Fachartikel in der Zeitschrift American Journal of Health-System Pharmacy, 2023. Verfasst von Masayoshi Kondo und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pharmacy, Nippon Medical School Tama Nagayama Hospital, Tokyo, Japan. Hauptthemen laut MEDLINE: Analgesics, Opioid, Dexmedetomidine. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 14 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

There is a lack of information on the compatibility of remimazolam with opioid analgesics, muscle relaxants, and other sedatives. This study aimed to evaluate the physical compatibility of remimazolam with these drug classes.

Methods

Remimazolam was combined with 1 or 2 target drugs (remifentanil, fentanyl, rocuronium, vecuronium, dexmedetomidine, and midazolam). Ten physical compatibility tests were conducted, including four 3-drug compatibility tests. Remimazolam was dissolved in 0.9% sodium chloride injection to a final concentration of 5 mg/mL. Other medications were diluted in 0.9% sodium chloride injection to obtain clinically relevant concentrations. Compatibility tests were conducted with 3 test solutions, wherein remimazolam and the target drugs were compounded at equal volume ratios (1:1 or 1:1:1). Visual appearance was assessed and testing of Tyndall effect, turbidity, and pH was performed immediately after mixing and then again 1 hour and 4 hours after mixing. Appearance and turbidity were evaluated by comparison with the control solution of each target drug diluted with 0.9% sodium chloride injection to the same concentration as the test solution.

Results

All drugs tested were determined to be compatible with remimazolam. The drug combination with the highest change of turbidity was remimazolam and vecuronium (a mean increase of 0.16 NTU relative to the remimazolam control solution), 4 hours after mixing. The combination with the highest pH was remimazolam, fentanyl, and vecuronium (mean [SD], 3.76 [0.01]), 4 hours after mixing. The combination of remimazolam and fentanyl showed a larger change in pH at 4 hours after mixing (a mean increase of 2.6%) than immediately after mixing.

Conclusion

Remifentanil, fentanyl, rocuronium, vecuronium, dexmedetomidine, and midazolam are physically compatible with remimazolam during simulated Y-site administration.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Analgesics, OpioidDexmedetomidineHumansDrug IncompatibilityRemifentanilSodium ChlorideAnti-Bacterial AgentsInfusions, IntravenousHypnotics and SedativesMidazolamVecuronium BromideRocuroniumFentanylMusclesBenzodiazepines

Stichwörter der Autor:innen

compatibilitygeneral anesthesiapHremimazolamturbidity

Substanzen

Analgesics, OpioidRemifentanilSodium ChlorideAnti-Bacterial AgentsHypnotics and SedativesMidazolamVecuronium BromideRocuroniumDexmedetomidineFentanyl

Autor:innen und Institutionen

  • Department of Pharmacy, Nippon Medical School Tama Nagayama Hospital, Tokyo, Japan.
  • Department of Emergency and Critical Care Medicine, Nippon Medical School Tama Nagayama Hospital, Tokyo, Japan.
  • Department of Emergency and Critical Care Medicine, Nippon Medical School Musashi Kosuigi Hospital, Kanagawa, Japan.

Zitieren

APA

Kondo, M., Yoshida, N., Yoshida, M., Tanaka, C., Tagami, T., Horikawa, K., Sugaya, K., & Takase, H. (2023). Physical compatibility of remimazolam with opioid analgesics, sedatives, and muscle relaxants during simulated Y-site administration. American Journal of Health-System Pharmacy. https://doi.org/10.1093/ajhp/zxac262

Vancouver

Kondo M, Yoshida N, Yoshida M, Tanaka C, Tagami T, Horikawa K, et al. Physical compatibility of remimazolam with opioid analgesics, sedatives, and muscle relaxants during simulated Y-site administration. American Journal of Health-System Pharmacy. 2023. doi:10.1093/ajhp/zxac262

BibTeX
@article{Kondo2023,
  author = {Kondo, Masayoshi and Yoshida, Naoki and Yoshida, Mariko and Tanaka, Chie and Tagami, Takashi and Horikawa, Kazumi and Sugaya, Kazutoshi and Takase, Hisamitsu},
  title = {Physical compatibility of remimazolam with opioid analgesics, sedatives, and muscle relaxants during simulated Y-site administration},
  journal = {American Journal of Health-System Pharmacy},
  year = {2023},
  doi = {10.1093/ajhp/zxac262}
}
Kostenlos starten →