EUVIMEDEUVIMED entdecken
Open Access

Technical Dissonance in Home Blood Pressure Monitoring After Stroke: Having the Machine, but Not Using Correctly

Rachel Forman iD, Catherine M Viscoli, Katherine Meurer, Kevin N Sheth, Lauren H Sansing, Adam de Havenon, Richa Sharma, Melissa Mariscal, Walter N Kernan

American Journal of Hypertension · 15.03.2023 · 36 (4) · 195-200

DOI: 10.1093/ajh/hpac129 ↗

Kurz gefasst

Fachartikel in der Zeitschrift American Journal of Hypertension, online erschienen am 15.12.2022. Verfasst von Rachel Forman und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurology, Yale School of Medicine, New Haven, Connecticut, USA. Hauptthemen laut MEDLINE: Blood Pressure Monitoring, Ambulatory, Hypertension. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NINDS NIH HHS, NCATS NIH HHS, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

In individuals with hypertension (HTN), lowering blood pressure (BP) after a stroke can lower the risk of stroke recurrence, but many patients do not reach the goal. Home blood pressure monitoring (HBPM) can help patients get to the goal, but rates of use and quality of technique have not been evaluated.

Methods

We conducted a cross-sectional study of patients with stroke. Patients were eligible if they had a stroke within 2 years, had HTN, and lived at home. We classified patients as correctly performing HBPM if they used an arm cuff, sat ≥ 1 min before measurement, took ≥ 2 measurements, and use within 6 months. The primary outcome was the proportion of patients who had an HBPM and used it correctly, which we calculated according to race and ethnicity. We also asked patients what they would do if they found results outside the goal.

Results

Among 150 participants, 120 (81%) possessed an HBPM and 29 (21%) used it correctly. We observed no significant disparity in rates of possession or correct use between non-Hispanic White participants and participants from underrepresented groups. Seventy percent of non-Hispanic White patients said they would contact their provider if their BP was above goal vs. 52% of underrepresented patients (P = 0.21).

Conclusions

Most patients after stroke have an HBPM, but only about 1 in 5 use it correctly. Approximately half of the patients from underrepresented racial or ethnic groups do not have a plan for responding to the values above goal. Our results indicate opportunities to improve the dissemination and correct use of HBPM.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood Pressure Monitoring, AmbulatoryHypertensionHumansCross-Sectional StudiesBlood PressureEthnicity

Stichwörter der Autor:innen

blood pressuredisparitieshome blood pressure monitoringhypertensionstroke

Autor:innen und Institutionen

  • Department of Neurology, Yale School of Medicine, New Haven, Connecticut, USA.
  • Department of Internal Medicine, Yale School of Medicine, New Haven, Connecticut, USA.

ORCID-Profile: Rachel Forman

Förderung

  • NINDS NIH HHS
  • NCATS NIH HHS
  • National Institutes of Health
  • National Institute of Neurological Disorders and Stroke

Zitieren

APA

Forman, R., Viscoli, C. M., Meurer, K., Sheth, K. N., Sansing, L. H., de Havenon, A., Sharma, R., Mariscal, M., & Kernan, W. N. (2023). Technical Dissonance in Home Blood Pressure Monitoring After Stroke: Having the Machine, but Not Using Correctly. American Journal of Hypertension, 36(4), 195-200. https://doi.org/10.1093/ajh/hpac129

Vancouver

Forman R, Viscoli CM, Meurer K, Sheth KN, Sansing LH, de Havenon A, et al. Technical Dissonance in Home Blood Pressure Monitoring After Stroke: Having the Machine, but Not Using Correctly. American Journal of Hypertension. 2023;36(4):195-200. doi:10.1093/ajh/hpac129

BibTeX
@article{Forman2023,
  author = {Forman, Rachel and Viscoli, Catherine M and Meurer, Katherine and Sheth, Kevin N and Sansing, Lauren H and de Havenon, Adam and Sharma, Richa and Mariscal, Melissa and Kernan, Walter N},
  title = {Technical Dissonance in Home Blood Pressure Monitoring After Stroke: Having the Machine, but Not Using Correctly},
  journal = {American Journal of Hypertension},
  year = {2023},
  volume = {36},
  number = {4},
  pages = {195--200},
  doi = {10.1093/ajh/hpac129}
}
Kostenlos starten →