Effect of a patient-specific QTc alert on decreasing prescribing of QTc-prolonging medications in outpatients
American Journal of Health-System Pharmacy · 2025
DOI: 10.1093/ajhp/zxaf283 ↗Kurz gefasst
Fachartikel in der Zeitschrift American Journal of Health-System Pharmacy, 2025. Verfasst von Christopher R Zimmerman und 2 weiteren Autor:innen. Beteiligte Einrichtung: Health Information and Technology Services, Michigan Medicine, Ann Arbor, MI, and Department of Pharmacy, University of Michigan, Ann Arbor, MI, USA. Hauptthemen laut MEDLINE: Long QT Syndrome, Medical Order Entry Systems, Decision Support Systems, Clinical. Die Arbeit nennt 16 Literaturangaben.
Abstract (Originalsprache)
Purpose
Previous studies have shown decreased exposure to QTc-prolonging medications through utilization of a clinical decision support (CDS) alert in the electronic health record (EHR) in hospitalized patients. Minimization of risk factors, including exposure to QTc-prolonging medications, is important to decrease the risk of adverse outcomes, including ventricular arrhythmias. This study evaluated the effect of a patient-specific prolonged QTc EHR alert in nonhospitalized patients.
Methods
This was a single-center, retrospective, quasi-experimental pre-post analysis of an interruptive alert that is triggered in adult nonhospitalized patients upon entry of an order for a QTc-prolonging medication for patients with the following QTc criteria: (1) QTc of ≥500 ms or QTc of <550 ms with QRS of ≤130 ms without bundle branch block and not atrio-ventricular dual or ventricular paced or (2) QTc of >550 ms. Pre- and post-alert groups were compared for the primary outcome of the number of QTc-prolonging medication orders entered.
Results
The alert significantly decreased the number of orders for QTc-prolonging medications (odds ratio, 0.0017; 95% confidence interval, 0.0001-0.0281; P < 0.001). The alert override rate was 50%. No patients in either group had documentation of torsades de pointes.
Conclusion
This study demonstrated that an interruptive EHR alert at the time of order entry can decrease exposure to QTc-prolonging medications and potentially decrease the risk for ventricular arrhythmias in nonhospitalized patients with a prolonged QTc interval. Further research is needed to determine whether integration of other patient-specific parameters into the CDS alert would improve its potential to lower the risk of QTc-related adverse outcomes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Health Information and Technology Services, Michigan Medicine, Ann Arbor, MI, and Department of Pharmacy, University of Michigan, Ann Arbor, MI, USA.
- Department of Clinical Pharmacy, Michigan Medicine, Ann Arbor, MI, USA.
- Division of Cardiovascular Medicine, Department of Internal Medicine, Michigan Medicine, Ann Arbor, MI, USA.
Zitieren
APA
Zimmerman, C. R., Adie, S., & Bhave, N. M. (2025). Effect of a patient-specific QTc alert on decreasing prescribing of QTc-prolonging medications in outpatients. American Journal of Health-System Pharmacy. https://doi.org/10.1093/ajhp/zxaf283
Vancouver
Zimmerman CR, Adie S, Bhave NM. Effect of a patient-specific QTc alert on decreasing prescribing of QTc-prolonging medications in outpatients. American Journal of Health-System Pharmacy. 2025. doi:10.1093/ajhp/zxaf283
BibTeX
@article{Zimmerman2025,
author = {Zimmerman, Christopher R and Adie, Sarah and Bhave, Nicole M},
title = {Effect of a patient-specific QTc alert on decreasing prescribing of QTc-prolonging medications in outpatients},
journal = {American Journal of Health-System Pharmacy},
year = {2025},
doi = {10.1093/ajhp/zxaf283}
}
EUVIMED