Magnetic Continuum Robot with Intraoperative Magnetic Moment Programming

Yanfei Cao iD, Zhengxin Yang, Bo Hao, Xin Wang, Mingxue Cai, Zhaoyang Qi, Bonan Sun iD, Qinglong Wang, Li Zhang

Soft Robotics · 01.12.2023 · 10 (6) · 1209-1223

DOI: 10.1089/soro.2022.0202 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Soft Robotics, online erschienen am 04.12.2023. Verfasst von Yanfei Cao und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical and Automation Engineering, The Chinese University of Hong Kong, Hong Kong, China. Die Arbeit wurde bisher 37-mal zitiert (Crossref) und nennt 49 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Magnetic continuum robots (MCRs), which are free of complicated structural designs for transmission, can be miniaturized and are therefore widely used in the medical field. However, the deformation shapes of different segments, including deflection directions and curvatures, are difficult to control simultaneously under an external programmable magnetic field. This is because the latest MCRs have designs with an invariable magnetic moment combination or profile of one or more actuating units. Therefore, the limited dexterity of the deformation shape causes the existing MCRs to collide readily with their surroundings or makes them unable to approach difficult-to-reach regions. These prolonged collisions are unnecessary or even hazardous, especially for catheters or similar medical devices. In this study, a novel magnetic moment intraoperatively programmable continuum robot (MMPCR) is introduced. By applying the proposed magnetic moment programming method, the MMPCR can deform under three modalities, that is, J, C, and S shapes. Additionally, the deflection directions and curvatures of different segments in the MMPCR can be modulated as desired. Furthermore, the magnetic moment programming and MMPCR kinematics are modeled, numerically simulated, and experimentally validated. The experimental results exhibit a mean deflection angle error of 3.3° and correspond well with simulation results. Comparisons between navigation capacities of the MMPCR and MCR demonstrate that the MMPCR has a higher capacity for dexterous deformation.

Schlagwörter

Stichwörter der Autor:innen

continuum robotmagnetic actuationmagnetic moment programmingsoft robot

Autor:innen und Institutionen

  • Department of Mechanical and Automation Engineering, The Chinese University of Hong Kong, Hong Kong, China.
  • Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China.
  • Chow Yuk Ho Technology Center for Innovative Medicine, The Chinese University of Hong Kong, Hong Kong, China.
  • CUHK T Stone Robotics Institute, The Chinese University of Hong Kong, Hong Kong, China.
  • Department of Surgery, The Chinese University of Hong Kong, Hong Kong, China.

ORCID-Profile: Yanfei Cao, Bonan Sun

Zitieren

APA

Cao, Y., Yang, Z., Hao, B., Wang, X., Cai, M., Qi, Z., Sun, B., Wang, Q., & Zhang, L. (2023). Magnetic Continuum Robot with Intraoperative Magnetic Moment Programming. Soft Robotics, 10(6), 1209-1223. https://doi.org/10.1089/soro.2022.0202

Vancouver

Cao Y, Yang Z, Hao B, Wang X, Cai M, Qi Z, et al. Magnetic Continuum Robot with Intraoperative Magnetic Moment Programming. Soft Robotics. 2023;10(6):1209-1223. doi:10.1089/soro.2022.0202

BibTeX
@article{Cao2023,
  author = {Cao, Yanfei and Yang, Zhengxin and Hao, Bo and Wang, Xin and Cai, Mingxue and Qi, Zhaoyang and Sun, Bonan and Wang, Qinglong and Zhang, Li},
  title = {Magnetic Continuum Robot with Intraoperative Magnetic Moment Programming},
  journal = {Soft Robotics},
  year = {2023},
  volume = {10},
  number = {6},
  pages = {1209--1223},
  doi = {10.1089/soro.2022.0202}
}
Kostenlos starten →