EUVIMEDEUVIMED entdecken
Crossref

Fixed rate vs fixed injection duration in single-pass contrast-enhanced abdominal multi-detector CT: effects on vascular enhancement

Luigi Camera iD, Vincenzo D'Ambrosio, Lorenzo Pinto, Adriana Paludi, Raffaele Liuzzi, Rossella De Cicco, Andrea Ponsiglione, Maria Grazia Lagnese, Simone Maurea, Arturo Brunetti

British Journal of Radiology · 2025

DOI: 10.1093/bjr/tqae202 ↗

Kurz gefasst

Fachartikel in der Zeitschrift British Journal of Radiology, 2025. Verfasst von Luigi Camera und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Advanced Biomedical Sciences-Section of Radiology, University "Federico II", Via S. Pansini 5 - 80131 Naples, Italy. Hauptthemen laut MEDLINE: Contrast Media. Die Arbeit nennt 35 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To evaluate the effects on vascular enhancement of either a fixed rate (FR) or a fixed injection duration (FID) in single-pass (SP) contrast-enhanced abdominal multi-detector CT (CE-MDCT).

Methods

Ninety-nine (54 M; 45 F; aged 18-86 years) patients with nontraumatic acute abdomen underwent a SP CE-MDCT after i.v. injection of 1.7 cc/Kg of a nonionic iodinated contrast media (370 mgI/mL) performed with either a FR (2 cc/s; Group A) or a FID (55 s; Group B). In both groups, patients were further stratified according to total body weight (kg) as follows: 40-60 (L); 61-80 (M); 81-100 (H). Signal- (SNR) and contrast-to-noise ratios (CNR) were calculated for the liver and for both abdominal aorta (AA) and main portal vein (MPV). Statistical analysis was performed by Student t- or Chi-square test for continuous and categorical data, respectively, whereas post hoc analysis was performed by the Mann-Whitney test (P < .05).

Results

There were no significant differences in demographic and physical characteristics between Group A (n = 50; 53 ± 20 years; BMI = 23.4 ± 4.4) and Group B (n = 50; 51 ± 17 years; BMI 22.7 ± 4.2). Whereas overlapping findings were observed in the M sub-groups (n = 40), SNR and CNR were significantly higher (P < .01) in Group B for both AA and MPV in the high (H) weight sub-groups (n = 20) while not significant differences were observed in the low (L) weight sub-groups (n = 40) despite a significantly lower injection rate (1.6 ± 0.2 cc/s, P < .01) in Group B.

Conclusion

A FID results in an overall better vascular enhancement than a FR in SP CE-MDCT. Advances in knowledge Single-pass is an optimized contrast-enhanced abdominal CT protocol combining the benefits of vascular and visceral enhancement and characterized by a customized scan delay tailored around a monophasic contrast injection. In single-pass protocol, a fixed injection duration (55 s) results in an overall better vascular enhancement than a fixed rate (2 cc/s) and should be therefore regarded as the injection modality of choice.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Contrast MediaHumansMiddle AgedAgedAdultMaleFemaleAged, 80 and overAdolescentYoung AdultMultidetector Computed TomographyAorta, AbdominalAbdomen, AcuteInjections, IntravenousPortal VeinRadiographic Image EnhancementRadiography, AbdominalLiver

Stichwörter der Autor:innen

CT protocolcontrast injectionimage qualityiodine delivery ratescan delay

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Department of Advanced Biomedical Sciences-Section of Radiology, University "Federico II", Via S. Pansini 5 - 80131 Naples, Italy.
  • Institute of Biostructures and Bioimaging (National Research Council), 80131 Naples, Italy.

ORCID-Profile: Luigi Camera

Zitieren

APA

Camera, L., D'Ambrosio, V., Pinto, L., Paludi, A., Liuzzi, R., De Cicco, R., Ponsiglione, A., Lagnese, M. G., Maurea, S., & Brunetti, A. (2025). Fixed rate vs fixed injection duration in single-pass contrast-enhanced abdominal multi-detector CT: effects on vascular enhancement. British Journal of Radiology. https://doi.org/10.1093/bjr/tqae202

Vancouver

Camera L, D'Ambrosio V, Pinto L, Paludi A, Liuzzi R, De Cicco R, et al. Fixed rate vs fixed injection duration in single-pass contrast-enhanced abdominal multi-detector CT: effects on vascular enhancement. British Journal of Radiology. 2025. doi:10.1093/bjr/tqae202

BibTeX
@article{Camera2025,
  author = {Camera, Luigi and D'Ambrosio, Vincenzo and Pinto, Lorenzo and Paludi, Adriana and Liuzzi, Raffaele and De Cicco, Rossella and Ponsiglione, Andrea and Lagnese, Maria Grazia and Maurea, Simone and Brunetti, Arturo},
  title = {Fixed rate vs fixed injection duration in single-pass contrast-enhanced abdominal multi-detector CT: effects on vascular enhancement},
  journal = {British Journal of Radiology},
  year = {2025},
  doi = {10.1093/bjr/tqae202}
}
Kostenlos starten →