Implementation and evaluation of an EHR-integrated perpetual inventory system in a large tertiary hospital oncology pharmacy
American Journal of Health-System Pharmacy · 11.06.2024 · 81 (12) · 546-554
DOI: 10.1093/ajhp/zxae022 ↗Kurz gefasst
Fachartikel in der Zeitschrift American Journal of Health-System Pharmacy, online erschienen am 31.01.2024. Verfasst von Luning Shi und 3 weiteren Autor:innen. Beteiligte Einrichtung: Houston Methodist Hospital, Houston, TX, USA. Hauptthemen laut MEDLINE: Tertiary Care Centers, Pharmacy Service, Hospital, Electronic Health Records. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 11 Literaturangaben.
Abstract (Originalsprache)
Purpose
This study aimed to compare the impact of an electronic health record (EHR)–integrated perpetual inventory management system (EIMS) versus a traditional inventory management system (TIMS) on inventory accuracy, visibility, and turnover in a large academic tertiary hospital.
Methods
The quasi-experimental study was conducted over 12 months (a 6-month preimplementation period and a 6-month postimplementation period, with an 11-month washout period) at Houston Methodist Hospital. The EIMS was implemented following the use of a TIMS. A total of 114 matched inventory items from both systems were identified and compared. The primary outcome was inventory accuracy, calculated as cycle count accuracy. The secondary outcomes were inventory visibility and monthly inventory turnover rate.
Results
Analysis demonstrated a 6.02% absolute increase in inventory accuracy (P < 0.001) with use of the EIMS versus the TIMS. After adjusting for inflation, there was an increase in the captured cost of goods sold from $4.16 million to $5.16 million. The monthly inventory value, adjusted for inflation in the prices of studied inventory items, increased from $2.05 million to $2.33 million. The monthly inventory turnover rate increased from 2.03 to 2.23 turns per month (P = 0.305) when comparing data for the pre- and postimplementation periods. Inventory visibility increased from 133 inventory items to 264 inventory items after EIMS implementation, indicating a 98% visibility increase compared to preimplementation levels.
Conclusion
This study found that implementing an EIMS significantly increased pharmacy inventory accuracy and inventory visibility, which are essential for optimizing patient care and pharmacy financial management.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Houston Methodist Hospital, Houston, TX, USA.
Zitieren
APA
Shi, L., Wei, W., Smith, A., & Abbasi, G. (2024). Implementation and evaluation of an EHR-integrated perpetual inventory system in a large tertiary hospital oncology pharmacy. American Journal of Health-System Pharmacy, 81(12), 546-554. https://doi.org/10.1093/ajhp/zxae022
Vancouver
Shi L, Wei W, Smith A, Abbasi G. Implementation and evaluation of an EHR-integrated perpetual inventory system in a large tertiary hospital oncology pharmacy. American Journal of Health-System Pharmacy. 2024;81(12):546-554. doi:10.1093/ajhp/zxae022
BibTeX
@article{Shi2024,
author = {Shi, Luning and Wei, Wenfei and Smith, Adam and Abbasi, Ghalib},
title = {Implementation and evaluation of an EHR-integrated perpetual inventory system in a large tertiary hospital oncology pharmacy},
journal = {American Journal of Health-System Pharmacy},
year = {2024},
volume = {81},
number = {12},
pages = {546--554},
doi = {10.1093/ajhp/zxae022}
}