Quantitative CT imaging: where are we, and what is missing?
British Journal of Radiology · 01.11.2025 · 98 (1175) · 1834-1842
DOI: 10.1093/bjr/tqaf075 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift British Journal of Radiology, online erschienen am 07.04.2025. Verfasst von Kevin J Treb und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Mayo Clinic, Rochester, MN 55905, United States. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 98 Literaturangaben.
Abstract (Originalsprache)
Quantitative computed tomography (CT) enables the measurement of biophysical processes characterized by morphology, composition, flow, and/or motion to aid in clinical diagnosis and intervention. Since its initial application for determining bone mineral density for skeletal fragility assessment, quantitative CT has continued to evolve alongside CT’s technological advancements. A key challenge facing quantitative CT is the lack of standardization pertinent to image acquisition, reconstruction, and image analysis. With the introduction of spectral CT involving dual-energy approaches and photon-counting detectors (PCD), we are now able to obtain detailed information regarding mass densities of endogenous and exogeneous materials. Furthermore, energy-resolved CT yields spectral image types (eg, virtual monoenergetic image) that are, in principle, independent of tube potential and patient size. This paves the way for workflow standardization and helps improve the consistency and reproducibility of CT-derived measurements. In this article, we review clinical applications of quantitative CT, discuss key challenges associated with quantitative CT and its adoption into routine practice, and outline the unique benefits ushered by new CT technologies such as PCD-CT towards improving quantitative imaging.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Mayo Clinic, Rochester, MN 55905, United States.
ORCID-Profile: Shuai Leng, Lifeng Yu, Cynthia H McCollough, Kishore Rajendran
Zitieren
APA
Treb, K. J., El Sadaney, A. O., Ferrero, A., Baffour, F. I., Leng, S., Yu, L., Rajiah, P. S., Fletcher, J. G., McCollough, C. H., & Rajendran, K. (2025). Quantitative CT imaging: where are we, and what is missing?. British Journal of Radiology, 98(1175), 1834-1842. https://doi.org/10.1093/bjr/tqaf075
Vancouver
Treb KJ, El Sadaney AO, Ferrero A, Baffour FI, Leng S, Yu L, et al. Quantitative CT imaging: where are we, and what is missing?. British Journal of Radiology. 2025;98(1175):1834-1842. doi:10.1093/bjr/tqaf075
BibTeX
@article{Treb2025,
author = {Treb, Kevin J and El Sadaney, Ahmed O and Ferrero, Andrea and Baffour, Francis I and Leng, Shuai and Yu, Lifeng and Rajiah, Prabhakar Shantha and Fletcher, Joel G and McCollough, Cynthia H and Rajendran, Kishore},
title = {Quantitative CT imaging: where are we, and what is missing?},
journal = {British Journal of Radiology},
year = {2025},
volume = {98},
number = {1175},
pages = {1834--1842},
doi = {10.1093/bjr/tqaf075}
}
EUVIMED