Effect of Higher or Lower PEEP on Pendelluft During Spontaneous Breathing Efforts in Acute Hypoxemic Respiratory Failure
Respiratory Care · 2025-02 · 70 (2) · 126-133
DOI: 10.1089/respcare.12193 ↗Kurz gefasst
Klinische Studie (Phase I) in der Zeitschrift Respiratory Care, online erschienen am 03.02.2025. Verfasst von Thiago Bassi und 10 weiteren Autor:innen. Beteiligte Einrichtung: Drs Bassi, Slutsky, and Brochard are affiliated with Interdepartmental Division of Critical Care Medicine, University of Toronto, Toronto, Ontario, C…. Hauptthemen laut MEDLINE: Hypoxia, Positive-Pressure Respiration, Respiratory Insufficiency. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 23 Literaturangaben.
Abstract (Originalsprache)
Background
In acute hypoxemic respiratory failure (AHRF), spontaneous breathing effort can generate excessive regional lung stress and strain manifesting as pendelluft. Higher PEEP may reduce pendelluft and reduce regional lung stress and strain during spontaneous breathing. This study aimed to establish whether higher or lower PEEP ameliorates pendelluft and to characterize factors determining the presence and magnitude of pendelluft during spontaneous breathing efforts.
Methods
This study was a randomized crossover trial of higher versus lower PEEP applied after systematically initiating spontaneous breathing in subjects with moderate or severe AHRF. The presence and volume of pendelluft were assessed by electrical impedance tomography (EIT).
Results
EIT recordings were available for 20 of 30 subjects enrolled in the trial. After initiating spontaneous breathing, 11/20 exhibited pendelluft (proportion 55% [95% CI 32–76]). Following PEEP titration, the prevalence of pendelluft was not different between higher versus lower PEEP levels (50% vs 50%, P = .55). When present, pendelluft volume was generally small (median 28 [interquartile range 8–93] mL) but ranged as high as 364 mL. Pendelluft was associated with higher respiratory effort (esophageal pressure [P es ] swing [ΔP es ] median −15 cm H 2 O vs ΔP es median −8 cm H 2 O, P = .01), higher pulmonary flow resistance (median 8 cm H 2 O/L/s vs median 3 cm H 2 O/L/s, P < .001), and higher dynamic pulmonary elastance (median 5.0 cm H 2 O/mL/kg predicted body weight vs median 3.2 cm H 2 O/mL/kg predicted body weight, P = .03).
Conclusions
Pendelluft reflecting increased regional lung stress and strain is likely common during spontaneous breathing effort in patients with AHRF but was not systematically affected by applying higher PEEP. The presence and magnitude of pendelluft depended on respiratory effort and lung mechanics.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Drs Bassi, Slutsky, and Brochard are affiliated with Interdepartmental Division of Critical Care Medicine, University of Toronto, Toronto, Ontario, Canada.
- Drs Dianti, Bellissimo, and Morris are affiliated with Interdepartmental Division of Critical Care Medicine, University of Toronto, Toronto, Ontario, Canada; and Department of Medicine, Division of Respirology, Universi…
- Ms Roman-Sarita is affiliated with Respiratory Therapy, Toronto General Hospital, Toronto, Ontario, Canada.
- Drs Ferguson and Goligher are affiliated with Interdepartmental Division of Critical Care Medicine, University of Toronto, Toronto, Ontario, Canada; Department of Medicine, Division of Respirology, University Health Net…
- Dr Zhao is affiliated with School of Biomedical Engineering, Guangzhou Medical University, Guangzhou, China; and Institute of Technical Medicine, Furtwangen University, Villingen-Schwenningen, Germany.
- Dr Yoshida is affiliated with Department of Anesthesiology and Intensive Care Medicine, Osaka University Graduate School of Medicine, Suita, Japan.
Zitieren
APA
Bassi, T., Dianti, J., Roman-Sarita, G., Bellissimo, C., Morris, I. S., Slutsky, A. S., Brochard, L., Ferguson, N. D., Zhao, Z., Yoshida, T., & Goligher, E. C. (2025). Effect of Higher or Lower PEEP on Pendelluft During Spontaneous Breathing Efforts in Acute Hypoxemic Respiratory Failure. Respiratory Care, 70(2), 126-133. https://doi.org/10.1089/respcare.12193
Vancouver
Bassi T, Dianti J, Roman-Sarita G, Bellissimo C, Morris IS, Slutsky AS, et al. Effect of Higher or Lower PEEP on Pendelluft During Spontaneous Breathing Efforts in Acute Hypoxemic Respiratory Failure. Respiratory Care. 2025;70(2):126-133. doi:10.1089/respcare.12193
BibTeX
@article{Bassi2025,
author = {Bassi, Thiago and Dianti, Jose and Roman-Sarita, Georgiana and Bellissimo, Catherine and Morris, Idunn S and Slutsky, Arthur S and Brochard, Laurent and Ferguson, Niall D and Zhao, Zhanqi and Yoshida, Takeshi and Goligher, Ewan C},
title = {Effect of Higher or Lower PEEP on Pendelluft During Spontaneous Breathing Efforts in Acute Hypoxemic Respiratory Failure},
journal = {Respiratory Care},
year = {2025},
volume = {70},
number = {2},
pages = {126--133},
doi = {10.1089/respcare.12193}
}
EUVIMED