Downgrading Breast Imaging Reporting and Data System categories in ultrasound using strain elastography and computer-aided diagnosis system: a multicenter, prospective study
British Journal of Radiology · 2024
DOI: 10.1093/bjr/tqae136 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift British Journal of Radiology, 2024. Verfasst von Yu Du und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasound, Shanghai General Hospital, Shanghai Jiaotong University School of Medicine, Shanghai 200080, China. Hauptthemen laut MEDLINE: Elasticity Imaging Techniques, Ultrasonography, Mammary, Breast Neoplasms, Diagnosis, Computer-Assisted. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: National Natural Science Foundation of China, Science and Technology Commission of Shanghai Municipality.
Abstract (Originalsprache)
Objective
To determine whether adding elastography strain ratio (SR) and a deep learning based computer-aided diagnosis (CAD) system to breast ultrasound (US) can help reclassify Breast Imaging Reporting and Data System (BI-RADS) 3 and 4a-c categories and avoid unnecessary biopsies.
Methods
This prospective, multicentre study included 1049 masses (691 benign, 358 malignant) with assigned BI-RADS 3 and 4a-c between 2020 and 2022. CAD results was dichotomized possibly malignant vs. benign. All patients underwent SR and CAD examinations and histopathological findings were the standard of reference. Reduction of unnecessary biopsies (biopsies in benign lesions) and missed malignancies after reclassified (new BI-RADS 3) with SR and CAD were the outcome measures.
Results
Following the routine conventional breast US assessment, 48.6% (336 of 691 masses) underwent unnecessary biopsies. After reclassifying BI-RADS 4a masses (SR cut-off <2.90, CAD dichotomized possibly benign), 25.62% (177 of 691 masses) underwent an unnecessary biopsies corresponding to a 50.14% (177 vs. 355) reduction of unnecessary biopsies. After reclassification, only 1.72% (9 of 523 masses) malignancies were missed in the new BI-RADS 3 group.
Conclusion
Adding SR and CAD to clinical practice may show an optimal performance in reclassifying BI-RADS 4a to 3 categories, and 50.14% masses would be benefit by keeping the rate of undetected malignancies with an acceptable value of 1.72%. Advances in knowledge Leveraging the potential of SR in conjunction with CAD holds immense promise in substantially reducing the biopsy frequency associated with BI-RADS 3 and 4A lesions, thereby conferring substantial advantages upon patients encompassed within this cohort.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ultrasound, Shanghai General Hospital, Shanghai Jiaotong University School of Medicine, Shanghai 200080, China.
- Department of Ultrasound, Jiangsu Cancer Hospital & Jiangsu Institute of Cancer, Research & The Affiliated Cancer Hospital of Nanjing Medical University, Nanjing 210009, China.
- Department of Ultrasound, The First Affiliated Hospital of Nanjing Medical University, Nanjing 210029, China.
ORCID-Profile: Yu Du, Ji Ma, Tingting Wu, Fang Li, Jiazhen Pan, Liwen Du, Manqi Zhang, Xuehong Diao, Rong Wu
Förderung
- National Natural Science Foundation of China
- Science and Technology Commission of Shanghai Municipality
Zitieren
APA
Du, Y., Ma, J., Wu, T., Li, F., Pan, J., Du, L., Zhang, M., Diao, X., & Wu, R. (2024). Downgrading Breast Imaging Reporting and Data System categories in ultrasound using strain elastography and computer-aided diagnosis system: a multicenter, prospective study. British Journal of Radiology. https://doi.org/10.1093/bjr/tqae136
Vancouver
Du Y, Ma J, Wu T, Li F, Pan J, Du L, et al. Downgrading Breast Imaging Reporting and Data System categories in ultrasound using strain elastography and computer-aided diagnosis system: a multicenter, prospective study. British Journal of Radiology. 2024. doi:10.1093/bjr/tqae136
BibTeX
@article{Du2024,
author = {Du, Yu and Ma, Ji and Wu, Tingting and Li, Fang and Pan, Jiazhen and Du, Liwen and Zhang, Manqi and Diao, Xuehong and Wu, Rong},
title = {Downgrading Breast Imaging Reporting and Data System categories in ultrasound using strain elastography and computer-aided diagnosis system: a multicenter, prospective study},
journal = {British Journal of Radiology},
year = {2024},
doi = {10.1093/bjr/tqae136}
}
EUVIMED