Fixed rate vs fixed injection duration in single-pass contrast-enhanced abdominal multi-detector CT: effects on vascular enhancement
British Journal of Radiology · 2025
DOI: 10.1093/bjr/tqae202 ↗Kurz gefasst
Fachartikel in der Zeitschrift British Journal of Radiology, 2025. Verfasst von Luigi Camera und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Advanced Biomedical Sciences-Section of Radiology, University "Federico II", Via S. Pansini 5 - 80131 Naples, Italy. Hauptthemen laut MEDLINE: Contrast Media. Die Arbeit nennt 35 Literaturangaben.
Abstract (Originalsprache)
Objectives
To evaluate the effects on vascular enhancement of either a fixed rate (FR) or a fixed injection duration (FID) in single-pass (SP) contrast-enhanced abdominal multi-detector CT (CE-MDCT).
Methods
Ninety-nine (54 M; 45 F; aged 18-86 years) patients with nontraumatic acute abdomen underwent a SP CE-MDCT after i.v. injection of 1.7 cc/Kg of a nonionic iodinated contrast media (370 mgI/mL) performed with either a FR (2 cc/s; Group A) or a FID (55 s; Group B). In both groups, patients were further stratified according to total body weight (kg) as follows: 40-60 (L); 61-80 (M); 81-100 (H). Signal- (SNR) and contrast-to-noise ratios (CNR) were calculated for the liver and for both abdominal aorta (AA) and main portal vein (MPV). Statistical analysis was performed by Student t- or Chi-square test for continuous and categorical data, respectively, whereas post hoc analysis was performed by the Mann-Whitney test (P < .05).
Results
There were no significant differences in demographic and physical characteristics between Group A (n = 50; 53 ± 20 years; BMI = 23.4 ± 4.4) and Group B (n = 50; 51 ± 17 years; BMI 22.7 ± 4.2). Whereas overlapping findings were observed in the M sub-groups (n = 40), SNR and CNR were significantly higher (P < .01) in Group B for both AA and MPV in the high (H) weight sub-groups (n = 20) while not significant differences were observed in the low (L) weight sub-groups (n = 40) despite a significantly lower injection rate (1.6 ± 0.2 cc/s, P < .01) in Group B.
Conclusion
A FID results in an overall better vascular enhancement than a FR in SP CE-MDCT. Advances in knowledge Single-pass is an optimized contrast-enhanced abdominal CT protocol combining the benefits of vascular and visceral enhancement and characterized by a customized scan delay tailored around a monophasic contrast injection. In single-pass protocol, a fixed injection duration (55 s) results in an overall better vascular enhancement than a fixed rate (2 cc/s) and should be therefore regarded as the injection modality of choice.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Advanced Biomedical Sciences-Section of Radiology, University "Federico II", Via S. Pansini 5 - 80131 Naples, Italy.
- Institute of Biostructures and Bioimaging (National Research Council), 80131 Naples, Italy.
ORCID-Profile: Luigi Camera
Zitieren
APA
Camera, L., D'Ambrosio, V., Pinto, L., Paludi, A., Liuzzi, R., De Cicco, R., Ponsiglione, A., Lagnese, M. G., Maurea, S., & Brunetti, A. (2025). Fixed rate vs fixed injection duration in single-pass contrast-enhanced abdominal multi-detector CT: effects on vascular enhancement. British Journal of Radiology. https://doi.org/10.1093/bjr/tqae202
Vancouver
Camera L, D'Ambrosio V, Pinto L, Paludi A, Liuzzi R, De Cicco R, et al. Fixed rate vs fixed injection duration in single-pass contrast-enhanced abdominal multi-detector CT: effects on vascular enhancement. British Journal of Radiology. 2025. doi:10.1093/bjr/tqae202
BibTeX
@article{Camera2025,
author = {Camera, Luigi and D'Ambrosio, Vincenzo and Pinto, Lorenzo and Paludi, Adriana and Liuzzi, Raffaele and De Cicco, Rossella and Ponsiglione, Andrea and Lagnese, Maria Grazia and Maurea, Simone and Brunetti, Arturo},
title = {Fixed rate vs fixed injection duration in single-pass contrast-enhanced abdominal multi-detector CT: effects on vascular enhancement},
journal = {British Journal of Radiology},
year = {2025},
doi = {10.1093/bjr/tqae202}
}
EUVIMED