Robotic Repair: An Alternative Technique for Rectus Diastasis and Abdominal Bulge Following DIEP Flap Breast Reconstruction
Aesthetic Surgery Journal · 2024
DOI: 10.1093/asj/sjae059 ↗Kurz gefasst
Fachartikel in der Zeitschrift Aesthetic Surgery Journal, 2024. Verfasst von Kaila Herold und 6 weiteren Autor:innen. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Mammaplasty, Perforator Flap, Rectus Abdominis. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 26 Literaturangaben.
Abstract (Originalsprache)
Background
The deep inferior epigastric artery perforator (DIEP) flap is the gold standard in autologous breast reconstruction. Despite advances in perforator dissection, abdominal morbidity still occurs. Traditional rectus diastasis (RD), abdominal bulge, and hernia repair with open techniques are associated with higher complication rates and recurrence.
Objectives
We present a novel case series of robotic repair of symptomatic RD and/or abdominal bulge with concurrent hernia following DIEP flap surgery.
Methods
A single-center, retrospective review was conducted of 10 patients who underwent bilateral DIEP flap breast reconstruction and subsequent robotic repair of RD and/or abdominal bulge and hernia. Preoperative demographics and postoperative clinical outcomes were reviewed. RD up to 5 cm, abdominal bulge, and any concurrent ventral/umbilical hernias were repaired robotically with retrorectus plication and macroporous mesh reinforcement.
Results
The average age and BMI were 49 years (range 41-63) and 31 kg/m2 (range 26-44), respectively. The average number of perforators harvested per flap was 2.5 (range 1-4). Average RD and hernia size were 3.95 cm (range 2-5) and 5.8 cm2 (1-15), respectively. Eight patients stayed 1 night in the hospital, and 2 went home the same day as the robotic repair. No patients were converted to open technique and none experienced complications within 30 days.
Conclusions
For patients who experience donor site morbidity following DIEP flap breast reconstruction, minimally invasive robotic repair of RD and/or abdominal bulge with hernia can be performed with mesh reinforcement. This technique is effective, with low complication rates, and should be considered over open repair. Level of Evidence: 4
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
ORCID-Profile: Kaila Herold
Zitieren
APA
Herold, K., Stoddard, T., Rodriguez-Unda, N., LoGiudice, J., Hettinger, P., Higgins, R. M., & Doren, E. L. (2024). Robotic Repair: An Alternative Technique for Rectus Diastasis and Abdominal Bulge Following DIEP Flap Breast Reconstruction. Aesthetic Surgery Journal. https://doi.org/10.1093/asj/sjae059
Vancouver
Herold K, Stoddard T, Rodriguez-Unda N, LoGiudice J, Hettinger P, Higgins RM, et al. Robotic Repair: An Alternative Technique for Rectus Diastasis and Abdominal Bulge Following DIEP Flap Breast Reconstruction. Aesthetic Surgery Journal. 2024. doi:10.1093/asj/sjae059
BibTeX
@article{Herold2024,
author = {Herold, Kaila and Stoddard, Timothy and Rodriguez-Unda, Nelson and LoGiudice, John and Hettinger, Patrick and Higgins, Rana M and Doren, Erin L},
title = {Robotic Repair: An Alternative Technique for Rectus Diastasis and Abdominal Bulge Following DIEP Flap Breast Reconstruction},
journal = {Aesthetic Surgery Journal},
year = {2024},
doi = {10.1093/asj/sjae059}
}
EUVIMED