EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Assessment of interstitial lung disease in a systemic sclerosis patient cohort using photon-counting detector CT with ultra-high resolution and a 1024-pixel image matrix

Lisa Jungblut iD, Thomas Sartoretti, Anna Landsmann, Dominik Nakhostin, Toni Rabadi, Victor Mergen, Suzana Jordan, Carmen-Marina Mihai, Oliver Dister iD, Thomas Frauenfelder, Katharina Martini

British Journal of Radiology · 2024

DOI: 10.1093/bjr/tqae170 ↗

Kurz gefasst

Fachartikel in der Zeitschrift British Journal of Radiology, 2024. Verfasst von Lisa Jungblut und 10 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, CH-8091 Zurich, Switzerland. Hauptthemen laut MEDLINE: Lung Diseases, Interstitial, Scleroderma, Systemic, Tomography, X-Ray Computed. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: European Society of Thoracic Imaging.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

This study assessed the potential of ultra-high resolution (UHR) and a 1024-matrix in photon-counting-detector CT (PCD-CT) for evaluating interstitial lung disease (ILD) in systemic sclerosis (SSc) patients.

Methods

Sixty-six SSc patients who underwent ILD-CT screening on a first-generation PCD-CT were retrospectively included. Scans were performed in UHR mode at 100 kVp with two different matrix sizes (512×512 and 1024x1024) and reconstructed at slice thicknesses of 1.5 and 0.2 mm. Image noise, subjective image quality, and ILD changes (ground glass opacities and reticulations) were evaluated on a 5-point Likert-scale by two independent readers.

Results

Interreader agreement for subjective image quality ranged from fair to almost perfect (Krippendorff-Alpha: 0.258-0.862). Overall image quality was highest for 1.5 mm/1024 matrix images [(reader 1: 4(4.4), reader 2: 5(4.5)]. Image sharpness was rated significantly better in 0.2 mm images (P < .001). Regarding ILD changes, 0.2 mm slice thickness outperformed 1.5 mm slice thickness significantly (P < .001), while there was no significant difference between the two matrix sizes. A 1024-matrix size demonstrated superiority in evaluating coarse reticulations compared to 512-matrix size.

Conclusion

UHR mode with a 0.2 mm slice thickness showed enhanced image sharpness and improved visibility of ILD changes compared to standard reconstructions. This has the potential to enable the early detection of subtle disease manifestations. Advances in knowledge With the invention of PCD-CT different reconstruction algorithms need to be evaluated for specific pathologies. In our study ILD UHR mode with 0.2 mm slice thickness showed to be beneficial in the detection of parenchymal changes in patients with scleroderma.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lung Diseases, InterstitialScleroderma, SystemicTomography, X-Ray ComputedHumansFemaleRetrospective StudiesMaleMiddle AgedAgedAdultRadiographic Image Interpretation, Computer-AssistedPhotonsLung

Stichwörter der Autor:innen

CTchestinterstitial lung diseasepulmonary fibrosissystemic sclerosis

Autor:innen und Institutionen

  • Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, CH-8091 Zurich, Switzerland.
  • Department of Rheumatology, University Hospital Zurich, University of Zurich, CH-8091 Zurich, Switzerland.

ORCID-Profile: Lisa Jungblut, Oliver Dister

Förderung

  • European Society of Thoracic Imaging

Zitieren

APA

Jungblut, L., Sartoretti, T., Landsmann, A., Nakhostin, D., Rabadi, T., Mergen, V., Jordan, S., Mihai, C. M., Dister, O., Frauenfelder, T., & Martini, K. (2024). Assessment of interstitial lung disease in a systemic sclerosis patient cohort using photon-counting detector CT with ultra-high resolution and a 1024-pixel image matrix. British Journal of Radiology. https://doi.org/10.1093/bjr/tqae170

Vancouver

Jungblut L, Sartoretti T, Landsmann A, Nakhostin D, Rabadi T, Mergen V, et al. Assessment of interstitial lung disease in a systemic sclerosis patient cohort using photon-counting detector CT with ultra-high resolution and a 1024-pixel image matrix. British Journal of Radiology. 2024. doi:10.1093/bjr/tqae170

BibTeX
@article{Jungblut2024,
  author = {Jungblut, Lisa and Sartoretti, Thomas and Landsmann, Anna and Nakhostin, Dominik and Rabadi, Toni and Mergen, Victor and Jordan, Suzana and Mihai, Carmen-Marina and Dister, Oliver and Frauenfelder, Thomas and Martini, Katharina},
  title = {Assessment of interstitial lung disease in a systemic sclerosis patient cohort using photon-counting detector CT with ultra-high resolution and a 1024-pixel image matrix},
  journal = {British Journal of Radiology},
  year = {2024},
  doi = {10.1093/bjr/tqae170}
}
Kostenlos starten →