EUVIMEDEUVIMED entdecken
Vergleichsstudie

Characteristic Single Photon Emission Computed Tomography-Computed Tomography Findings in Lower Extremity Lymphedema: Comparison to Indocyanine Green Lymphography

Hayahito Sakai iD, Toko Miyazaki, Maya Kanasaki, Reiko Tsukuura, Takumi Yamamoto

Lymphatic Research and Biology · 2024

DOI: 10.1089/lrb.2023.0051 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Lymphatic Research and Biology, 2024. Verfasst von Hayahito Sakai und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Plastic and Reconstructive Surgery, National Center for Global Health and Medicine, Tokyo, Japan. Hauptthemen laut MEDLINE: Lymphedema, Indocyanine Green, Lymphography, Lower Extremity. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 22 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Evaluation of lymph circulation is significant in lower extremity lymphedema (LEL) management. Single-photon emission computed tomography-computed tomography (SPECT-CT) has been introduced for lymphedema evaluation, but its characteristic findings are yet fully clarified. The purpose of this study was to reveal typical SPECT-CT findings in secondary LEL by contrasting with indocyanine green (ICG) lymphography findings.

Methods

This is a single-center retrospective case–control study. Medical charts of cancer survivors who underwent SPECT-CT and ICG lymphography for secondary LEL were reviewed. Lymphedematous limbs were defined as ICG lymphography stage I–V and non-lymphedematous limbs were defined as ICG lymphography stage 0. Characteristic SPECT-CT findings were identified in early phase and delay phase, and prevalence of the findings was compared between lymphedematous limbs and non-lymphedematous limbs.

Results

Thirty-four limbs of 17 patients were included in this study; 6 (17.6%) non-lymphedematous limbs and 28 (82.4%) lymphedematous limbs. Four characteristic SPECT-CT findings were identified; delayed enhancement of the main lower leg lymphatic pathway (DML), few delayed inguinal lymph nodes enhancement (FDN), early phase discontinuous enhancement of the main lymphatic pathway (EDM), and nonenhancement of the deep lymphatic pathways in early phase (NDE). Between lymphedematous and non-lymphedematous limbs, there were statistically significant differences in FDN (64.3% vs. 0%, p = 0.004) and EDM (67.9% vs. 0%, p = 0.002).

Conclusions

FDN and EDM are characteristic SPECT-CT findings in secondary LEL.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LymphedemaIndocyanine GreenLymphographyLower ExtremitySingle Photon Emission Computed Tomography Computed TomographyHumansFemaleMaleMiddle AgedRetrospective StudiesAgedCase-Control StudiesAdult

Stichwörter der Autor:innen

ICG lymphographySPECT-CTlymphedema

Substanzen

Indocyanine Green

Autor:innen und Institutionen

  • Department of Plastic and Reconstructive Surgery, National Center for Global Health and Medicine, Tokyo, Japan.

ORCID-Profile: Hayahito Sakai

Zitieren

APA

Sakai, H., Miyazaki, T., Kanasaki, M., Tsukuura, R., & Yamamoto, T. (2024). Characteristic Single Photon Emission Computed Tomography-Computed Tomography Findings in Lower Extremity Lymphedema: Comparison to Indocyanine Green Lymphography. Lymphatic Research and Biology. https://doi.org/10.1089/lrb.2023.0051

Vancouver

Sakai H, Miyazaki T, Kanasaki M, Tsukuura R, Yamamoto T. Characteristic Single Photon Emission Computed Tomography-Computed Tomography Findings in Lower Extremity Lymphedema: Comparison to Indocyanine Green Lymphography. Lymphatic Research and Biology. 2024. doi:10.1089/lrb.2023.0051

BibTeX
@article{Sakai2024,
  author = {Sakai, Hayahito and Miyazaki, Toko and Kanasaki, Maya and Tsukuura, Reiko and Yamamoto, Takumi},
  title = {Characteristic Single Photon Emission Computed Tomography-Computed Tomography Findings in Lower Extremity Lymphedema: Comparison to Indocyanine Green Lymphography},
  journal = {Lymphatic Research and Biology},
  year = {2024},
  doi = {10.1089/lrb.2023.0051}
}
Kostenlos starten →