EUVIMEDEUVIMED entdecken
Vergleichsstudie

Efficacy and Safety of Microwave Energy–Based Device for Facial Rejuvenation: A Retrospective Comparative Study With High-Intensity Focused Ultrasound

Ha Jong Nam iD, Namju Cheon, Yean Su Choi, Hee Yong Kang, Se Young Kim, Hwan Jun Choi

Aesthetic Surgery Journal · 2026

DOI: 10.1093/asj/sjaf264 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Aesthetic Surgery Journal, 2026. Verfasst von Ha Jong Nam und 5 weiteren Autor:innen. Hauptthemen laut MEDLINE: Rejuvenation, Skin Aging, Microwaves, High-Intensity Focused Ultrasound Ablation. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: National Research Foundation of Korea, Korean government, Ministry of Science and ICT.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Facial aging is characterized by soft tissue atrophy, subcutaneous fat redistribution, and dermal laxity, most pronounced in the lower face and submental region. High-intensity focused ultrasound (HIFU) is the benchmark noninvasive lifting modality, whereas microwave energy–based devices (MEBDs) have recently emerged, targeting adipose tissue and dermis. Although MEBD has been validated in body contouring, evidence for facial efficacy and safety remains limited.

Objectives

This study aimed to compare the efficacy and safety of MEBD and HIFU for facial rejuvenation in an East Asian population, emphasizing temporal improvement patterns, tolerability, and adverse events.

Methods

The authors retrospectively analyzed 171 patients (MEBD: n = 89; HIFU: n = 82) treated at a single institution. MEBD used 7 and 3 mm handpieces for subcutaneous lipolysis and dermal tightening, guided by fat-compartment mapping. HIFU applied 600 shots at 3.0 and 4.5 mm depths targeting the dermis and superficial musculoaponeurotic system. Outcomes included blinded evaluator Global Aesthetic Improvement Scale (GAIS), Cutometer elasticity, Facial Aesthetic Surgery Outcome Questionnaire (FACE-Q) satisfaction, pain, and adverse events, assessed at baseline, 1 month, and 3 months.

Results

MEBD showed greater early improvements in GAIS, Cutometer parameters (R2, R5), and FACE-Q scores at 1 month, with lower pain (2.3 vs 4.7, P < .001) and fewer adverse events. By 3 months, HIFU surpassed MEBD in sustained GAIS, FACE-Q, and elasticity gains. Both modalities were safe, with only mild, transient effects.

Conclusions

MEBD demonstrated rapid onset, superior tolerability, and lower complication rates, whereas HIFU provided stronger long-term lifting and elasticity improvements. These findings support complementary clinical roles and a compartment-based rationale for facial MEBD. Level of Evidence: 3 (Therapeutic)

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RejuvenationSkin AgingMicrowavesHigh-Intensity Focused Ultrasound AblationCosmetic TechniquesHumansRetrospective StudiesFemaleMiddle AgedMaleTreatment OutcomeAdultPatient SatisfactionFaceAgedSubcutaneous Fat

Autor:innen und Institutionen

ORCID-Profile: Ha Jong Nam

Förderung

  • National Research Foundation of Korea
  • Korean government
  • Ministry of Science and ICT
  • Soonchunhyang University

Zitieren

APA

Nam, H. J., Cheon, N., Choi, Y. S., Kang, H. Y., Kim, S. Y., & Choi, H. J. (2026). Efficacy and Safety of Microwave Energy–Based Device for Facial Rejuvenation: A Retrospective Comparative Study With High-Intensity Focused Ultrasound. Aesthetic Surgery Journal. https://doi.org/10.1093/asj/sjaf264

Vancouver

Nam HJ, Cheon N, Choi YS, Kang HY, Kim SY, Choi HJ. Efficacy and Safety of Microwave Energy–Based Device for Facial Rejuvenation: A Retrospective Comparative Study With High-Intensity Focused Ultrasound. Aesthetic Surgery Journal. 2026. doi:10.1093/asj/sjaf264

BibTeX
@article{Nam2026,
  author = {Nam, Ha Jong and Cheon, Namju and Choi, Yean Su and Kang, Hee Yong and Kim, Se Young and Choi, Hwan Jun},
  title = {Efficacy and Safety of Microwave Energy–Based Device for Facial Rejuvenation: A Retrospective Comparative Study With High-Intensity Focused Ultrasound},
  journal = {Aesthetic Surgery Journal},
  year = {2026},
  doi = {10.1093/asj/sjaf264}
}
Kostenlos starten →