Utilization of a technology-assisted workflow to prepare controlled substance oral syringes
American Journal of Health-System Pharmacy · 2023
DOI: 10.1093/ajhp/zxad112 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift American Journal of Health-System Pharmacy, 2023. Verfasst von Tina Nester und 5 weiteren Autor:innen. Beteiligte Einrichtung: Wesley Medical Center, Wichita, KS, USA. Hauptthemen laut MEDLINE: Pharmacy Service, Hospital. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 14 Literaturangaben.
Abstract (Originalsprache)
Purpose
Utilization of technology-assisted workflow (TAWF) systems has gained popularity in the sterile compounding setting. This study was designed to evaluate whether safety and efficiency could be seen when preparing oral controlled substance doses gravimetrically vs volumetrically.
Methods
This 2-phase observational study combined manual data collection with automated logs generated by a single TAWF. During phase I, oral controlled substance solutions were prepared volumetrically. In phase II, the same subset of medications was to be prepared gravimetrically via the same TAWF. Findings from phases I and II were compared against each another to determine safety, efficiency, and documentation differences between the volumetric and gravimetric workflows.
Results
Thirteen different medications were evaluated during phase I (1,495 preparations) and phase II (1,781 preparations) of this study. Mean compounding time (min:sec) increased in phase II when compared to phase I (1:49 vs 1:28; P < 0.01), with the deviation detection rate also increasing (7.9% vs 4.7%; P < 0.01). Despite a target in phase II of utilizing gravimetric analysis for more than 80% of preparations, only 45.5% (811 preparations) were prepared with this workflow, as adoption challenges and dose size limitations prevented compliance. Doses that were prepared gravimetrically had a mean accuracy rate of 100.6% (the mean achieved dose was 0.6% higher than the mean prescribed dose) and a rejection rate of 0.99% (compared to the phase I rejection rate of 1.07%; P = 0.67).
Conclusion
The gravimetric workflow provided accuracy and additional safety checks when compared to the volumetric alternative, all while providing users with greater access to data. Health systems should consider staffing, product sourcing, patient populations, and medication safety when determining the balance between volumetric and gravimetric workflows.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Wesley Medical Center, Wichita, KS, USA.
- Becton, Dickinson and Company, San Diego, CA, USA.
Zitieren
APA
Nester, T., Proffitt, K., Anderson, J., Hays, A., Eidem, L., & Greszler, C. (2023). Utilization of a technology-assisted workflow to prepare controlled substance oral syringes. American Journal of Health-System Pharmacy. https://doi.org/10.1093/ajhp/zxad112
Vancouver
Nester T, Proffitt K, Anderson J, Hays A, Eidem L, Greszler C. Utilization of a technology-assisted workflow to prepare controlled substance oral syringes. American Journal of Health-System Pharmacy. 2023. doi:10.1093/ajhp/zxad112
BibTeX
@article{Nester2023,
author = {Nester, Tina and Proffitt, Katrina and Anderson, Jamie and Hays, Amanda and Eidem, Leslie and Greszler, Craig},
title = {Utilization of a technology-assisted workflow to prepare controlled substance oral syringes},
journal = {American Journal of Health-System Pharmacy},
year = {2023},
doi = {10.1093/ajhp/zxad112}
}