Performance Comparison of Oximetry Devices During 6-Minute Walk Tests
Respiratory Care · 2025
DOI: 10.1089/respcare.12259 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Respiratory Care, 2025. Verfasst von Emma M Marshall und 8 weiteren Autor:innen. Beteiligte Einrichtung: Ms. Marshall, Dr. Dowman, Mr. Churchward, and Dr. Khor are affiliated with Institute of Breathing and Sleep, Victoria, Australia. Hauptthemen laut MEDLINE: Oximetry, Walk Test. Die Arbeit nennt 30 Literaturangaben.
Abstract (Originalsprache)
Background
Pulse oximetry is a common technique used to measure SpO2, with increasing numbers of portable devices of different designs and technical specifications. This study examined accuracy of commercial and medical-grade portable oximetry devices (BioBeat wristwatch, Nonin WristOx2 3150, and Heart Sure A320) in measuring SpO2 compared with the reference standard (Masimo Rad-5) during 6-min walk tests (6MWTs).
Methods
This prospective study included 50 subjects, with 10 recruited for each of the five target groups, including COPD, interstitial lung disease, pulmonary hypertension, oxygen therapy users, and other cardiac/respiratory diseases. All subjects underwent 6MWT using the reference standard and the three test oximetry devices. Accuracy was measured by comparing mean nadir SpO2. Subjects were asked to rate their preference for different oximetry devices at test completion.
Results
In contrast to the Masimo, the Nonin had lower nadir and mean SpO2 (P ≤ .001 for both), with higher measurements for the BioBeat (P < .001 for both) and no differences for the Heart Sure (P = .18 for nadir SpO2, P = .96 for mean SpO2). Time spent at SpO2 ≤ 88 was higher for the Nonin (70%, P < .001) but lower for the Heart Sure (58%, P < .001), compared with the Masimo (64%). There were no significant differences observed in peak heart rate measurements between the Masimo with the Nonin and BioBeat (P < .05 for both), with lower measurements using the Heart Sure (P < .001). The BioBeat was most preferable amongst subjects (n = 31), with all test oximeters having high patient satisfaction (mean \7-point Likert scale scores of 6-7).
Conclusion
The Heart Sure A320 and Nonin Wrist-Ox2 3150 had comparable performance in detecting nadir SpO2 within a mean difference of 3% in comparison with the Masimo Rad-5, with potential use for remote monitoring.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Ms. Marshall, Dr. Dowman, Mr. Churchward, and Dr. Khor are affiliated with Institute of Breathing and Sleep, Victoria, Australia.
- Ms. Marshall, Mr. Schulte, Ms. Logie, Mr. Churchward, and Dr. Khor are affiliated with Department of Respiratory and Sleep Medicine, Austin Health, Victoria, Australia.
- Ms. Filiex, Drs. Dowman, and Khor are affiliated with Respiratory Research@Alfred, Monash University, Victoria, Australia.
- Dr. Gin, Dr. Horrigan are affiliated with Department of Cardiology, Austin Health, Melbourne, Victoria, Australia.
- Dr. Dowman is affiliated with Department of Physiotherapy, Austin Health, Melbourne, Australia.
- Dr. Khor us affiliated with Department of Medicine, University of Melbourne, Victoria, Australia.
Zitieren
APA
Marshall, E. M., Filiex, A., Schulte, M., Logie, K. M., Gin, J., Horrigan, M., Dowman, L., Churchward, T. J., & Khor, Y. H. (2025). Performance Comparison of Oximetry Devices During 6-Minute Walk Tests. Respiratory Care. https://doi.org/10.1089/respcare.12259
Vancouver
Marshall EM, Filiex A, Schulte M, Logie KM, Gin J, Horrigan M, et al. Performance Comparison of Oximetry Devices During 6-Minute Walk Tests. Respiratory Care. 2025. doi:10.1089/respcare.12259
BibTeX
@article{Marshall2025,
author = {Marshall, Emma M and Filiex, Angeline and Schulte, Max and Logie, Karla M and Gin, Julian and Horrigan, Mark and Dowman, Leona and Churchward, Thomas J and Khor, Yet H},
title = {Performance Comparison of Oximetry Devices During 6-Minute Walk Tests},
journal = {Respiratory Care},
year = {2025},
doi = {10.1089/respcare.12259}
}
EUVIMED