Clinical utility of non-gated 4-min delayed dual-energy CT for myocardial extracellular volume quantification
British Journal of Radiology · 2025
DOI: 10.1093/bjr/tqaf022 ↗Kurz gefasst
Fachartikel in der Zeitschrift British Journal of Radiology, 2025. Verfasst von Tsukasa Kojima und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, Fukuoka, 812-8582, Japan. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Heart, Myocardium. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 26 Literaturangaben.
Abstract (Originalsprache)
Objectives
To develop and validate the myocardial extracellular volume (ECV) obtained from non-electrocardiography (ECG)-gated delayed CT images acquired 4 min post-contrast infusion (4-min-non-ECG-ECV) compared with the ECV obtained from ECG-gated delayed CT images acquired 10 min post-contrast infusion (Conv-ECV).
Methods
We retrospectively analysed 29 patients (males: 21) after a comprehensive CT protocol of both 4-min-non-ECG-ECV and Conv-ECV on a dual-layer CT scanner. The mean volume of contrast medium administered was 90 ± 11.8 mL, and the average heart rate during the CT examinations was 74.2 ± 18.2 bpm. Two independent observers calculated the respective 4-min-non-ECG-ECV and Conv-ECV. We determined the correlation between the ECV obtained by the 2 methods and conducted a Bland-Altman analysis to identify systematic errors and determine the limits of agreement (LOA) between the 4-min-non-ECG-ECV and Conv-ECV values.
Results
The respective median ECV values for observer 1 were 27.3 for 4-min-non-ECG-ECV and 26.5 for Conv-ECV; for observer 2, they were 27.8 and 27.1. The correlation between the methods was 0.97 for both observers (P < .01). The Bland-Altman plots for observers 1 and 2 demonstrated a minor bias (−0.2% and −0.5%, respectively), with the 95% LOA ranges at −4.4% to 4.0% and −5.0% to 4.0%, respectively.
Conclusion
The 4-min-non-ECG-ECV provided ECV values comparable to those obtained by Conv-ECV. Advances in knowledge Myocardial ECV quantification is feasible using a non-gated, 4-min delayed dual-energy CT scan with an already established CT acquisition method. This approach achieves ECV accuracy comparable to that of the conventional CT-ECV calculation method (gated 10-min delayed imaging) while enhancing clinical efficacy and diagnostic throughput.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, Fukuoka, 812-8582, Japan.
- Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, 812-8582, Japan.
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, 812-8582, Japan.
ORCID-Profile: Tsukasa Kojima, Yuzo Yamasaki
Zitieren
APA
Kojima, T., Yamasaki, Y., Nishigake, D., Shirasaka, T., Kondo, M., Hioki, K., Kamitani, T., Kato, T., & Ishigami, K. (2025). Clinical utility of non-gated 4-min delayed dual-energy CT for myocardial extracellular volume quantification. British Journal of Radiology. https://doi.org/10.1093/bjr/tqaf022
Vancouver
Kojima T, Yamasaki Y, Nishigake D, Shirasaka T, Kondo M, Hioki K, et al. Clinical utility of non-gated 4-min delayed dual-energy CT for myocardial extracellular volume quantification. British Journal of Radiology. 2025. doi:10.1093/bjr/tqaf022
BibTeX
@article{Kojima2025,
author = {Kojima, Tsukasa and Yamasaki, Yuzo and Nishigake, Daisuke and Shirasaka, Takashi and Kondo, Masatoshi and Hioki, Kazuhito and Kamitani, Takeshi and Kato, Toyoyuki and Ishigami, Kousei},
title = {Clinical utility of non-gated 4-min delayed dual-energy CT for myocardial extracellular volume quantification},
journal = {British Journal of Radiology},
year = {2025},
doi = {10.1093/bjr/tqaf022}
}
EUVIMED