EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Reproducibility of automated opportunistic CT-based volumetric bone mineral density measurements at the thoracic spine

Philipp Raffler iD, Jannis Bodden, Katharina Schultes, Philipp Prucker, Daniela Pfeiffer iD, Arthur Wagner, Malek El Husseini, Jan S Kirschke, Sebastian Rühling

British Journal of Radiology · 2026

DOI: 10.1093/bjr/tqag175 ↗

Kurz gefasst

Fachartikel in der Zeitschrift British Journal of Radiology, 2026. Verfasst von Philipp Raffler und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neuroradiology, TUM School of Medicine and Health, TUM Klinikum Rechts der Isar, Technical University of Munich, Munich, BY 81675, Germ…. Hauptthemen laut MEDLINE: Thoracic Vertebrae, Bone Density, Tomography, X-Ray Computed, Osteoporosis. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Bavarian Research Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Opportunistic CT-based screening for osteoporosis has been shown to be cost-effective and may help to reduce the existing treatment gap in patients. Reproducibility has not yet been investigated at thoracic levels, which is becoming increasingly relevant with upcoming lung cancer screening programs.

Methods

Scans from 178 patients with 2 consecutive CT examinations within 1 month were retrospectively included. In all available reconstructions, automated extraction of trabecular volumetric bone mineral density (vBMD) was performed, including HU-to-BMD conversion and contrast phase correction. Mean trabecular vBMD was calculated for 2 thoracic regions (T5-T7 and T8-T10). Reproducibility was calculated as the root mean square coefficient of variation (RMSCV) under 6 reproducibility scenarios, ranging from different reconstructions of the same scan to measurements across different scanners and contrast phases.

Results

In total, 914 vBMD observations were analyzed. RMSCV values ranged from 0.83% to 4.90% for T5-T7 and from 1.4% to 6.8% for T8-T10. One-way ANOVA showed a significant overall difference between reproducibility scenarios in both vertebral regions (all P < .001), with post hoc analyses demonstrating a stepwise increase in RMSCV with technical complexity.

Conclusions

Our results support the clinical applicability of opportunistic osteoporosis screening at the thoracic spine across diverse CT acquisition protocols. With the upcoming national lung cancer screening programs utilizing low-dose CT (LDCT), an extraordinary opportunity emerges to address the substantial osteoporosis treatment gap through opportunistic bone health assessment. Advances in knowledge This work is novel in extending reproducibility validation for opportunistic osteoporosis screening from the lumbar spine to thoracic vertebrae.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Thoracic VertebraeBone DensityTomography, X-Ray ComputedOsteoporosisHumansReproducibility of ResultsFemaleRetrospective StudiesMaleAgedMiddle AgedAged, 80 and over

Stichwörter der Autor:innen

automated vBMDbone health assessmentopportunistic screeningosteoporosisreproducibility

Autor:innen und Institutionen

  • Department of Neuroradiology, TUM School of Medicine and Health, TUM Klinikum Rechts der Isar, Technical University of Munich, Munich, BY 81675, Germany.
  • Department of Radiology, TUM School of Medicine and Health, TUM Klinikum Rechts der Isar, Technical University of Munich, Munich, BY 81675, Germany.
  • Department of Neurosurgery, TUM School of Medicine and Health, TUM Klinikum Rechts der Isar, Technical University of Munich, Munich, BY 81675, Germany.
  • TUM-Neuroimaging Center, TUM Klinikum Rechts der Isar, Technical University of Munich, Munich, BY 81675, Germany.

ORCID-Profile: Philipp Raffler, Daniela Pfeiffer

Förderung

  • Bavarian Research Foundation

Zitieren

APA

Raffler, P., Bodden, J., Schultes, K., Prucker, P., Pfeiffer, D., Wagner, A., El Husseini, M., Kirschke, J. S., & Rühling, S. (2026). Reproducibility of automated opportunistic CT-based volumetric bone mineral density measurements at the thoracic spine. British Journal of Radiology. https://doi.org/10.1093/bjr/tqag175

Vancouver

Raffler P, Bodden J, Schultes K, Prucker P, Pfeiffer D, Wagner A, et al. Reproducibility of automated opportunistic CT-based volumetric bone mineral density measurements at the thoracic spine. British Journal of Radiology. 2026. doi:10.1093/bjr/tqag175

BibTeX
@article{Raffler2026,
  author = {Raffler, Philipp and Bodden, Jannis and Schultes, Katharina and Prucker, Philipp and Pfeiffer, Daniela and Wagner, Arthur and El Husseini, Malek and Kirschke, Jan S and Rühling, Sebastian},
  title = {Reproducibility of automated opportunistic CT-based volumetric bone mineral density measurements at the thoracic spine},
  journal = {British Journal of Radiology},
  year = {2026},
  doi = {10.1093/bjr/tqag175}
}
Kostenlos starten →