Determining whether barcodes on investigational compounded sterile products are scannable by an IV workflow management system
American Journal of Health-System Pharmacy · 10.06.2026
DOI: 10.1093/ajhp/zxag165 ↗Kurz gefasst
Fachartikel in der Zeitschrift American Journal of Health-System Pharmacy, online erschienen am 10.06.2026. Verfasst von Jennifer Panich und 3 weiteren Autor:innen. Beteiligte Einrichtung: Investigational Drug Services, Froedtert and the Medical College of Wisconsin, Milwaukee, WI, USA. Die Arbeit nennt 13 Literaturangaben.
Abstract (Originalsprache)
Purpose
The goals of this project were to determine (1) what proportion of compounded sterile product investigational products (CSP IPs) stocked by our institution’s investigational drug service have barcodes, and (2) whether CSP IPs that do have barcodes contain a number that is usable by our institution’s IV workflow management system. A secondary goal was to determine sponsor willingness to embed a drug identifier in the barcodes. Summary A survey of the site’s inventory was conducted to identify CSP IPs. The vials were examined to determine if they contained a barcode, and if so, scanning was performed to determine what number was embedded in each barcode. In addition, sponsors of vials with barcodes were queried about whether they would be willing to embed a drug identifier, while sponsors with no barcodes were queried about their willingness to add barcodes.
Conclusion
The study found that 66.9% of the CSP IP vials contained barcodes. However, the numbers embedded in the barcodes on most of these IPs varied from vial to vial. The structure of the numbers embedded in each barcode did not match the GS1-128 structure seen on FDA-approved products, and there was no usable drug identifier in any barcode in the opinion of the team’s informatics pharmacist.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Investigational Drug Services, Froedtert and the Medical College of Wisconsin, Milwaukee, WI, USA.
- Inpatient Pharmacy, Froedtert and the Medical College of Wisconsin, Milwaukee, WI, USA.
- Pharmacy Informatics, Froedtert and the Medical College of Wisconsin, Milwaukee, WI, USA.
Zitieren
APA
Panich, J., Awad, D., Waggoner, M., & Hallam, M. (2026). Determining whether barcodes on investigational compounded sterile products are scannable by an IV workflow management system. American Journal of Health-System Pharmacy. https://doi.org/10.1093/ajhp/zxag165
Vancouver
Panich J, Awad D, Waggoner M, Hallam M. Determining whether barcodes on investigational compounded sterile products are scannable by an IV workflow management system. American Journal of Health-System Pharmacy. 2026. doi:10.1093/ajhp/zxag165
BibTeX
@article{Panich2026,
author = {Panich, Jennifer and Awad, Doha and Waggoner, Mindy and Hallam, Mike},
title = {Determining whether barcodes on investigational compounded sterile products are scannable by an IV workflow management system},
journal = {American Journal of Health-System Pharmacy},
year = {2026},
doi = {10.1093/ajhp/zxag165}
}
EUVIMED