Prepectoral Direct-to-Implant Breast Reconstruction Without Acellular Dermal Matrice or Mesh: A Prospective Single-Surgeon Series of 210 Patients and 349 Breasts
Aesthetic Surgery Journal · 2026
DOI: 10.1093/asj/sjag191 ↗Kurz gefasst
Fachartikel in der Zeitschrift Aesthetic Surgery Journal, 2026. Verfasst von Burcu Celet Ozden und 6 weiteren Autor:innen. Hauptthemen laut MEDLINE: Breast Implants, Breast Implantation, Postoperative Complications. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background
Prepectoral breast reconstruction reduces postoperative morbidity and eliminates animation deformity. Although acellular dermal matrices (ADMs) and mesh have traditionally been utilized to stabilize prepectoral implants, emerging evidence has questioned their value and highlighted their association with postoperative complications.
Objectives
This study presents a single-surgeon experience using 4-micron surface implants without ADM or mesh in immediate prepectoral direct-to-implant reconstruction.
Methods
This is a prospective, single-center, single-surgeon study involving patients who underwent immediate prepectoral, breast reconstruction using Motiva Ergonomix2 implants, between September 2023 and March 2025. Early and mid-term complications, aesthetic outcomes, and patient-reported satisfaction (BREAST-Q) were analyzed.
Results
A total of 210 consecutive patients (349 breasts) underwent this surgical procedure with a median follow-up of 12 months (range, 3-21 months). Early complications occurred in 26.1% of breasts, most commonly incision dehiscence (5.2%), hematoma (3.7%), and partial nipple–areola complex necrosis (2.9%). Capsular contracture (Grade III-IV) occurred in 7.7% and implant rippling in 6%. Twenty-eight breasts (8%) required unplanned reoperation. Total implant loss occurred in 1.1% of breasts. Cosmetic outcomes (n = 143) were rated “excellent” or “good” in >75% of cases, approaching 92% in bilateral prophylactic mastectomies. BREAST-Q responses (n = 129) demonstrated a postoperative breast satisfaction score of 64.96% and implant satisfaction of 6.6/8.
Conclusions
This technique demonstrates low complication and implant loss rates, satisfactory aesthetic results, and high patient-reported satisfaction. These findings support Ergonomix2 implants as a safe, biocompatible, and potentially cost-effective option for prepectoral reconstruction. Level of Evidence: 2 (Therapeutic)
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
ORCID-Profile: Burcu Celet Ozden, Tugba Gun Koplay
Zitieren
APA
Celet Ozden, B., Aytaş Sevindik, G., Yildirim, N., Yilmaz, C., Karanlik, H., Gun Koplay, T., & Igci, A. (2026). Prepectoral Direct-to-Implant Breast Reconstruction Without Acellular Dermal Matrice or Mesh: A Prospective Single-Surgeon Series of 210 Patients and 349 Breasts. Aesthetic Surgery Journal. https://doi.org/10.1093/asj/sjag191
Vancouver
Celet Ozden B, Aytaş Sevindik G, Yildirim N, Yilmaz C, Karanlik H, Gun Koplay T, et al. Prepectoral Direct-to-Implant Breast Reconstruction Without Acellular Dermal Matrice or Mesh: A Prospective Single-Surgeon Series of 210 Patients and 349 Breasts. Aesthetic Surgery Journal. 2026. doi:10.1093/asj/sjag191
BibTeX
@article{CeletOzden2026,
author = {Celet Ozden, Burcu and Aytaş Sevindik, Gamze and Yildirim, Nilufer and Yilmaz, Cem and Karanlik, Hasan and Gun Koplay, Tugba and Igci, Abdullah},
title = {Prepectoral Direct-to-Implant Breast Reconstruction Without Acellular Dermal Matrice or Mesh: A Prospective Single-Surgeon Series of 210 Patients and 349 Breasts},
journal = {Aesthetic Surgery Journal},
year = {2026},
doi = {10.1093/asj/sjag191}
}
EUVIMED