Quality improvements are effective in reducing preanalytical errors and rejection rates in clinical laboratories
American Journal of Clinical Pathology · 2024
DOI: 10.1093/ajcp/aqae050 ↗Kurz gefasst
Leserbrief in der Zeitschrift American Journal of Clinical Pathology, 2024. Verfasst von Mohammed Suleiman und 2 weiteren Autor:innen. Beteiligte Einrichtung: Sidra Medicine, Doha, Qatar. Hauptthemen laut MEDLINE: Quality Improvement, Laboratories, Clinical. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 5 Literaturangaben.
Abstract (Originalsprache)
We read with great interest the article by Deress et al,1 in which data recorded in the laboratory logbooks over a 2-year period in a university tertiary-care hospital in Ethiopia were analyzed to establish trends in specimen rejection rates and causes of potential rejection. Rejection of samples can lead to direct clinical harm to the patient, such as unnecessary re-collection of samples, patient discomfort, and delays in diagnosis and treatment.2 We agree with the authors’ recommendation that implementing quality improvement measures is necessary to reduce the clinical harms caused by the unnecessary rejection of samples, and a comprehensive investigation is needed to uncover the underlying factors behind the high rejection rates in their hospital. We further suggest that the authors perform a root-cause analysis to investigate the cause of rejection in their institution; implement repeated, small, rapid cycle quality improvement projects; and introduce automated electronic methods, if possible, to reduce rejection rates. Rapid quality improvement projects are formed by multidisciplinary teams from all stakeholder groups (physicians, nurses, phlebotomists, laboratory technologists) in the institution; these teams work together to educate and train hospital staff involved in ordering and collecting samples from patients. If implemented correctly, these quality improvement projects are effective and showed a notable reduction in rejection rates in several previous studies. At the Heart Hospital in Qatar, rapid-cycle quality initiatives focusing on training and educating physicians and phlebotomists reduced the sample rejection rate from 1.43% to 0.47%.3 A strategy to standardize collection procedures and other preanalytical steps based on the Lean Six Sigma quality methodology in the Sarasota Memorial Health Care System in the United States dramatically reduced the rejection rate of samples due to hemolysis by 90%.4 Another important strategy to reduce the rejection rate is to use electronic health records and automated electronic identification systems to reduce human errors in ordering and patient identification, which accounted for almost 50% of the rejections Deress at al reported.1 Using electronic systems such as electronic scanners to confirm patient identification before collecting samples has been shown to reduce preanalytical errors, especially labeling errors, 5-fold in 1 study.5 The studies briefly discussed earlier are excellent examples of the tools clinical laboratories can use to reduce rejection rates and the clinical harm resulting from re-collection of samples, ultimately improving patient care.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Sidra Medicine, Doha, Qatar.
- Sidra Medicine and Weill Cornell Medicine-Qatar, Doha, Qatar.
ORCID-Profile: Mohammed Suleiman
Zitieren
APA
Suleiman, M., Pérez-López, A., & Tang, P. (2024). Quality improvements are effective in reducing preanalytical errors and rejection rates in clinical laboratories. American Journal of Clinical Pathology. https://doi.org/10.1093/ajcp/aqae050
Vancouver
Suleiman M, Pérez-López A, Tang P. Quality improvements are effective in reducing preanalytical errors and rejection rates in clinical laboratories. American Journal of Clinical Pathology. 2024. doi:10.1093/ajcp/aqae050
BibTeX
@article{Suleiman2024,
author = {Suleiman, Mohammed and Pérez-López, Andrés and Tang, Patrick},
title = {Quality improvements are effective in reducing preanalytical errors and rejection rates in clinical laboratories},
journal = {American Journal of Clinical Pathology},
year = {2024},
doi = {10.1093/ajcp/aqae050}
}
EUVIMED