EUVIMEDEUVIMED entdecken
Crossref

Accuracy of High-Frequency Ultrasonography, Computed Tomography, and MRI in Detecting Ruptured Silicone Breast Implants

Xiaoying Mao, Ziming Zhang, Ying Jia, Li Yuan, Hongli Chai, Jintian Hu

Aesthetic Surgery Journal · 06.05.2026

DOI: 10.1093/asj/sjag093 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Aesthetic Surgery Journal, online erschienen am 06.05.2026. Verfasst von Xiaoying Mao und 5 weiteren Autor:innen. Beteiligte Einrichtung: Radiology Department, Plastic Surgery Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China. Die Arbeit nennt 22 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Breast implant rupture is a common complication, but the diagnostic efficacy of MRI, high-frequency ultrasonography (HFUS), and computed tomography (CT) in breast implant rupture has not been fully explored.

Objectives

This study aimed to evaluate the effectiveness of MRI, HFUS, and CT for detecting breast implant rupture.

Methods

Data were collected retrospectively from medical records of our hospital between December 2022 and September 2025. Patients were categorized into intact and ruptured implant groups. Imaging features of breast implant rupture were detected using HFUS, CT, and MRI.

Results

We included 157 women with bilateral breast implants (n = 314). HFUS detected rupture in 19% (n = 60) of implants, CT in 21% (n = 55), and MRI in 23% (n = 26). Surgical findings revealed ruptures in 25% (n = 43) of implants. HFUS demonstrated the high overall performance in detecting breast implant rupture, with a diagnostic accuracy of 91%, sensitivity of 81%. Implant duration was significantly longer for ruptured implants than for intact implants (P < .05). For each additional year after implantation, the likelihood of rupture increased 1.19-fold. HFUS findings differed significantly between ruptured and intact implants. Abnormal ultrasound signs should raise high suspicion of implant rupture.

Conclusions

Our findings confirm that HFUS, CT, and MRI each display distinct characteristics of breast implant rupture, with HFUS demonstrating favorable diagnostic performance. Abnormal ultrasound findings should raise strong suspicion of rupture. Because the risk of rupture increases with longer implant duration, we recommend earlier and more frequent HFUS examinations. Level of Evidence: 4 (Risk) For image description, please refer to the figure legend and surrounding text.

Autor:innen und Institutionen

  • Radiology Department, Plastic Surgery Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
  • Department of Ear Reconstruction, Plastic Surgery Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
  • Department of Ultrasound, Plastic Surgery Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
  • Department of Cosmetic Injection Center, Plastic Surgery Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.

Zitieren

APA

Mao, X., Zhang, Z., Jia, Y., Yuan, L., Chai, H., & Hu, J. (2026). Accuracy of High-Frequency Ultrasonography, Computed Tomography, and MRI in Detecting Ruptured Silicone Breast Implants. Aesthetic Surgery Journal. https://doi.org/10.1093/asj/sjag093

Vancouver

Mao X, Zhang Z, Jia Y, Yuan L, Chai H, Hu J. Accuracy of High-Frequency Ultrasonography, Computed Tomography, and MRI in Detecting Ruptured Silicone Breast Implants. Aesthetic Surgery Journal. 2026. doi:10.1093/asj/sjag093

BibTeX
@article{Mao2026,
  author = {Mao, Xiaoying and Zhang, Ziming and Jia, Ying and Yuan, Li and Chai, Hongli and Hu, Jintian},
  title = {Accuracy of High-Frequency Ultrasonography, Computed Tomography, and MRI in Detecting Ruptured Silicone Breast Implants},
  journal = {Aesthetic Surgery Journal},
  year = {2026},
  doi = {10.1093/asj/sjag093}
}
Kostenlos starten →