Differences between the image-derived input functions of the descending aorta and carotid artery in brain pharmacokinetic parametric analysis
British Journal of Radiology · 2025
DOI: 10.1093/bjr/tqaf166 ↗Kurz gefasst
Fachartikel in der Zeitschrift British Journal of Radiology, 2025. Verfasst von Zixiang Chen und 10 weiteren Autor:innen. Beteiligte Einrichtung: Research Center for Medical Artificial Intelligence, Shenzhen Institute of Advanced Technology, Chinese Academy of Science, Shenzhen 518055, China. Hauptthemen laut MEDLINE: Aorta, Thoracic, Carotid Arteries, Radiopharmaceuticals, Fluorodeoxyglucose F18. Die Arbeit nennt 25 Literaturangaben. Gefördert von: Shenzhen Medical Research Funds of China, National Natural Science Foundation of China, Natural Science Foundation of Guangdong Province in China.
Abstract (Originalsprache)
Objectives
This study aimed to quantitatively reveal the difference between the descending aorta image-derived input function (IDIFa) and carotid artery image-derived input function (IDIFc) in the task of brain pharmacokinetic parametric analysis.
Methods
18F-fluorodeoxyglucose (18F-FDG) dynamic positron emission tomography (PET) data from 50 patients collected by UIH uEXPLORER PET/CT were used to extract the IDIFa and IDIFc; the Patlak graphical model (PGM) and irreversible 2-tissue compartmental model (2TCM) were applied for brain pharmacokinetic parametric analysis. The Patlak Ki and Vt images yielded by the 2 types of IDIFs are compared using relative error (RE), while the parameters K1∼k3 and fv were analysed via paired t-tests to determine the significance of the differences.
Results
IDIFa and IDIFc had significant differences in peak value (P = 0.0009) and curve integral value (P = 0.0012). Based on PGM, 0%-15% REs were found between the Ki and Vt images yielded by IDIFa and IDIFc; based on 2TCM, significant differences were found in brainstem’s K1 (P = 0.0009), left cerebellum’s k3 (P = 0.0009) and all selected regions’ fv and Ki (P < 0.05). Fitting residuals of IDIFa are lower than that of IDIFc without significant differences (P > 0.05).
Conclusions
IDIFa and IDIFc have different curves characteristics and different brain pharmacokinetic parametric analysis results based on PGM and 2TCM. One should be prudential when using IDIFa to conduct brain dynamic PET parametric analysis. Advances in knowledge This study quantitatively compares carotid artery and descending aorta IDIFs in the term of brain pharmacokinetic analysis, providing an important reference for nuclear clinicians.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Research Center for Medical Artificial Intelligence, Shenzhen Institute of Advanced Technology, Chinese Academy of Science, Shenzhen 518055, China.
- University of Chinese Academy of Sciences, Beijing 101408, China.
- Department of Medical Imaging, Henan Provincial People's Hospital & People's Hospital of Zhengzhou University, Zhengzhou 450003, China.
- Institute for Integrated Medical Science and Engineering, Henan Academy of Sciences, Zhengzhou 450003, China.
- Central Research Institute, United Imaging Healthcare Group, Shanghai 201815, China.
- Key Laboratory of Biomedical Imaging Science and System, Chinese Academy of Sciences, Shenzhen 518055, China.
ORCID-Profile: Hairong Zheng, Zhanli Hu
Förderung
- Shenzhen Medical Research Funds of China
- National Natural Science Foundation of China
- Natural Science Foundation of Guangdong Province in China
- Basic and Applied Basic Research Foundation of Guangdong Province
- Shenzhen Excellent Technological Innovation Talent Training Project of China
Zitieren
APA
Chen, Z., Wu, Y., Li, B., Che, Z., Jin, Y., Chen, L., Yang, Y., Zheng, H., Liang, D., Wang, M., & Hu, Z. (2025). Differences between the image-derived input functions of the descending aorta and carotid artery in brain pharmacokinetic parametric analysis. British Journal of Radiology. https://doi.org/10.1093/bjr/tqaf166
Vancouver
Chen Z, Wu Y, Li B, Che Z, Jin Y, Chen L, et al. Differences between the image-derived input functions of the descending aorta and carotid artery in brain pharmacokinetic parametric analysis. British Journal of Radiology. 2025. doi:10.1093/bjr/tqaf166
BibTeX
@article{Chen2025,
author = {Chen, Zixiang and Wu, Yaping and Li, Bolun and Che, Zengyang and Jin, Yuxi and Chen, Lingxin and Yang, Yongfeng and Zheng, Hairong and Liang, Dong and Wang, Meiyun and Hu, Zhanli},
title = {Differences between the image-derived input functions of the descending aorta and carotid artery in brain pharmacokinetic parametric analysis},
journal = {British Journal of Radiology},
year = {2025},
doi = {10.1093/bjr/tqaf166}
}
EUVIMED