EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Impact of vessel size, dose levels, and body habitus on iodine quantification in cardiovascular photon-counting computed tomography

Martin V Rybertt iD, Leening P Liu iD, Manoj Mathew, Pooyan Sahbaee, Harold I Litt, Peter B Noël iD

British Journal of Radiology · 2025

DOI: 10.1093/bjr/tqaf181 ↗

Kurz gefasst

Fachartikel in der Zeitschrift British Journal of Radiology, 2025. Verfasst von Martin V Rybertt und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, United States. Hauptthemen laut MEDLINE: Iodine, Vascular Calcification, Tomography, X-Ray Computed. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIBIB NIH HHS, NIH HHS, Siemens Healthineers.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

This study evaluates the performance of a clinical dual-source photon-counting computed tomography (PCCT) system in quantifying iodine within calcified vessels, using 3D-printed phantoms with vascular-like structures lined with calcium.

Methods

Parameters assessed include lumen diameters (4, 6, 8, 10, and 12 mm), phantom sizes (S: 20 × 20 cm, M: 25 × 25 cm, L: 30 × 40 cm), and iodine concentrations (2, 5, and 10 mg/mL). Scans were performed with a cardiac high-pitch acquisition protocol at radiation dose levels of 5 and 10 mGy to systematically evaluate iodine quantification accuracy and spectral imaging performance.

Results

The results indicate that for lumen diameters ≥6 mm, iodine quantification remains stable across all dose levels and smaller phantom sizes, where error remained consistently below 0.9 mg/mL. Furthermore, iodine quantification revealed a significant dependence on phantom size while selected radiation dose levels were insignificant. Virtual monoenergetic imaging at 70 keV showed stable performance for larger lumens (≥6 mm) with variations of 20.3 ± 13.2 HU across all conditions, while smaller lumens remained stable in medium to small phantoms.

Conclusions

These findings highlight the influence of lumen diameter, patient size, and radiation dose in optimizing PCCT protocols for spectral imaging. Results indicate that PCCT maintains stable and precise imaging performance across diverse patient anatomies, with robust differentiation of iodine and calcium in adjacent regions. Advances in knowledge This study demonstrates PCCT's potential to enhance spectral imaging in vascular applications, characterizing iodine quantification at relevant lesion sizes for vascular imaging.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

IodineVascular CalcificationTomography, X-Ray ComputedPhantoms, ImagingHumansRadiation DosagePhotons

Stichwörter der Autor:innen

calcified plaquecoronary CTiodine quantificationlumen sizepatient habitusphoton-counting CT

Substanzen

Iodine

Autor:innen und Institutionen

  • Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, United States.
  • Department of Bioengineering, University of Pennsylvania, Philadelphia, PA 19104, United States.
  • Siemens Healthineers, Malvern, PA 19355, United States.

ORCID-Profile: Martin V Rybertt, Leening P Liu, Peter B Noël

Förderung

  • NIBIB NIH HHS
  • NIH HHS
  • Siemens Healthineers
  • National Institutes of Health

Zitieren

APA

Rybertt, M. V., Liu, L. P., Mathew, M., Sahbaee, P., Litt, H. I., & Noël, P. B. (2025). Impact of vessel size, dose levels, and body habitus on iodine quantification in cardiovascular photon-counting computed tomography. British Journal of Radiology. https://doi.org/10.1093/bjr/tqaf181

Vancouver

Rybertt MV, Liu LP, Mathew M, Sahbaee P, Litt HI, Noël PB. Impact of vessel size, dose levels, and body habitus on iodine quantification in cardiovascular photon-counting computed tomography. British Journal of Radiology. 2025. doi:10.1093/bjr/tqaf181

BibTeX
@article{Rybertt2025,
  author = {Rybertt, Martin V and Liu, Leening P and Mathew, Manoj and Sahbaee, Pooyan and Litt, Harold I and Noël, Peter B},
  title = {Impact of vessel size, dose levels, and body habitus on iodine quantification in cardiovascular photon-counting computed tomography},
  journal = {British Journal of Radiology},
  year = {2025},
  doi = {10.1093/bjr/tqaf181}
}
Kostenlos starten →