EUVIMEDEUVIMED entdecken
Crossref

CD12 Contact dermatitis unmasked: facial allergic contact dermatitis associated with a light-emitting diode face mask

Farlin Asharaff, Livia Francine Soriano

British Journal of Dermatology · 26.06.2026 · 195 (Supplement_1)

DOI: 10.1093/bjd/ljag086.337 ↗

Kurz gefasst

Fachartikel in der Zeitschrift British Journal of Dermatology, online erschienen am 13.11.2026. Verfasst von Farlin Asharaff und 1 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Light-emitting diode (LED) face masks are increasingly used for cosmetic and antiageing purposes and often involve prolonged, repeated face contact. While nickel and cobalt are well-­recognized causes of allergic contact dermatitis (ACD), the role of LED cosmetic devices as potential sources of contact allergens remains under-recognized. A 45-year-old woman was referred for patch testing following a 3-month history of severe erythematous and oedematous dermatitis affecting the forehead, cheeks and peri­oral region. Although the eruption had resolved by the time of patch testing, review of clinical photographs demonstrated a sharply demarcated, mask-shaped distribution, prompting targeted history taking, which identified daily use of an LED face mask for approximately 2 months immediately prior to symptom onset. Discontinuation of the device resulted in desquamation and complete resolution over several weeks. Rechallenge led to recurrence of face dermatitis within 48 h, predominantly affecting the upper cheeks. Following permanent cessation, she was treated for postinflammatory hyperpigmentation. In addition, she reported a history suggestive of ACD to metals in costume jewellery and to gel nail products, both of which she had avoided. Patch testing using the British Society of Cutaneous Allergy baseline and extended series, including metals, cosmetics and rubber haptens, demonstrated strong positive reactions to nickel(Ii) sulfate hexahydrate 5% petrolatum (++), cobalt(Ii) chloride hexahydrate 1% petrolatum (+++) and 2-hydroxyethyl methacrylate 2% petrolatum (+). Metal components within LED face masks include internal circuitry, charging contact points and, in this device, cooling elements. The mask-shaped distribution closely mirrored areas of device contact, supporting the LED face mask as a clinically relevant exposure. This case highlights an association between facial allergic contact dermatitis and LED face mask use. As use of cosmetic devices continues to expand, clinicians should consider a broader range of device-related exposures when evaluating patients presenting with facial dermatitis.

Zitieren

APA

Asharaff, F., & Soriano, L. F. (2026). CD12 Contact dermatitis unmasked: facial allergic contact dermatitis associated with a light-emitting diode face mask. British Journal of Dermatology, 195(Supplement_1). https://doi.org/10.1093/bjd/ljag086.337

Vancouver

Asharaff F, Soriano LF. CD12 Contact dermatitis unmasked: facial allergic contact dermatitis associated with a light-emitting diode face mask. British Journal of Dermatology. 2026;195(Supplement_1). doi:10.1093/bjd/ljag086.337

BibTeX
@article{Asharaff2026,
  author = {Asharaff, Farlin and Soriano, Livia Francine},
  title = {CD12 Contact dermatitis unmasked: facial allergic contact dermatitis associated with a light-emitting diode face mask},
  journal = {British Journal of Dermatology},
  year = {2026},
  volume = {195},
  number = {Supplement_1},
  doi = {10.1093/bjd/ljag086.337}
}
Kostenlos starten →