal of Radiology},
  year = {2026},
  doi = {10.1093/bjr/tqag231}
}
Kostenlos starten →