EUVIMEDEUVIMED entdecken
Multizentrische Studie

Optimizing Diagnostic Accuracy of Fine Needle Aspiration Biopsy Calcitonin Measurements in Detecting Medullary Thyroid Carcinoma

Andrea Camila Cavallo iD, Fabián Pitoia iD, Javier Roberti, Pablo Brenzoni, Melisa Lencioni, Maria Jose Jaroslavsky, Eunice Spengler, Ana Voogd, Claudia Firpo, Pedro Saco, Federico Piñero, Maria Negueruela

Thyroid® · 2024

DOI: 10.1089/thy.2023.0313 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Thyroid®, 2024. Verfasst von Andrea Camila Cavallo und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Endocrinology, Hospital Universitario Austral, Buenos Aires, Argentina. Hauptthemen laut MEDLINE: Thyroid Nodule, Thyroid Neoplasms, Carcinoma, Neuroendocrine, Goiter. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 47 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The optimal cutoff value of calcitonin (Ctn) levels measured using an electrochemiluminescence immunoassay (ECLIA) obtained from the washout fluid of fine needle aspiration (FNA-Ctn) for the diagnosis of medullary thyroid carcinoma (MTC) is currently not established. We evaluated the diagnostic accuracy and clinical utility of FNA-Ctn for the diagnosis and location of MTC in patients with nodular or multinodular goiters.

Methods

This was a case–control study nested on a prospective multicenter cohort of patients with nodular or multinodular goiter, normal or elevated serum Ctn, and thyroidectomy indications. Ctn and FNA-Ctn were measured using ECLIA methodology before surgery. From this nested cohort, MTC cases and controls (non-medullary pathology) were identified from the final pathological analysis. Cumulative incidence sampling of controls was randomly performed at a ratio of 1:2. Sensitivity, specificity, and area under the receiver operator curve (AUROC) were calculated for patients and the total number of thyroid nodules.

Results

From 1272 patients included in the prospective cohort, 50 MTC cases and 105 controls were included. In this study, 286 thyroid nodules were evaluated (63 MTC and 223 non-MTCs). The median serum Ctn value was significantly higher in cases (525 pg/mL [interquartile range (IQR), 162.5–1.200]) than in controls (1.6 pg/mL [IQR, 0.5–5.6]; p < 0.001). The median FNA-Ctn value was significantly higher in MTC nodules (3.100 pg/mL [IQR, 450–45,200]) than in non-MTC nodules (0.5 pg/mL [IQR, 0.5–0.5]; p < 0.0001). In 11 MTC patients with multinodular goiter, the FNA-Ctn value was significantly higher in non-medullary nodules located in the same lobe where an MTC nodule was diagnosed ( p = 0.0002). Overall, the FNA-Ctn AUROC was 0.99 [95% confidence interval, 0.98–1.0], and a threshold of ≥220 pg/mL showed 100% sensitivity and 98% specificity for MTC diagnosis.

Conclusions

The use of FNA-Ctn measured by ECLIA showed adequate diagnostic accuracy for MTC diagnosis. Moreover, it may be clinically useful for localization in multinodular goiter when lobectomy is considered. Clinical Trial Registration: Clinicaltrials.gov NCT06067594.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Thyroid NoduleThyroid NeoplasmsCarcinoma, NeuroendocrineGoiterHumansBiopsy, Fine-NeedleCalcitoninCase-Control StudiesProspective Studies

Stichwörter der Autor:innen

calcitonincalcitonin in washout fluid of fine needle aspirationmedullary thyroid carcinoma

Substanzen

Calcitonin

Autor:innen und Institutionen

  • Department of Endocrinology, Hospital Universitario Austral, Buenos Aires, Argentina.
  • Department of Endocrinology, Sanatorio Las Lomas, Buenos Aires, Argentina.
  • Department of Endocrinology and Hospital Alta Complejidad, Formosa, Argentina.
  • Division of Endocrinology, Hospital de Clínicas, University of Buenos Aires, Buenos Aires, Argentina.
  • Centre for Research in Epidemiology and Public Health (CIESP) - National Scientific and Technical Research Council (CONICET), Buenos Aires, Argentina.
  • Department of Endocrinological Biochemistry Service, Hospital Universitario Austral, Buenos Aires, Argentina.

ORCID-Profile: Andrea Camila Cavallo, Fabián Pitoia

Zitieren

APA

Cavallo, A. C., Pitoia, F., Roberti, J., Brenzoni, P., Lencioni, M., Jaroslavsky, M. J., Spengler, E., Voogd, A., Firpo, C., Saco, P., Piñero, F., & Negueruela, M. (2024). Optimizing Diagnostic Accuracy of Fine Needle Aspiration Biopsy Calcitonin Measurements in Detecting Medullary Thyroid Carcinoma. Thyroid®. https://doi.org/10.1089/thy.2023.0313

Vancouver

Cavallo AC, Pitoia F, Roberti J, Brenzoni P, Lencioni M, Jaroslavsky MJ, et al. Optimizing Diagnostic Accuracy of Fine Needle Aspiration Biopsy Calcitonin Measurements in Detecting Medullary Thyroid Carcinoma. Thyroid®. 2024. doi:10.1089/thy.2023.0313

BibTeX
@article{Cavallo2024,
  author = {Cavallo, Andrea Camila and Pitoia, Fabián and Roberti, Javier and Brenzoni, Pablo and Lencioni, Melisa and Jaroslavsky, Maria Jose and Spengler, Eunice and Voogd, Ana and Firpo, Claudia and Saco, Pedro and Piñero, Federico and Negueruela, Maria},
  title = {Optimizing Diagnostic Accuracy of Fine Needle Aspiration Biopsy Calcitonin Measurements in Detecting Medullary Thyroid Carcinoma},
  journal = {Thyroid®},
  year = {2024},
  doi = {10.1089/thy.2023.0313}
}
Kostenlos starten →