Scoping Review in der Zeitschrift Telemedicine and e-Health, online erschienen am 01.06.2023. Verfasst von Sheida Knight und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Computer Science, University of Saskatchewan, Saskatoon, Saskatchewan, Canada. Hauptthemen laut MEDLINE: COVID-19, Telemedicine, Wearable Electronic Devices. Die Arbeit wurde bisher 34-mal zitiert (Crossref) und nennt 52 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Objectives: Photoplethysmography (PPG) sensors have been increasingly used for remote patient monitoring, especially during the COVID-19 pandemic, for the management of chronic diseases and neurological disorders. There is an urgent need to evaluate the accuracy of these devices. This scoping review considers the latest applications of wearable PPG sensors with a focus on studies that used wearable PPG sensors to monitor various health parameters. The primary objective is to report the accuracy of the PPG sensors in both real-world and clinical settings.

Methods

This scoping review was conducted in accordance with Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA). Studies were identified by querying the Medline, Embase, IEEE, and CINAHL databases. The goal was to capture eligible studies that used PPG sensors to monitor various health parameters for populations with a minimum of 30 participants, with at least some of the population having relevant health issues. A total of 2,996 articles were screened and 28 are included in this review.

Results

The health parameters and disorders identified and investigated in this study include heart rate and heart rate variability, atrial fibrillation, blood pressure (BP), obstructive sleep apnea, blood glucose, heart failure, and respiratory rate. An overview of the algorithms used, and their limitations is provided.

Conclusion

Some of the barriers identified in evaluating the accuracy of multiple types of wearable devices include the absence of reporting standard accuracy metrics and a general paucity of studies with large subject size in real-world settings, especially for parameters such as BP.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

COVID-19TelemedicineWearable Electronic DevicesHumansHeart RatePandemicsPhotoplethysmography

Stichwörter der Autor:innen

COVIDpulse oximetrytelehealthwearable deviceswearable sensors

Autor:innen und Institutionen

  • Department of Computer Science, University of Saskatchewan, Saskatoon, Saskatchewan, Canada.
  • Center for Bio-Integrated Electronics at Northwestern University, Evanston, Illinois, USA.
  • Guilan University of Medical Sciences, Rasht, Guilan, Iran.
  • Graduate Institute of Biomedical Informatics, Taipei Medical University, Taipei, Taiwan.

Zitieren

APA

Knight, S., Lipoth, J., Namvari, M., Gu, C., Hedayati, M., Syed-Abdul, S., & Spiteri, R. J. (2023). The Accuracy of Wearable Photoplethysmography Sensors for Telehealth Monitoring: A Scoping Review. Telemedicine and e-Health, 29(6), 813-828. https://doi.org/10.1089/tmj.2022.0182

Vancouver

Knight S, Lipoth J, Namvari M, Gu C, Hedayati M, Syed-Abdul S, et al. The Accuracy of Wearable Photoplethysmography Sensors for Telehealth Monitoring: A Scoping Review. Telemedicine and e-Health. 2023;29(6):813-828. doi:10.1089/tmj.2022.0182

BibTeX
@article{Knight2023,
  author = {Knight, Sheida and Lipoth, Jessica and Namvari, Mina and Gu, Carol and Hedayati, Mojtaba and Syed-Abdul, Shabbir and Spiteri, Raymond J},
  title = {The Accuracy of Wearable Photoplethysmography Sensors for Telehealth Monitoring: A Scoping Review},
  journal = {Telemedicine and e-Health},
  year = {2023},
  volume = {29},
  number = {6},
  pages = {813--828},
  doi = {10.1089/tmj.2022.0182}
}
Kostenlos starten →