Exo-Glove Shell: A Hybrid Rigid-Soft Wearable Robot for Thumb Opposition with an Under-Actuated Tendon-Driven System

Byungchul Kim iD, Hyungmin Choi, Kyubum Kim iD, Sejin Jeong, Kyu-Jin Cho

Soft Robotics · 2025

DOI: 10.1089/soro.2023.0089 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Soft Robotics, 2025. Verfasst von Byungchul Kim und 4 weiteren Autor:innen. Beteiligte Einrichtung: Biorobotics Laboratory, Department of Mechanical Engineering/Soft Robotics Research Center (SRRC)/Institute of Advanced Machines and Design (IAMD)/In…. Hauptthemen laut MEDLINE: Robotics, Thumb, Wearable Electronic Devices, Tendons. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 48 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Usability and functionality are important when designing hand-wearable robots; however, satisfying both indicators remains a challenging issue, even though researchers have made important progress with state-of-the-art robot components. Although hand-wearable robots require sufficient actuators and sensors considering their functionality, these components complicate the robot. Further, robot compliance should be carefully considered because it affects both indicators. For example, a robot’s softness makes it compact (improving usability) but also induces inaccurate force transmission (impacting functionality). To address this issue, we present in this paper a tendon-driven, hybrid, hand-wearable robot, named Exo-Glove Shell. The proposed robot assists in three primitive motions (i.e., thumb opposition motion, which is known as one of the most important hand functions, and flexion/extension of the index/middle fingers) while employing only four actuators by using an under-actuation mechanism. The Exo-Glove Shell was designed by combining a soft robotic body with rigid tendon router modules. The use of soft garments enables the robot to be fitted well to users without customization or adjustment of the mechanisms; the metal routers facilitate accurate force transmission. User tests conducted with an individual with a spinal cord injury (SCI) found that the robot could sufficiently and reliably assist in three primitive motions through its four actuators. The research also determined that the robot can assist in various postures with sufficient stability. Based on the grasp stability index proposed in this paper, user stability—when assisted by the proposed robot—was found to be 4.75 times that of an SCI person who did not use the Exo-Glove Shell.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RoboticsThumbWearable Electronic DevicesTendonsHumansEquipment Design

Stichwörter der Autor:innen

hybrid soft-rigid wearable robotsoft tendon-driven wearable robotunder-actuated mechanism

Autor:innen und Institutionen

  • Biorobotics Laboratory, Department of Mechanical Engineering/Soft Robotics Research Center (SRRC)/Institute of Advanced Machines and Design (IAMD)/Institute of Engineering Research, Seoul National University, Seoul, Kor…
  • Distributed Robotics Laboratory, Computer Science and Artificial Intelligence Laboratory (CSAIL), Massachusetts Institute of Technology, Cambridge, Massachusetts, USA.
  • Institute of Art, Department of Design and Craft, Seoul National University, Seoul, Korea.

ORCID-Profile: Byungchul Kim, Kyubum Kim

Zitieren

APA

Kim, B., Choi, H., Kim, K., Jeong, S., & Cho, K. J. (2025). Exo-Glove Shell: A Hybrid Rigid-Soft Wearable Robot for Thumb Opposition with an Under-Actuated Tendon-Driven System. Soft Robotics. https://doi.org/10.1089/soro.2023.0089

Vancouver

Kim B, Choi H, Kim K, Jeong S, Cho KJ. Exo-Glove Shell: A Hybrid Rigid-Soft Wearable Robot for Thumb Opposition with an Under-Actuated Tendon-Driven System. Soft Robotics. 2025. doi:10.1089/soro.2023.0089

BibTeX
@article{Kim2025,
  author = {Kim, Byungchul and Choi, Hyungmin and Kim, Kyubum and Jeong, Sejin and Cho, Kyu-Jin},
  title = {Exo-Glove Shell: A Hybrid Rigid-Soft Wearable Robot for Thumb Opposition with an Under-Actuated Tendon-Driven System},
  journal = {Soft Robotics},
  year = {2025},
  doi = {10.1089/soro.2023.0089}
}
Kostenlos starten →