From shadows to signals: exploring the strengths and limitations of artificial intelligence in breast cancer lesion detection on screening mammograms compared to radiologists and radiology trainees
British Journal of Radiology · 2026
DOI: 10.1093/bjr/tqag177 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift British Journal of Radiology, 2026. Verfasst von Phuong Dung Yun Trieu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Discipline of Medical Imaging Sciences, Sydney School of Health Sciences, Faculty of Medicine and Health, The University of Sydney, Camperdown, NSW 2…. Hauptthemen laut MEDLINE: Breast Neoplasms, Mammography, Artificial Intelligence, Radiologists. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NBCF.
Abstract (Originalsprache)
Objectives
Breast cancer screening with mammography reduces mortality, but interpretation errors persist. While artificial intelligence (AI) shows promise, most studies focus on case-level accuracy and overlook lesion-level performance. This study evaluated the AI (GMIC + CLAHE) model against radiologists and radiology trainees, considering breast density and lesion characteristics.
Methods
Nine BREAST test sets of screening digital mammograms (540 cases: 179 cancer, 361 normal) were analyzed. AI performance was compared with 17 radiologists and 26 trainees. Case- and lesion-level performance were assessed across breast density, lesion type, and size. AI malignancy scores were dichotomized using Youden’s index. Sensitivity, specificity, ROC AUC, lesion localization, and odds ratios (ORs) were calculated.
Results
AI achieved higher case-level AUC (0.974) than radiologists (0.82 ± 0.06; P = .01) and trainees (0.74 ± 0.05; P < .0001) across breast densities. At lesion level, AI matched radiologists and outperformed trainees (OR = 1.6; P = .03), with lesion sensitivities of 66.3% (AI), 67.0% (radiologists), and 55.0% (trainees). AI also outperformed trainees in detecting mixed-type lesions (75% vs 55%; OR = 2.4) and small lesions ≤15 mm (65.7% vs 55%; OR = 1.6). Architectural distortion had the highest miss rate (43.8%) whereas mixed-type lesions demonstrated the lowest miss rate (25.0%) by AI.
Conclusions
AI demonstrated superior case-level accuracy compared with radiologists and trainees, but limitations in localizing specific lesion types, supporting its role as an adjunct to human readers in screening and training. Advances in knowledge This study integrates case-and-lesion-level evaluation in different case characteristics, identifying key strengths and limitations for clinical implementation. Despite superior case-level accuracy, variability in lesion localization across cancer types and sizes highlights important considerations for its integration into screening services.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Discipline of Medical Imaging Sciences, Sydney School of Health Sciences, Faculty of Medicine and Health, The University of Sydney, Camperdown, NSW 2006, Australia.
- Faculty of Health, Western Sydney University, Campbelltown 2560, Australia.
ORCID-Profile: Phuong Dung Yun Trieu, Zhengqiang Jiang, Seyedamir Tavakoli Taba, Minyan Zeng, Dania Abu Awwad, Melissa L Barron, Sarah J Lewis
Förderung
- NBCF
Zitieren
APA
Trieu, P. D. Y., Jiang, Z., Tavakoli Taba, S., Zeng, M., Awwad, D. A., Barron, M. L., & Lewis, S. J. (2026). From shadows to signals: exploring the strengths and limitations of artificial intelligence in breast cancer lesion detection on screening mammograms compared to radiologists and radiology trainees. British Journal of Radiology. https://doi.org/10.1093/bjr/tqag177
Vancouver
Trieu PDY, Jiang Z, Tavakoli Taba S, Zeng M, Awwad DA, Barron ML, et al. From shadows to signals: exploring the strengths and limitations of artificial intelligence in breast cancer lesion detection on screening mammograms compared to radiologists and radiology trainees. British Journal of Radiology. 2026. doi:10.1093/bjr/tqag177
BibTeX
@article{Trieu2026,
author = {Trieu, Phuong Dung Yun and Jiang, Zhengqiang and Tavakoli Taba, Seyedamir and Zeng, Minyan and Awwad, Dania Abu and Barron, Melissa L and Lewis, Sarah J},
title = {From shadows to signals: exploring the strengths and limitations of artificial intelligence in breast cancer lesion detection on screening mammograms compared to radiologists and radiology trainees},
journal = {British Journal of Radiology},
year = {2026},
doi = {10.1093/bjr/tqag177}
}
EUVIMED