Impact of a structured quantitative program on [18F]FP-CIT PET interpretation: a multicenter study of diagnostic accuracy, interrater reliability, and reader confidence
British Journal of Radiology · 2026
DOI: 10.1093/bjr/tqag045 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift British Journal of Radiology, 2026. Verfasst von Byungwook Choi und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nuclear Medicine, Daegu Catholic University Hospital and School of Medicine, Daegu, 42472, Republic of Korea. Hauptthemen laut MEDLINE: Positron-Emission Tomography, Parkinson Disease, Tropanes, Essential Tremor. Gefördert von: Korea Health Industry Development Institute and Daegu Metropolitan city.
Abstract (Originalsprache)
Objectives
This study assessed the impact of a structured quantitative analysis program on diagnostic performance, interrater reliability, and reader confidence in interpreting N-3-[18F]fluoropropyl-2β-carbomethoxy-3β-4-iodophenyl nortropane positron emission tomography ([18F]FP-CIT PET) scans to differentiate idiopathic Parkinson’s disease from essential tremor-/drug-induced parkinsonism.
Methods
This retrospective multicentre study included 637 patients who underwent [18F]FP-CIT PET and brain magnetic resonance imaging scans for evaluation of Parkinsonian syndromes at 4 institutions between January 2015 and October 2022. Readers evaluated the scans qualitatively in the pre-program session and with access to quantitative parameters in the post-program session, with a 1-month minimum interval to minimize recall bias. Diagnostic performance metrics (sensitivity, specificity, accuracy), interrater reliability (Cohen’s κ), and reader confidence (low/moderate vs. high) were compared.
Results
Following program implementation, interrater reliability significantly improved from substantial to almost perfect (Cohen’s κ: 0.768 to 0.970; p < 0.001), and a significant shift toward high-confidence ratings was observed (p < 0.001). Diagnostic accuracy also significantly improved from 92.8% to 94.3% (p = 0.036). Although the increase in the area under the curve (0.922 to 0.932) did not reach statistical significance (p = 0.163), likely due to a ceiling effect, reader performance significantly surpassed that of the quantitative parameter alone only after program implementation, whereas it was comparable at baseline.
Conclusions
These findings suggest that integrating quantitative analysis tools may improve diagnostic consistency and reliability in clinical practice. Advances in knowledge The structured quantitative analysis program significantly improved [18F]FP-CIT PET/CT interpretation by increasing diagnostic accuracy, interrater reliability, and reader confidence.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Nuclear Medicine, Daegu Catholic University Hospital and School of Medicine, Daegu, 42472, Republic of Korea.
- Division of Nuclear Medicine, Department of Radiology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, 06592, Republic of Korea.
- Division of Nuclear Medicine, Department of Radiology, Eunpyeong St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, 03312, Republic of Korea.
- Department of Nuclear Medicine, Kyungpook National University Hospital, Daegu, 41944, Republic of Korea.
- Department of Nuclear Medicine, Kyungpook National University School of Medicine, Daegu, 41944, Republic of Korea.
- Research Institute, Neurophet Inc, Seoul, 06234, Republic of Korea.
ORCID-Profile: Chae Moon Hong
Förderung
- Korea Health Industry Development Institute and Daegu Metropolitan city
Zitieren
APA
Choi, B., Ha, S., Kang, S., Kwon, S. J., Son, J., Jeong, S. Y., Lee, S. W., Choe, Y. S., Kim, D., & Hong, C. M. (2026). Impact of a structured quantitative program on [18F]FP-CIT PET interpretation: a multicenter study of diagnostic accuracy, interrater reliability, and reader confidence. British Journal of Radiology. https://doi.org/10.1093/bjr/tqag045
Vancouver
Choi B, Ha S, Kang S, Kwon SJ, Son J, Jeong SY, et al. Impact of a structured quantitative program on [18F]FP-CIT PET interpretation: a multicenter study of diagnostic accuracy, interrater reliability, and reader confidence. British Journal of Radiology. 2026. doi:10.1093/bjr/tqag045
BibTeX
@article{Choi2026,
author = {Choi, Byungwook and Ha, Seunggyun and Kang, Sungmin and Kwon, Soo Jin and Son, Junik and Jeong, Shin Young and Lee, Sang-Woo and Choe, Yeong Sim and Kim, Donghyeon and Hong, Chae Moon},
title = {Impact of a structured quantitative program on [18F]FP-CIT PET interpretation: a multicenter study of diagnostic accuracy, interrater reliability, and reader confidence},
journal = {British Journal of Radiology},
year = {2026},
doi = {10.1093/bjr/tqag045}
}