EUVIMEDEUVIMED entdecken
Crossref

Augmented Safety Profile of Ultrasound-Guided Gluteal Fat Transfer: Retrospective Study With 1815 Patients

Natalia Vidal-Laureano, Carlos T Huerta, Eduardo A Perez, Steven Alexander Earle

Aesthetic Surgery Journal · 15.03.2024 · 44 (4) · NP263-NP270

DOI: 10.1093/asj/sjad377 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Aesthetic Surgery Journal, online erschienen am 20.12.2023. Verfasst von Natalia Vidal-Laureano und 3 weiteren Autor:innen. Hauptthemen laut MEDLINE: Lipectomy, Embolism, Fat. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 31 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Gluteal augmentation with autologous fat transfer is one of the fastest growing aesthetic surgical procedures worldwide over the past decade. However, this procedure can be associated with high mortality from fatal pulmonary fat embolism events caused by intramuscular injection of fat. Ultrasound-guided fat grafting allows visualization of the transfer in the subcutaneous space, avoiding intramuscular injection.

Objectives

The aim of this study was to assess the safety and efficacy of gluteal fat grafting performed with ultrasound-guided cannulation.

Methods

A retrospective chart review of all patients undergoing ultrasound-guided gluteal fat grafting at the authors’ center between 2019 and 2022 was performed. All cases were performed by board-certified and board-eligible plastic surgeons under general anesthesia in ASA Class I or II patients. Fat was only transferred to the subcutaneous plane when over the gluteal muscle. Patients underwent postoperative follow-up from a minimum of 3 months up to 2 years. Results were analyzed with standard statistical tests.

Results

The study encompassed 1815 female patients with a median age of 34 years. Controlled medical comorbidities were present in 14%, with the most frequent being hypothyroidism (0.7%), polycystic ovarian syndrome (0.7%), anxiety (0.6%), and asthma (0.6%). Postoperative complications occurred in 4% of the total cohort, with the most common being seroma (1.2%), local skin ischemia (1.2%), and surgical site infection (0.8%). There were no macroscopic fat emboli complications or mortalities.

Conclusions

These data suggest that direct visualization of anatomic plane injection through ultrasound guidance is associated with a low rate of complications. Ultrasound guidance is an efficacious adjunct to gluteal fat grafting and is associated with an improved safety profile that should be considered by every surgeon performing this procedure. Level of Evidence: 3

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LipectomyEmbolism, FatHumansFemaleAdultAdipose TissueRetrospective StudiesButtocksUltrasonography, Interventional

Zitieren

APA

Vidal-Laureano, N., Huerta, C. T., Perez, E. A., & Earle, S. A. (2024). Augmented Safety Profile of Ultrasound-Guided Gluteal Fat Transfer: Retrospective Study With 1815 Patients. Aesthetic Surgery Journal, 44(4), NP263-NP270. https://doi.org/10.1093/asj/sjad377

Vancouver

Vidal-Laureano N, Huerta CT, Perez EA, Earle SA. Augmented Safety Profile of Ultrasound-Guided Gluteal Fat Transfer: Retrospective Study With 1815 Patients. Aesthetic Surgery Journal. 2024;44(4):NP263-NP270. doi:10.1093/asj/sjad377

BibTeX
@article{VidalLaureano2024,
  author = {Vidal-Laureano, Natalia and Huerta, Carlos T and Perez, Eduardo A and Earle, Steven Alexander},
  title = {Augmented Safety Profile of Ultrasound-Guided Gluteal Fat Transfer: Retrospective Study With 1815 Patients},
  journal = {Aesthetic Surgery Journal},
  year = {2024},
  volume = {44},
  number = {4},
  pages = {NP263--NP270},
  doi = {10.1093/asj/sjad377}
}
Kostenlos starten →