SEMTWIST Quantification of Biofilm Infection in Human Chronic Wound Using Scanning Electron Microscopy and Machine Learning
Advances in Wound Care · 2025
DOI: 10.1089/wound.2024.0291 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advances in Wound Care, 2025. Verfasst von Surabhi Singh und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, Pennsylvania, USA. Hauptthemen laut MEDLINE: Biofilms, Microscopy, Electron, Scanning, Machine Learning, Wound Infection. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 81 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NHLBI NIH HHS, NIGMS NIH HHS, NIDDK NIH HHS.
Abstract (Originalsprache)
Objective
To develop scanning electron microscopy-based Trainable Weka (Waikato Environment for Knowledge Analysis) Intelligent Segmentation Technology (SEMTWIST), an open-source software tool, for structural detection and rigorous quantification of wound biofilm aggregates in complex human wound tissue matrix. Approach: SEMTWIST model was standardized to quantify biofilm infection (BFI) abundance in 240 distinct SEM images from 60 human chronic wound-edge biospecimens (four technical replicates of each specimen). Results from SEMTWIST were compared against human expert assessments and the gold standard for molecular BFI detection, that is, peptide nucleic acid fluorescence in situ hybridization (PNA-FISH).
Results
Correlation and Bland-Altman plot demonstrated a robust correlation (r = 0.82, p < 0.01), with a mean bias of 1.25, and 95% limit of agreement ranging from -43.40 to 47.11, between SEMTWIST result and the average scores assigned by trained human experts. While interexpert variability highlighted potential bias in manual assessments, SEMTWIST provided consistent results. Bacterial culture detected infection but not biofilm aggregates. Whereas the wheat germ agglutinin staining exhibited nonspecific staining of host tissue components and failed to provide a specific identification of BFI. The molecular identification of biofilm aggregates using PNA-FISH was comparable with SEMTWIST, highlighting the robustness of the developed approach. Innovation: This study introduces a novel approach "SEMTWIST" for in-depth analysis and precise differentiation of biofilm aggregates from host tissue elements, enabling accurate quantification of BFI in chronic wound SEM images.
Conclusion
Open-source SEMTWIST offers a reliable and robust framework for standardized quantification of BFI burden in human chronic wound-edge tissues, supporting clinical diagnosis and guiding treatment.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Surgery, McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, Pennsylvania, USA.
ORCID-Profile: Chandan K Sen, Sashwati Roy
Förderung
- NHLBI NIH HHS
- NIGMS NIH HHS
- NIDDK NIH HHS
Zitieren
APA
Singh, S., Muniz De Oliveira, F., Wang, C., Kumar, M., Xuan, Y., DeMazumder, D., Sen, C. K., & Roy, S. (2025). SEMTWIST Quantification of Biofilm Infection in Human Chronic Wound Using Scanning Electron Microscopy and Machine Learning. Advances in Wound Care. https://doi.org/10.1089/wound.2024.0291
Vancouver
Singh S, Muniz De Oliveira F, Wang C, Kumar M, Xuan Y, DeMazumder D, et al. SEMTWIST Quantification of Biofilm Infection in Human Chronic Wound Using Scanning Electron Microscopy and Machine Learning. Advances in Wound Care. 2025. doi:10.1089/wound.2024.0291
BibTeX
@article{Singh2025,
author = {Singh, Surabhi and Muniz De Oliveira, Fabio and Wang, Cong and Kumar, Manoj and Xuan, Yi and DeMazumder, Deeptankar and Sen, Chandan K and Roy, Sashwati},
title = {SEMTWIST Quantification of Biofilm Infection in Human Chronic Wound Using Scanning Electron Microscopy and Machine Learning},
journal = {Advances in Wound Care},
year = {2025},
doi = {10.1089/wound.2024.0291}
}
EUVIMED