EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Concordance between awake blood pressure on home and ambulatory blood pressure monitoring in older adults

Lama Ghazi iD, Emily B Levitan iD, Medha J Dubal, Rong Wei, Teresa N Harrison, Joseph E Schwartz iD, Paul Muntner, Daichi Shimbo iD, Kristi Reynolds iD

American Journal of Hypertension · 01.09.2026 · 39 (9) · 1083-1091

DOI: 10.1093/ajh/hpag045 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift American Journal of Hypertension, online erschienen am 10.05.2026. Verfasst von Lama Ghazi und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Epidemiology, The University of Alabama at Birmingham, Birmingham, AL, United States. Hauptthemen laut MEDLINE: Blood Pressure Monitoring, Ambulatory, Blood Pressure, Wakefulness, Hypertension. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIH HHS, NHLBI NIH HHS, National Heart, Lung and Blood Institute.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Determining the agreement between ambulatory blood pressure (BP) monitoring (ABPM) and home BP monitoring (HBPM) can inform their use.

Methods

Participants ≥65 years of age taking antihypertensive medication in the AMBROSIA-HOME study completed 24 hours of ABPM and 7 days of HBPM. Controlled office and awake BP was defined as mean systolic BP (SBP)/diastolic BP (DBP) <130/<80 mm Hg and uncontrolled office and awake BP as mean SBP or DBP ≥130/80 mm Hg. Masked uncontrolled hypertension was defined as controlled clinic BP with uncontrolled BP on HBPM or ABPM, and white coat effect as uncontrolled clinic BP with controlled BP on HBPM or ABPM.

Results

Among 510 participants (mean age: 74 years; 57% female), mean (SD) awake SBP/DBP was 135.6 (13.9)/73.7 (7.9) mm Hg on HBPM and 134.7 (13.9)/73.6 (8.5) mm Hg on ABPM. The mean difference (limits of agreement) between HBPM and ABPM for awake SBP and DBP was 0.84 (−20.6 to 22.3) mm Hg and 0.07 (−12.5 to 12.6) mm Hg, respectively. Intraclass correlation coefficients for mean awake SBP and DBP between HBPM and ABPM were 0.68 (95% CI: 0.63-0.73) and 0.69 (95% CI: 0.64-0.73), respectively. The Kappa statistics (95% CI) for uncontrolled BP, masked uncontrolled hypertension, and white coat effect were 0.47 (0.39-0.55), 0.43 (0.31-0.54), and 0.35 (0.21-0.49), respectively.

Conclusions

HBPM and ABPM yielded comparable mean awake BP values with a wide limit of agreement and fair to moderate agreement for identifying BP phenotypes in older adults taking antihypertensive treatment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood Pressure Monitoring, AmbulatoryBlood PressureWakefulnessHypertensionWhite Coat HypertensionMasked HypertensionHumansFemaleAgedMaleAntihypertensive AgentsPredictive Value of TestsAged, 80 and overAge FactorsReproducibility of Results

Stichwörter der Autor:innen

ABPMHBPMawake BPblood pressurehypertensionout-of-office BP measurement

Substanzen

Antihypertensive Agents

Autor:innen und Institutionen

  • Department of Epidemiology, The University of Alabama at Birmingham, Birmingham, AL, United States.
  • Department of Research and Evaluation, Kaiser Permanente Southern California, Pasadena, CA, United States.
  • Department of Medicine, Center for Behavioral and Cardiovascular Health, Columbia University Irving Medical Center, New York, NY, United States.
  • Department of Psychiatry and Behavioral Health, Stony Brook University Renaissance School of Medicine, Stony Brook, NY, United States.
  • Perisphere Real World Evidence, LLC, Austin, TX, United States.
  • Department of Medicine, Columbia University Irving Medical Center, New York, NY, United States.

ORCID-Profile: Lama Ghazi, Emily B Levitan, Joseph E Schwartz, Daichi Shimbo, Kristi Reynolds

Förderung

  • NIH HHS
  • NHLBI NIH HHS
  • National Heart, Lung and Blood Institute
  • National Institutes of Health

Zitieren

APA

Ghazi, L., Levitan, E. B., Dubal, M. J., Wei, R., Harrison, T. N., Schwartz, J. E., Muntner, P., Shimbo, D., & Reynolds, K. (2026). Concordance between awake blood pressure on home and ambulatory blood pressure monitoring in older adults. American Journal of Hypertension, 39(9), 1083-1091. https://doi.org/10.1093/ajh/hpag045

Vancouver

Ghazi L, Levitan EB, Dubal MJ, Wei R, Harrison TN, Schwartz JE, et al. Concordance between awake blood pressure on home and ambulatory blood pressure monitoring in older adults. American Journal of Hypertension. 2026;39(9):1083-1091. doi:10.1093/ajh/hpag045

BibTeX
@article{Ghazi2026,
  author = {Ghazi, Lama and Levitan, Emily B and Dubal, Medha J and Wei, Rong and Harrison, Teresa N and Schwartz, Joseph E and Muntner, Paul and Shimbo, Daichi and Reynolds, Kristi},
  title = {Concordance between awake blood pressure on home and ambulatory blood pressure monitoring in older adults},
  journal = {American Journal of Hypertension},
  year = {2026},
  volume = {39},
  number = {9},
  pages = {1083--1091},
  doi = {10.1093/ajh/hpag045}
}
Kostenlos starten →