Long-term Follow-up of Remnant Capsules After Implant Removal Without Capsulectomy: An Animal Model Study
Aesthetic Surgery Journal · 2025
DOI: 10.1093/asj/sjaf089 ↗Kurz gefasst
Fachartikel in der Zeitschrift Aesthetic Surgery Journal, 2025. Verfasst von Jaewoo Kim und 4 weiteren Autor:innen. Hauptthemen laut MEDLINE: Breast Implants, Device Removal, Breast Implantation, Silicone Gels. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Technology Innovation Program, Ministry of Trade, Industry and Energy.
Abstract (Originalsprache)
Background
Breast implantation induces fibrous capsule formation as a natural foreign body response. Although capsule-related complications often require capsulectomy, the need for capsulectomy during implant removal in patients with asymptomatic capsules remains unclear.
Objectives
In this study, the authors aim to examine the capsule's degradation process over time and identify key cytokines involved in its remodeling.
Methods
Nine 7-week-old Sprague–Dawley rats received custom 2.25 cm silicone cohesive gel implants subcutaneously on both dorsal sides. Capsule tissues were collected at implant removal (0M) and 3-month (3M) and 6-month (6M) intervals following implant removal without capsulectomy. Tissues were analyzed histologically utilizing hematoxylin and eosin and Masson's trichrome staining. Immunohistochemical staining for matrix metalloproteinase-9 (MMP9), CD31, α-smooth muscle actin (αSMA), Type I collagen (COL1), and CD68 was quantified for comparative analysis.
Results
The 0M group showed robust capsule formation with dense collagen and myofibroblasts. Over time, the capsules thinned (315 µm at 0M, 194.8 µm at 3M, 136.8 µm at 6M; P < .01), became structurally disrupted, and merged with surrounding adipose tissue. Notably, MMP9 and CD31 levels increased significantly, indicating enhanced matrix turnover and vascularization. αSMA and COL1 declined initially before partially rebounding at 6M, whereas CD68 exhibited trends consistent with ongoing remodeling.
Conclusions
The findings illustrate the natural degradation and remodeling of implant-induced capsules driven by specific cytokines and matrix markers. These insights may inform future guidelines on the necessity of capsulectomy during implant removal.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Förderung
- Technology Innovation Program
- Ministry of Trade, Industry and Energy
Zitieren
APA
Kim, J., Yang, H., Cho, J., Hong, K. Y., & Chang, H. (2025). Long-term Follow-up of Remnant Capsules After Implant Removal Without Capsulectomy: An Animal Model Study. Aesthetic Surgery Journal. https://doi.org/10.1093/asj/sjaf089
Vancouver
Kim J, Yang H, Cho J, Hong KY, Chang H. Long-term Follow-up of Remnant Capsules After Implant Removal Without Capsulectomy: An Animal Model Study. Aesthetic Surgery Journal. 2025. doi:10.1093/asj/sjaf089
BibTeX
@article{Kim2025,
author = {Kim, Jaewoo and Yang, Heewoong and Cho, Jeongmok and Hong, Ki Yong and Chang, Hak},
title = {Long-term Follow-up of Remnant Capsules After Implant Removal Without Capsulectomy: An Animal Model Study},
journal = {Aesthetic Surgery Journal},
year = {2025},
doi = {10.1093/asj/sjaf089}
}
EUVIMED