EUVIMEDEUVIMED entdecken
QuerschnittstudieOpen Access · CC BY 4.0

Value of projectional imaging relative to cross-sectional imaging to assess catheter tip position in the superior vena cava: evaluation of reader variability

Giuseppe Gullo iD, David Christian Rotzinger, Pierre Frossard, Anaïs Colin, Guillaume Saliou iD, Salah Dine Qanadli

British Journal of Radiology · 2025

DOI: 10.1093/bjr/tqae218 ↗

Kurz gefasst

Querschnittstudie in der Zeitschrift British Journal of Radiology, 2025. Verfasst von Giuseppe Gullo und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Radiology, University Hospital, 1011 Lausanne, Switzerland. Hauptthemen laut MEDLINE: Vena Cava, Superior, Catheterization, Central Venous, Tomography, X-Ray Computed, Central Venous Catheters. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Lausanne University, Consortium of Swiss Academic Libraries.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

The cavo-atrial junction (CAJ) is the most appropriate central venous catheters CVC tip location to reduce complications. Among chest X-ray (CXR) landmarks for tips assessment, only the pericardial reflection lies in the same plane as the vascular structures. We aimed to evaluate the observer variability to determine tip positioning on CXR, using CT as a gold standard.

Methods

We retrospectively analyzed 107 CT scans of patients with port catheters (January–December 2021). The tip to CAJ distance (DCAJ) was measured on both projectional (PJ) and cross-sectional (CS) CT images by 2 × 2 observers (within and between evaluations). Observational statistics included paired t-tests, repeatability coefficients (RC), and intraclass correlation coefficients (ICC), with data visualized using Bland-Altman plots.

Results

All ICC were >0.9, indicating excellent reliability. The mean difference between observers comparing CS and PJ was 0.13 ± 0.80 cm (P = .10) with outer 95% confidence limits of 1.92 cm and −2.17 cm and an RC of 1.79 cm.

Conclusion

CXR provides a reliable method for CVC tip localization, though assessment variability is ±2 cm. Advances in knowledge CXR assessment of CVC tips shows both intra- and inter-individual variability, due to challenges in identifying the CAJ and catheter tip . While considering the 3 cm anatomical zone around the CAJ acceptable, operators should be aware of the 2 cm variability resulting from CXR assessment. To account for this variability and avoid the risk of positioning the tip beyond 3 cm from the CAJ, operators should reduce the CXR-based acceptable zone to 1 cm around the CAJ, impacting approximately 30% of procedures.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Vena Cava, SuperiorCatheterization, Central VenousTomography, X-Ray ComputedCentral Venous CathetersHumansRetrospective StudiesFemaleMaleMiddle AgedReproducibility of ResultsObserver VariationAgedAdultAged, 80 and over

Stichwörter der Autor:innen

X-ray computedcentral venous cathetersconsensusobserver variationradiographysuperiorthoracictomography scannersvena cava

Autor:innen und Institutionen

  • Department of Diagnostic and Interventional Radiology, University Hospital, 1011 Lausanne, Switzerland.
  • Faculty of Biology and Medicine (FBM), University of Lausanne (UNIL), 1015 Lausanne, Switzerland.

ORCID-Profile: Giuseppe Gullo, Guillaume Saliou

Förderung

  • Lausanne University
  • Consortium of Swiss Academic Libraries

Zitieren

APA

Gullo, G., Rotzinger, D. C., Frossard, P., Colin, A., Saliou, G., & Qanadli, S. D. (2025). Value of projectional imaging relative to cross-sectional imaging to assess catheter tip position in the superior vena cava: evaluation of reader variability. British Journal of Radiology. https://doi.org/10.1093/bjr/tqae218

Vancouver

Gullo G, Rotzinger DC, Frossard P, Colin A, Saliou G, Qanadli SD. Value of projectional imaging relative to cross-sectional imaging to assess catheter tip position in the superior vena cava: evaluation of reader variability. British Journal of Radiology. 2025. doi:10.1093/bjr/tqae218

BibTeX
@article{Gullo2025,
  author = {Gullo, Giuseppe and Rotzinger, David Christian and Frossard, Pierre and Colin, Anaïs and Saliou, Guillaume and Qanadli, Salah Dine},
  title = {Value of projectional imaging relative to cross-sectional imaging to assess catheter tip position in the superior vena cava: evaluation of reader variability},
  journal = {British Journal of Radiology},
  year = {2025},
  doi = {10.1093/bjr/tqae218}
}
Kostenlos starten →