Robust, Automated Analysis of Electrophysiology in Induced Pluripotent Stem Cell-Derived Micro-Heart Muscle for Drug Toxicity
Tissue Engineering Part C: Methods · 01.09.2022 · 28 (9) · 457-468
DOI: 10.1089/ten.tec.2022.0053 ↗Kurz gefasst
Fachartikel in der Zeitschrift Tissue Engineering Part C: Methods, online erschienen am 13.09.2022. Verfasst von Kasoorelope Oguntuyo und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, Missouri, USA. Hauptthemen laut MEDLINE: Antimalarials, Drug-Related Side Effects and Adverse Reactions, Induced Pluripotent Stem Cells. Die Arbeit wurde bisher 28-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NHLBI NIH HHS, NIGMS NIH HHS.
Abstract (Originalsprache)
Drugs are often removed from clinical trials or market progression owing to their unforeseen effects on cardiac action potential and calcium handling. Induced pluripotent stem cell-derived cardiomyocytes and tissues fabricated from these cells are promising as screening tools for early identification of these potential cardiac liabilities. In this study, we describe an automated, open-source MATLAB-based analysis software for calculating cardiac action potentials and calcium transients from fluorescent reporters. We first identified the most robust manner in which to automatically identify the initiation point for action potentials and calcium transients in a user-independent manner, and used this approach to quantify the duration and morphology of these signals. We then demonstrate the software by assessing changes to action potentials and calcium transients in our micro-heart muscles after exposure to hydroxychloroquine, an antimalarial drug with known cardiac liability. Consistent with clinical observations, our system predicted mild action potential prolongation. However, we also observed marked calcium transient suppression, highlighting the advantage of testing multiple physiologic readouts in cardiomyocytes rather than relying on heterologous overexpression of single channels such as the human ether-a-go-go -related gene channel. This open-source software can serve as a useful, high-throughput tool for analyzing cardiomyocyte physiology from fluorescence imaging.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, Missouri, USA.
- Department of Mechanical Engineering and Materials Science, Washington University in St. Louis, St. Louis, Missouri, USA.
- Division of Cardiology, Department of Medicine, Washington University in St. Louis, St. Louis, Missouri, USA.
- Department of Chemistry, University of California, Berkeley, Berkeley, California, USA.
ORCID-Profile: Kasoorelope Oguntuyo, Jingxuan Guo, Druv Bhagavan, Po Wei Kang, Evan Miller, Jonathan R Silva, Nathaniel Huebsch
Förderung
- NHLBI NIH HHS
- NIGMS NIH HHS
Zitieren
APA
Oguntuyo, K., Schuftan, D., Guo, J., Simmons, D., Bhagavan, D., Moreno, J. D., Kang, P. W., Miller, E., Silva, J. R., & Huebsch, N. (2022). Robust, Automated Analysis of Electrophysiology in Induced Pluripotent Stem Cell-Derived Micro-Heart Muscle for Drug Toxicity. Tissue Engineering Part C: Methods, 28(9), 457-468. https://doi.org/10.1089/ten.tec.2022.0053
Vancouver
Oguntuyo K, Schuftan D, Guo J, Simmons D, Bhagavan D, Moreno JD, et al. Robust, Automated Analysis of Electrophysiology in Induced Pluripotent Stem Cell-Derived Micro-Heart Muscle for Drug Toxicity. Tissue Engineering Part C: Methods. 2022;28(9):457-468. doi:10.1089/ten.tec.2022.0053
BibTeX
@article{Oguntuyo2022,
author = {Oguntuyo, Kasoorelope and Schuftan, David and Guo, Jingxuan and Simmons, Daniel and Bhagavan, Druv and Moreno, Jonathan D and Kang, Po Wei and Miller, Evan and Silva, Jonathan R and Huebsch, Nathaniel},
title = {Robust, Automated Analysis of Electrophysiology in Induced Pluripotent Stem Cell-Derived Micro-Heart Muscle for Drug Toxicity},
journal = {Tissue Engineering Part C: Methods},
year = {2022},
volume = {28},
number = {9},
pages = {457--468},
doi = {10.1089/ten.tec.2022.0053}
}
EUVIMED