EUVIMEDEUVIMED entdecken
Open Access

Comparison of Pneumotachometer and Portable Digital Turbine Spirometry for Field-Based Assessment: An Air Quality, Environment, and Respiratory Outcomes in Bronchopulmonary Dysplasia Study

Lana Mukharesh iD, Morgan Ryan iD, Lystra P Hayden iD, Suzanne E Dahlberg iD, Jonathan M Gaffin iD

Pediatric Allergy, Immunology, and Pulmonology · 2023

DOI: 10.1089/ped.2023.0046 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pediatric Allergy, Immunology, and Pulmonology, 2023. Verfasst von Lana Mukharesh und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatrics, Division of Pulmonary Medicine, Boston Children's Hospital, Boston, Massachusetts, USA. Hauptthemen laut MEDLINE: Bronchopulmonary Dysplasia, Biomedical Research, Precancerous Conditions, Air Pollution. Die Arbeit nennt 8 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NHLBI NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Data on the use of remote spirometry are limited in the pediatric population. We sought to assess the feasibility and accuracy of a digital turbine spirometer, Medical International Research (MIR) Spirobank Smart (MIR, New Berlin, WI, USA), compared with a pneumotachography spirometer, Pneumotrac (Vitalograph Inc., Lenexa, KS, USA), in field-based clinical research.

Methods

This is a cross-sectional study of a subgroup of school-aged participants enrolled in the Air quality, Environment, and Respiratory Outcomes in Bronchopulmonary Dysplasia (BPD) study, who performed same-day paired coached baseline spirometry measurements from the Pneumotrac and MIR devices. Proportion of successful tests was estimated for each device and compared using McNemar's test. Correlation between devices forced expiratory volume in 1 second (FEV 1 ) and forced vital capacity (FVC) was analyzed by Lin's concordance correlation, and Bland–Altman plots were generated.

Results

Twenty-one participants with history of BPD completed home spirometry maneuvers on both devices. The mean age of participants was 8.7 years. The mean FEV 1 and FVC measurement was 81% predicted and 90.4% predicted, respectively. The proportion of acceptable tests appeared higher using Pneumotrac (81%) than when using MIR (67%), although without evidence of discordance ( P = 0.317). Among subjects with successful tests on both devices, Lin's concordance correlation demonstrated moderate agreement (FEV 1 r = 0.955, 95% confidence interval [CI]: 0.87–0.98; FVC r = 0.971, CI: 0.91–0.99). The mean difference in FEV 1 between Pneumotrac and MIR was 0.079 L (95% limits of agreement were −0.141 to 0.298 L) and FVC was 0.075 L (95% limits of agreement were −0.171 to 0.322 L). These were relatively small and without evidence of systematic or volume-dependent bias.

Conclusions

Utilizing turbine spirometers may be a promising and feasible way to perform pulmonary function testing for field research in children.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Bronchopulmonary DysplasiaBiomedical ResearchPrecancerous ConditionsAir PollutionChildInfant, NewbornHumansFemaleCross-Sectional StudiesSpirometry

Stichwörter der Autor:innen

COVID-19bronchopulmonary dysplasiapediatricsremote spirometry

Autor:innen und Institutionen

  • Department of Pediatrics, Division of Pulmonary Medicine, Boston Children's Hospital, Boston, Massachusetts, USA.
  • Department of Pediatrics, Institutional Centers for Clinical and Translational Research (ICCTR), Boston Children's Hospital, Boston, Massachusetts, USA.
  • Department of Pediatrics, Harvard Medical School, Boston, Massachusetts, USA.

ORCID-Profile: Lana Mukharesh, Morgan Ryan, Lystra P Hayden, Suzanne E Dahlberg, Jonathan M Gaffin

Förderung

  • NHLBI NIH HHS

Zitieren

APA

Mukharesh, L., Ryan, M., Hayden, L. P., Dahlberg, S. E., & Gaffin, J. M. (2023). Comparison of Pneumotachometer and Portable Digital Turbine Spirometry for Field-Based Assessment: An Air Quality, Environment, and Respiratory Outcomes in Bronchopulmonary Dysplasia Study. Pediatric Allergy, Immunology, and Pulmonology. https://doi.org/10.1089/ped.2023.0046

Vancouver

Mukharesh L, Ryan M, Hayden LP, Dahlberg SE, Gaffin JM. Comparison of Pneumotachometer and Portable Digital Turbine Spirometry for Field-Based Assessment: An Air Quality, Environment, and Respiratory Outcomes in Bronchopulmonary Dysplasia Study. Pediatric Allergy, Immunology, and Pulmonology. 2023. doi:10.1089/ped.2023.0046

BibTeX
@article{Mukharesh2023,
  author = {Mukharesh, Lana and Ryan, Morgan and Hayden, Lystra P and Dahlberg, Suzanne E and Gaffin, Jonathan M},
  title = {Comparison of Pneumotachometer and Portable Digital Turbine Spirometry for Field-Based Assessment: An Air Quality, Environment, and Respiratory Outcomes in Bronchopulmonary Dysplasia Study},
  journal = {Pediatric Allergy, Immunology, and Pulmonology},
  year = {2023},
  doi = {10.1089/ped.2023.0046}
}
Kostenlos starten →