EUVIMEDEUVIMED entdecken
Beobachtungsstudie

Utilization of a technology-assisted workflow to prepare controlled substance oral syringes

Tina Nester, Katrina Proffitt, Jamie Anderson, Amanda Hays, Leslie Eidem, Craig Greszler

American Journal of Health-System Pharmacy · 2023

DOI: 10.1093/ajhp/zxad112 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift American Journal of Health-System Pharmacy, 2023. Verfasst von Tina Nester und 5 weiteren Autor:innen. Beteiligte Einrichtung: Wesley Medical Center, Wichita, KS, USA. Hauptthemen laut MEDLINE: Pharmacy Service, Hospital. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 14 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Utilization of technology-assisted workflow (TAWF) systems has gained popularity in the sterile compounding setting. This study was designed to evaluate whether safety and efficiency could be seen when preparing oral controlled substance doses gravimetrically vs volumetrically.

Methods

This 2-phase observational study combined manual data collection with automated logs generated by a single TAWF. During phase I, oral controlled substance solutions were prepared volumetrically. In phase II, the same subset of medications was to be prepared gravimetrically via the same TAWF. Findings from phases I and II were compared against each another to determine safety, efficiency, and documentation differences between the volumetric and gravimetric workflows.

Results

Thirteen different medications were evaluated during phase I (1,495 preparations) and phase II (1,781 preparations) of this study. Mean compounding time (min:sec) increased in phase II when compared to phase I (1:49 vs 1:28; P < 0.01), with the deviation detection rate also increasing (7.9% vs 4.7%; P < 0.01). Despite a target in phase II of utilizing gravimetric analysis for more than 80% of preparations, only 45.5% (811 preparations) were prepared with this workflow, as adoption challenges and dose size limitations prevented compliance. Doses that were prepared gravimetrically had a mean accuracy rate of 100.6% (the mean achieved dose was 0.6% higher than the mean prescribed dose) and a rejection rate of 0.99% (compared to the phase I rejection rate of 1.07%; P = 0.67).

Conclusion

The gravimetric workflow provided accuracy and additional safety checks when compared to the volumetric alternative, all while providing users with greater access to data. Health systems should consider staffing, product sourcing, patient populations, and medication safety when determining the balance between volumetric and gravimetric workflows.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pharmacy Service, HospitalHumansDrug CompoundingWorkflowControlled SubstancesSyringesTechnology

Stichwörter der Autor:innen

controlled substancesdrug compoundingdrug safetynonsterile compoundingpharmacy technologytechnology-assisted workflow

Substanzen

Controlled Substances

Autor:innen und Institutionen

  • Wesley Medical Center, Wichita, KS, USA.
  • Becton, Dickinson and Company, San Diego, CA, USA.

Zitieren

APA

Nester, T., Proffitt, K., Anderson, J., Hays, A., Eidem, L., & Greszler, C. (2023). Utilization of a technology-assisted workflow to prepare controlled substance oral syringes. American Journal of Health-System Pharmacy. https://doi.org/10.1093/ajhp/zxad112

Vancouver

Nester T, Proffitt K, Anderson J, Hays A, Eidem L, Greszler C. Utilization of a technology-assisted workflow to prepare controlled substance oral syringes. American Journal of Health-System Pharmacy. 2023. doi:10.1093/ajhp/zxad112

BibTeX
@article{Nester2023,
  author = {Nester, Tina and Proffitt, Katrina and Anderson, Jamie and Hays, Amanda and Eidem, Leslie and Greszler, Craig},
  title = {Utilization of a technology-assisted workflow to prepare controlled substance oral syringes},
  journal = {American Journal of Health-System Pharmacy},
  year = {2023},
  doi = {10.1093/ajhp/zxad112}
}
Kostenlos starten →