Explainable Image Quality Assessments in Teledermatological Photography
Telemedicine and e-Health · 2023-09 · 29 (9) · 1342-1348
DOI: 10.1089/tmj.2022.0405 ↗Kurz gefasst
Fachartikel in der Zeitschrift Telemedicine and e-Health, online erschienen am 29.08.2023. Verfasst von Raluca Jalaboi und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Applied Mathematics and Computer Science, Technical University of Denmark, Lyngby, Denmark. Hauptthemen laut MEDLINE: Skin Neoplasms, Remote Consultation, Mobile Applications. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background and Objectives : Image quality is a crucial factor in the effectiveness and efficiency of teledermatological consultations. However, up to 50% of images sent by patients have quality issues, thus increasing the time to diagnosis and treatment. An automated, easily deployable, explainable method for assessing image quality is necessary to improve the current teledermatological consultation flow. We introduce ImageQX, a convolutional neural network for image quality assessment with a learning mechanism for identifying the most common poor image quality explanations: bad framing, bad lighting, blur, low resolution, and distance issues.
Methods
ImageQX was trained on 26,635 photographs and validated on 9,874 photographs, each annotated with image quality labels and poor image quality explanations by up to 12 board-certified dermatologists. The photographic images were taken between 2017 and 2019 using a mobile skin disease tracking application accessible worldwide.
Results
Our method achieves expert-level performance for both image quality assessment and poor image quality explanation. For image quality assessment, ImageQX obtains a macro F1-score of 0.73 ± 0.01, which places it within standard deviation of the pairwise inter-rater F1-score of 0.77 ± 0.07. For poor image quality explanations, our method obtains F1-scores of between 0.37 ± 0.01 and 0.70 ± 0.01, similar to the inter-rater pairwise F1-score of between 0.24 ± 0.15 and 0.83 ± 0.06. Moreover, with a size of only 15 MB, ImageQX is easily deployable on mobile devices.
Conclusion
With an image quality detection performance similar to that of dermatologists, incorporating ImageQX into the teledermatology flow can enable a better, faster flow for remote consultations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Applied Mathematics and Computer Science, Technical University of Denmark, Lyngby, Denmark.
- Medable A/S, Copenhagen, Denmark.
- Pioneer Centre for AI, Copenhagen, Denmark.
- Bioinformatics Centre, Department of Biology, University of Copenhagen, Copenhagen, Denmark.
- Center for Genomic Medicine, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark.
ORCID-Profile: Raluca Jalaboi
Zitieren
APA
Jalaboi, R., Winther, O., & Galimzianova, A. (2023). Explainable Image Quality Assessments in Teledermatological Photography. Telemedicine and e-Health, 29(9), 1342-1348. https://doi.org/10.1089/tmj.2022.0405
Vancouver
Jalaboi R, Winther O, Galimzianova A. Explainable Image Quality Assessments in Teledermatological Photography. Telemedicine and e-Health. 2023;29(9):1342-1348. doi:10.1089/tmj.2022.0405
BibTeX
@article{Jalaboi2023,
author = {Jalaboi, Raluca and Winther, Ole and Galimzianova, Alfiia},
title = {Explainable Image Quality Assessments in Teledermatological Photography},
journal = {Telemedicine and e-Health},
year = {2023},
volume = {29},
number = {9},
pages = {1342--1348},
doi = {10.1089/tmj.2022.0405}
}