EUVIMEDEUVIMED entdecken
Crossref

Utilizing a real-world data set to assess titration practices for high-alert medications delivered via continuous infusions with smart infusion pumps

Jose Nery, Rita Jew, Michelle Mandrack, Joanne Hatfield, Sean O'Neill

American Journal of Health-System Pharmacy · 2025

DOI: 10.1093/ajhp/zxaf297 ↗

Kurz gefasst

Fachartikel in der Zeitschrift American Journal of Health-System Pharmacy, 2025. Verfasst von Jose Nery und 4 weiteren Autor:innen. Beteiligte Einrichtung: Hospital of the University of Pennsylvania, Philadelphia, PA, USA. Hauptthemen laut MEDLINE: Infusion Pumps, Medication Errors. Die Arbeit nennt 11 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Smart infusion pumps provide dose error reduction systems (DERS) designed to intercept dosing and/or programming errors; however, DERS may not be able to capture all potential errors. Through analyzing the logged activity data of these devices, valuable insights for dose titration practices and risks during administration of high-alert continuous infusions can be determined.

Methods

Data were extracted from the Bainbridge Health Infusion Pump Network for the period of January through December 2022. Continuous infusions for adult patients of common, titratable, high-alert medications were selected.

Results

Data from the Bainbridge Health Infusion Pump Network, comprising 20 health systems across the US, yielded 347,170 infusions for analysis. The 9 medications identified for review were dexmedetomidine, dobutamine, fentanyl, heparin, insulin, midazolam, norepinephrine, propofol, and vasopressin. Data for 1% of infusions were suggestive of 10-fold dose programming errors, 1% of infusions exceeded suggested maximum doses, and infusions of 4 out of the 9 medications were often titrated too quickly.

Conclusion

This first-of-its-kind data analysis identified safety gaps that can help establish greater standardization of appropriate titration parameters for high-alert medications. These standards can further optimize drug libraries and enhance DERS to increase medication safety in the use of smart infusion pumps.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Infusion PumpsMedication ErrorsHumansInfusions, Intravenous

Stichwörter der Autor:innen

dose error reduction systemsdose titrationhigh-alert medication errorinfusion pumpsmedical device safetymedication errors

Autor:innen und Institutionen

  • Hospital of the University of Pennsylvania, Philadelphia, PA, USA.
  • Institute for Safe Medication Practices, Plymouth Meeting, PA, USA.
  • Bainbridge Health, Philadelphia, PA, USA.

Zitieren

APA

Nery, J., Jew, R., Mandrack, M., Hatfield, J., & O'Neill, S. (2025). Utilizing a real-world data set to assess titration practices for high-alert medications delivered via continuous infusions with smart infusion pumps. American Journal of Health-System Pharmacy. https://doi.org/10.1093/ajhp/zxaf297

Vancouver

Nery J, Jew R, Mandrack M, Hatfield J, O'Neill S. Utilizing a real-world data set to assess titration practices for high-alert medications delivered via continuous infusions with smart infusion pumps. American Journal of Health-System Pharmacy. 2025. doi:10.1093/ajhp/zxaf297

BibTeX
@article{Nery2025,
  author = {Nery, Jose and Jew, Rita and Mandrack, Michelle and Hatfield, Joanne and O'Neill, Sean},
  title = {Utilizing a real-world data set to assess titration practices for high-alert medications delivered via continuous infusions with smart infusion pumps},
  journal = {American Journal of Health-System Pharmacy},
  year = {2025},
  doi = {10.1093/ajhp/zxaf297}
}
Kostenlos starten →