EUVIMEDEUVIMED entdecken
Crossref

Estimating the time-varying emission rate of peracetic acid

Ryan Hines iD, Chun-Yu Chen iD, Mark Nicas iD, Gurumurthy Ramachandran iD

Annals of Work Exposures and Health · 2025

DOI: 10.1093/annweh/wxae100 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Annals of Work Exposures and Health, 2025. Verfasst von Ryan Hines und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Environmental Health and Engineering, Bloomberg School of Public Health, Johns Hopkins University, 615 N Wolfe St, Baltimore, MD 21205,…. Hauptthemen laut MEDLINE: Peracetic Acid, Environmental Monitoring, Disinfectants, Occupational Exposure. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 25 Literaturangaben. Gefördert von: NIOSH CDC HHS, U.S. Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health to the Johns Hopkins Education and Research Center for Occupational Safety and Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The use of peracetic acid (PAA) as a general disinfectant has seen increasing usage in recent years, and although it is a strong irritant, exposure monitoring for PAA may often be difficult due to relatively high costs and the potential for interferences by other co-occurring chemicals such as hydrogen peroxide. These issues with exposure monitoring make modeling a potentially useful tool in exposure assessment of PAA if model parameters can be accurately determined. This study estimates the time-varying mass emission rate of PAA for use in exposure modeling by using the small spill model and examines the effect of various environmental conditions on the PAA evaporation rate, including surface roughness/substrate, general ventilation rate, and local wind speed. The relatively high evaporation rate constant (1.18 min−1) determined did not vary significantly with these parameters, suggesting it is applicable across a wide range of common environmental conditions. In addition, in a controlled chamber setting, the first-order decay rate constant for PAA in air was determined to be 0.5 h−1. The corresponding half-life of 83 min is approximately 4 times longer than previous estimates. This decay rate should be accounted for in future modeling and exposure assessments. To evaluate the estimated evaporation rate, trials were conducted in a highly controlled exposure chamber using conditions similar to those found in healthcare settings to compare predicted modeled concentrations to those made by a real-time detection instrument, SafeCide 2.0 (ChemDAQ, Inc.). The results of the trials indicate that the evaporation rate constant and well-mixed room model perform well in predicting the concentration of PAA over a range of conditions. Moreover, the modeling results and measured concentrations across all trials indicate a high potential for overexposure to PAA. Therefore, exposure controls must be adequate when considering the use of PAA as a general disinfectant.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Peracetic AcidEnvironmental MonitoringDisinfectantsOccupational ExposureAir Pollutants, OccupationalHumansTime Factors

Stichwörter der Autor:innen

evaporation rate constantexposure chamberexposure modelingexposure to disinfectant chemicalsmass emission rateperacetic acidsurface roughnessventilation ratewind speed

Substanzen

Peracetic AcidDisinfectantsAir Pollutants, Occupational

Autor:innen und Institutionen

  • Department of Environmental Health and Engineering, Bloomberg School of Public Health, Johns Hopkins University, 615 N Wolfe St, Baltimore, MD 21205, United States.
  • Department of Environmental and Occupational Health, College of Medicine, National Cheng Kung University, Tainan 70403, Taiwan.
  • School of Public Health, University of California, Berkeley, Berkeley, CA 94720-7360, United States.

ORCID-Profile: Ryan Hines, Chun-Yu Chen, Mark Nicas, Gurumurthy Ramachandran

Förderung

  • NIOSH CDC HHS
  • U.S. Centers for Disease Control and Prevention
  • National Institute for Occupational Safety and Health to the Johns Hopkins Education and Research Center for Occupational Safety and Health
  • NIOSH

Zitieren

APA

Hines, R., Chen, C. Y., Nicas, M., & Ramachandran, G. (2025). Estimating the time-varying emission rate of peracetic acid. Annals of Work Exposures and Health. https://doi.org/10.1093/annweh/wxae100

Vancouver

Hines R, Chen CY, Nicas M, Ramachandran G. Estimating the time-varying emission rate of peracetic acid. Annals of Work Exposures and Health. 2025. doi:10.1093/annweh/wxae100

BibTeX
@article{Hines2025,
  author = {Hines, Ryan and Chen, Chun-Yu and Nicas, Mark and Ramachandran, Gurumurthy},
  title = {Estimating the time-varying emission rate of peracetic acid},
  journal = {Annals of Work Exposures and Health},
  year = {2025},
  doi = {10.1093/annweh/wxae100}
}