EUVIMEDEUVIMED entdecken
Open Access

Improved stent sharpness evaluation with super-resolution deep learning reconstruction in coronary CT angiography

Jae-Kyun Ryu, Ki Hwan Kim, Chuluunbaatar Otgonbaatar iD, Da Som Kim, Hackjoon Shim, Jung Wook Seo iD

British Journal of Radiology · 2024

DOI: 10.1093/bjr/tqae094 ↗

Kurz gefasst

Fachartikel in der Zeitschrift British Journal of Radiology, 2024. Verfasst von Jae-Kyun Ryu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Medical Imaging AI Research Center, Canon Medical Systems Korea, Seoul, Republic of Korea. Hauptthemen laut MEDLINE: Deep Learning, Computed Tomography Angiography, Coronary Angiography, Stents. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: BRACCO Research Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

This study aimed to assess the impact of super-resolution deep learning reconstruction (SR-DLR) on coronary CT angiography (CCTA) image quality and blooming artifacts from coronary artery stents in comparison to conventional methods, including hybrid iterative reconstruction (HIR) and deep learning-based reconstruction (DLR).

Methods

A retrospective analysis included 66 CCTA patients from July to November 2022. Major coronary arteries were evaluated for image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). Stent sharpness was quantified using 10%-90% edge rise slope (ERS) and 10%-90% edge rise distance (ERD). Qualitative analysis employed a 5-point scoring system to assess overall image quality, image noise, vessel wall, and stent structure.

Results

SR-DLR demonstrated significantly lower image noise compared to HIR and DLR. SNR and CNR were notably higher in SR-DLR. Stent ERS was significantly improved in SR-DLR, with mean ERD values of 0.70 ± 0.20 mm for SR-DLR, 1.13 ± 0.28 mm for HIR, and 0.85 ± 0.26 mm for DLR. Qualitatively, SR-DLR scored higher in all categories.

Conclusions

SR-DLR produces images with lower image noise, leading to improved overall image quality, compared with HIR and DLR. SR-DLR is a valuable image reconstruction algorithm for enhancing the spatial resolution and sharpness of coronary artery stents without being constrained by hardware limitations. Advances in knowledge The overall image quality was significantly higher in SR-DLR, resulting in sharper coronary artery stents compared to HIR and DLR.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep LearningComputed Tomography AngiographyCoronary AngiographyStentsSignal-To-Noise RatioHumansRetrospective StudiesMaleFemaleMiddle AgedAgedCoronary VesselsArtifactsRadiographic Image Interpretation, Computer-AssistedCoronary Artery Disease

Stichwörter der Autor:innen

coronary CT angiographycoronary stentdeep learning reconstructionhybrid iterative reconstructionsuper-resolution deep learning reconstruction

Autor:innen und Institutionen

  • Medical Imaging AI Research Center, Canon Medical Systems Korea, Seoul, Republic of Korea.
  • Department of Radiology, Inje University Ilsan Paik Hospital, Inje University College of Medicine, Goyang, Republic of Korea.
  • Department of Radiology, Seoul National University College of Medicine, Seoul, Republic of Korea.
  • Department of Radiology, Inje University Busan Paik Hospital, Inje University College of Medicine, Busan, Republic of Korea.
  • ConnectAI Research Center, Yonsei University College of Medicine, Seoul, Republic of Korea.

ORCID-Profile: Chuluunbaatar Otgonbaatar, Jung Wook Seo

Förderung

  • BRACCO Research Foundation

Zitieren

APA

Ryu, J. K., Kim, K. H., Otgonbaatar, C., Kim, D. S., Shim, H., & Seo, J. W. (2024). Improved stent sharpness evaluation with super-resolution deep learning reconstruction in coronary CT angiography. British Journal of Radiology. https://doi.org/10.1093/bjr/tqae094

Vancouver

Ryu JK, Kim KH, Otgonbaatar C, Kim DS, Shim H, Seo JW. Improved stent sharpness evaluation with super-resolution deep learning reconstruction in coronary CT angiography. British Journal of Radiology. 2024. doi:10.1093/bjr/tqae094

BibTeX
@article{Ryu2024,
  author = {Ryu, Jae-Kyun and Kim, Ki Hwan and Otgonbaatar, Chuluunbaatar and Kim, Da Som and Shim, Hackjoon and Seo, Jung Wook},
  title = {Improved stent sharpness evaluation with super-resolution deep learning reconstruction in coronary CT angiography},
  journal = {British Journal of Radiology},
  year = {2024},
  doi = {10.1093/bjr/tqae094}
}
Kostenlos starten →