EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Low-dose corticomedullary phase CT urography with artificial intelligence iterative reconstruction for bladder cancer evaluation

Haifeng Liu iD, Xinrui Jiang iD, Tiantian Wang iD, Guozhi Zhang iD, Ming Zhao iD, Wei Xiang, Hongfen Peng iD

British Journal of Radiology · 2026

DOI: 10.1093/bjr/tqaf315 ↗

Kurz gefasst

Fachartikel in der Zeitschrift British Journal of Radiology, 2026. Verfasst von Haifeng Liu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Wuhan No.1 Hospital, Wuhan, Hubei 430022, China. Hauptthemen laut MEDLINE: Urinary Bladder Neoplasms, Tomography, X-Ray Computed, Urography, Artificial Intelligence. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To test the feasibility and quantify the performance of low-dose CT urography (CTU) with artificial intelligence iterative reconstruction (AIIR) for bladder cancer (BC) evaluation.

Methods

A total of 122 patients undergoing CTU examination were prospectively enrolled, where the routine-dose scan (120 kVp, ref 100 mAs) at corticomedullary phase (CMP) was followed immediately by a low-dose scan (120 kVp, ref 20 mAs). Routine-dose images were reconstructed with hybrid iterative reconstruction (HIR, RD-HIR), while low-dose images were with AIIR (LD-AIIR) and HIR (LD-HIR). The image quality was first evaluated regarding streak artefacts around the bladder and then in contrast-to-noise ratio (CNR) for various manifestations of bladder wall. The diagnostic performance of BC was characterized using receiver operating characteristic (ROC) analysis, in respect to the clinical diagnostic report.

Results

The effective dose at low-dose CMP was 80.2% lower than routine-dose scan (7.6 ± 1.2 vs 1.5 ± 0.3 mSv). Nineteen cases in LD-HIR were deemed clinically unacceptable for presenting severe artefacts around the bladder, while found well above the basic requirement in LD-AIIR. The highest CNR was found in LD-AIIR in all scenarios (all P < .001). The area under ROC curve in LD-AIIR was comparable to RD-HIR (0.988 vs 0.990, P = .172) and significantly higher than LD-HIR (0.988 vs 0.831, P < .001).

Conclusions

The low-dose AIIR protocol allows for a profound dose reduction (80.2%) while maintaining reliable diagnosis of BC on corticomedullary phase CTU images. Advances in knowledge Corticomedullary phase CTU with AIIR permits 80.2% dose reduction while preserving reliable BC diagnosis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Urinary Bladder NeoplasmsTomography, X-Ray ComputedUrographyArtificial IntelligenceRadiographic Image Interpretation, Computer-AssistedHumansMaleFemaleAgedMiddle AgedRadiation DosageProspective StudiesFeasibility StudiesAged, 80 and overAdultUrinary Bladder

Stichwörter der Autor:innen

CT urographyartificial intelligence iterative reconstructionbladder cancerradiation dosage

Autor:innen und Institutionen

  • Department of Radiology, Wuhan No.1 Hospital, Wuhan, Hubei 430022, China.
  • School of Laboratory Medicine, Hubei University of Chinese Medicine, Wuhan, Hubei 430065, China.
  • United Imaging Healthcare, Shanghai 201800, China.
  • Department of Urology, Wuhan No.1 Hospital, Wuhan, Hubei 430022, China.

ORCID-Profile: Haifeng Liu, Xinrui Jiang, Tiantian Wang, Guozhi Zhang, Ming Zhao, Hongfen Peng

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Liu, H., Jiang, X., Wang, T., Zhang, G., Zhao, M., Xiang, W., & Peng, H. (2026). Low-dose corticomedullary phase CT urography with artificial intelligence iterative reconstruction for bladder cancer evaluation. British Journal of Radiology. https://doi.org/10.1093/bjr/tqaf315

Vancouver

Liu H, Jiang X, Wang T, Zhang G, Zhao M, Xiang W, et al. Low-dose corticomedullary phase CT urography with artificial intelligence iterative reconstruction for bladder cancer evaluation. British Journal of Radiology. 2026. doi:10.1093/bjr/tqaf315

BibTeX
@article{Liu2026,
  author = {Liu, Haifeng and Jiang, Xinrui and Wang, Tiantian and Zhang, Guozhi and Zhao, Ming and Xiang, Wei and Peng, Hongfen},
  title = {Low-dose corticomedullary phase CT urography with artificial intelligence iterative reconstruction for bladder cancer evaluation},
  journal = {British Journal of Radiology},
  year = {2026},
  doi = {10.1093/bjr/tqaf315}
}
Kostenlos starten →