RED Protocol: Ultrasound for Intraoperative Detection of Pneumothorax and Hemothorax in Rib Remodeling Surgeries
Aesthetic Surgery Journal · 29.10.2026
DOI: 10.1093/asj/sjag245 ↗Kurz gefasst
Studienprotokoll in der Zeitschrift Aesthetic Surgery Journal, online erschienen am 29.10.2026. Verfasst von Hugo A Aguilar und 14 weiteren Autor:innen. Beteiligte Einrichtung: Private practice in Bogota, Colombia.
Abstract (Originalsprache)
Background
Ribcage remodeling procedures are increasingly used in aesthetic surgery to reduce waist circumference; however, they carry a potential risk of pneumothorax and hemothorax due to proximity to the lung parenchyma. Early intraoperative detection of these complications is critical but currently not standardized.
Objectives
To evaluate the feasibility and diagnostic performance of the Rib Complication Evaluation and Detection (RED) protocol, an intraoperative ultrasound-based approach for detecting pneumothorax and hemothorax during ribcage remodeling procedures.
Methods
A retrospective observational study was conducted including 113 patients undergoing ribcage remodeling between 2023 and 2024. Due to the low incidence of pneumothorax, the protocol was additionally assessed using 250 high-fidelity simulation scenarios with the CAE Vimedix system. Ultrasound findings were standardized, and sensitivity, specificity, and predictive values were calculated.
Results
No cases of pneumothorax or hemothorax were identified in the clinical cohort. In simulation testing, the RED protocol demonstrated a sensitivity of 96% and specificity of 100% for pneumothorax detection, with a positive predictive value of 100% and a negative predictive value of 98%. The protocol successfully differentiated pneumothorax from other thoracic conditions.
Conclusions
The RED protocol provides a structured and reproducible approach for intraoperative lung ultrasound in ribcage remodeling. While simulation was necessary due to the low prevalence of complications, the protocol is based on well-established sonographic signs. Its high negative predictive value suggests utility as a rule-out tool, enhancing intraoperative safety. Further prospective studies are needed to validate its performance in real clinical scenarios.
Autor:innen und Institutionen
- Private practice in Bogota, Colombia.
- Universidad el bosque, Bogota, Colombia.
- Plastic surgeon in private practice in Bogota, Colombia.
- Private practice in Bucaramanga, Colombia.
- Private practice in São Paulo, Brazil.
- Private practice in Loja, Ecuador.
ORCID-Profile: Alfredo E Hoyos, Mauricio Perez, Brian Ramirez
Zitieren
APA
Aguilar, H. A., Velasco, M., Reyes, L. F., Echeverry, N. G., Hoyos, A. E., Villabona, S. J., Serrano, H. M., Proto, R., Oñate Valdivieso, D., Oñate Valdivieso, C., Diaz, C. J., Peña-Pinzon, W., Perez, M., Varela, A., & Ramirez, B. (2026). RED Protocol: Ultrasound for Intraoperative Detection of Pneumothorax and Hemothorax in Rib Remodeling Surgeries. Aesthetic Surgery Journal. https://doi.org/10.1093/asj/sjag245
Vancouver
Aguilar HA, Velasco M, Reyes LF, Echeverry NG, Hoyos AE, Villabona SJ, et al. RED Protocol: Ultrasound for Intraoperative Detection of Pneumothorax and Hemothorax in Rib Remodeling Surgeries. Aesthetic Surgery Journal. 2026. doi:10.1093/asj/sjag245
BibTeX
@article{Aguilar2026,
author = {Aguilar, Hugo A and Velasco, Manuel and Reyes, Luis F and Echeverry, Nicole G and Hoyos, Alfredo E and Villabona, Silvia J and Serrano, Hector M and Proto, Ricardo and Oñate Valdivieso, Daniel and Oñate Valdivieso, Carlos and Diaz, Cristian J and Peña-Pinzon, William and Perez, Mauricio and Varela, Agustina and Ramirez, Brian},
title = {RED Protocol: Ultrasound for Intraoperative Detection of Pneumothorax and Hemothorax in Rib Remodeling Surgeries},
journal = {Aesthetic Surgery Journal},
year = {2026},
doi = {10.1093/asj/sjag245}
}
EUVIMED