Rapid clinical deployment of UBA1 testing in patients with VEXAS syndrome
American Journal of Clinical Pathology · 2025
DOI: 10.1093/ajcp/aqaf051 ↗Kurz gefasst
Fachartikel in der Zeitschrift American Journal of Clinical Pathology, 2025. Verfasst von Paul A Wadsworth und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pathology, Stanford University School of Medicine, Stanford, CA, United States. Hauptthemen laut MEDLINE: Ubiquitin-Activating Enzymes. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Objective
VEXAS (vacuoles, E1 enzyme, X-linked, autoinflammatory, somatic) is a recently described autoinflammatory syndrome caused by pathogenic variants in UBA1. However, there is a dearth of widely available UBA1 testing aside from large, expensive sequencing studies. Thus, we sought to rapidly develop, validate, and clinically deploy a cost-effective assay for detecting the most common UBA1 variants.
Methods
We developed, validated, and implemented a single base extension mass spectrometry assay for detecting pathogenic UBA1 variants at the c.121, c.122, and c.118-1 positions in patients with suspected VEXAS syndrome. Assay performance characteristics were assessed using peripheral blood and bone marrow samples from patients with (n = 8) and without (n = 36) VEXAS.
Results
The assay demonstrated a lower limit of detection (LOD) of 10% variant allele fraction for each mutation. The analytical accuracy, sensitivity, and specificity were each demonstrated to be 100% at the LOD, with excellent intra- and interrun reproducibility. Based on literature review of reported UBA1 variants associated with VEXAS, to date, this assay detects the most prevalent variants, with a clinical sensitivity of 97% or more.
Conclusions
A cost-effective, mass spectrometry–based assay with high analytical and clinical performance can feasibly be implemented in hospital laboratories for diagnosis of VEXAS syndrome.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Pathology, Stanford University School of Medicine, Stanford, CA, United States.
- Present affiliation: Department of Pathology and Laboratory Medicine, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, United States.
- Present affiliation: Guardant Health, Redwood City, CA, United States.
- Molecular Genetic Pathology Laboratory, Stanford Health Care, Stanford, CA, United States.
- Systemic Autoimmunity Branch, National Institute of Arthritis and Musculoskeletal and Skin Diseases, National Institutes of Health, Bethesda, MD, United States.
- Department of Medicine, Division of Immunology and Rheumatology, University of Maryland, Baltimore, MD, United States.
ORCID-Profile: Paul A Wadsworth, Chandler C Ho, Marcela A Ferrada, Carlos J Suarez
Zitieren
APA
Wadsworth, P. A., Chen, S. B., Lawrence, L., Ho, C. C., Le, J. E., Libiran, P., Grayson, P. C., Ferrada, M. A., Beck, D. B., & Suarez, C. J. (2025). Rapid clinical deployment of UBA1 testing in patients with VEXAS syndrome. American Journal of Clinical Pathology. https://doi.org/10.1093/ajcp/aqaf051
Vancouver
Wadsworth PA, Chen SB, Lawrence L, Ho CC, Le JE, Libiran P, et al. Rapid clinical deployment of UBA1 testing in patients with VEXAS syndrome. American Journal of Clinical Pathology. 2025. doi:10.1093/ajcp/aqaf051
BibTeX
@article{Wadsworth2025,
author = {Wadsworth, Paul A and Chen, Simon B and Lawrence, Lauren and Ho, Chandler C and Le, Joseph E and Libiran, Paolo and Grayson, Peter C and Ferrada, Marcela A and Beck, David B and Suarez, Carlos J},
title = {Rapid clinical deployment of UBA1 testing in patients with VEXAS syndrome},
journal = {American Journal of Clinical Pathology},
year = {2025},
doi = {10.1093/ajcp/aqaf051}
}
EUVIMED