Validation of a Pulsatile Model for Laparoscopic Partial Nephrectomy: NEFPAR Model
Journal of Laparoendoscopic & Advanced Surgical Techniques · 2025
DOI: 10.1089/lap.2025.0026 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Journal of Laparoendoscopic & Advanced Surgical Techniques, 2025. Verfasst von Jose Antonio Campos Sañudo und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Urology, Dr. Sulaiman Al Habib Medical Group, Ar Rayyan Hospital, Riyhad, Saudi Arabia. Hauptthemen laut MEDLINE: Nephrectomy, Laparoscopy, Simulation Training, Models, Anatomic. Die Arbeit nennt 16 Literaturangaben.
Abstract (Originalsprache)
Background
Laparoscopic and robotic-assisted partial nephrectomy are the gold standard for treating small renal tumors. To improve training while adhering to animal welfare regulations, the NEFPAR pulsatile model was developed as a nonliving alternative for surgical simulation. This study aimed to validate NEFPAR as a realistic and effective training tool.
Methods
The NEFPAR model was constructed using porcine tissue used in other simulations, a pulsatile pump, and standard laparoscopic instruments. Eleven participants (4 urologists and 7 urology residents) were recruited for validation. They performed simulated laparoscopic partial nephrectomies using the model, and their performance was evaluated through a survey assessing the realism, educational impact, and comparison to other simulation models. Data were analyzed using Fisher's exact test, with significance set at P < .05.
Results
Most participants (72.7%) rated the NEFPAR model as realistic for key procedural steps, such as tumor resection and renal hilum dissection. The bleeding component was deemed essential for learning by 100% of participants. The NEFPAR model was superior to nonpulsatile animal models in replicating surgical bleeding and was comparable to cadaveric models in external appearance and tissue texture. However, cadaveric models were rated higher for replicating all procedural steps. No significant differences in responses were found between urologists and residents.
Conclusions
The NEFPAR model effectively simulates key aspects of laparoscopic partial nephrectomy and offers an ethical, cost-effective alternative for surgical training. It was well-received for its educational value, especially for simulating surgical bleeding. Further refinements could enhance tissue consistency and tumor positioning, but the model has strong potential to be integrated into urology training programs to improve surgical skills and reduce reliance on animal models.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Urology, Dr. Sulaiman Al Habib Medical Group, Ar Rayyan Hospital, Riyhad, Saudi Arabia.
- Hospital Virtual Valdecilla, Santander, Spain.
- Department of Urology, Hospital Universitario Marqués de Valdecilla; Research and Innovation Group in Surgery, IDIVAL, Santander, Spain.
ORCID-Profile: Jose Antonio Campos Sañudo
Zitieren
APA
Campos Sañudo, J. A., Higuera Pardo, S., & Ballestero Diego, R. (2025). Validation of a Pulsatile Model for Laparoscopic Partial Nephrectomy: NEFPAR Model. Journal of Laparoendoscopic & Advanced Surgical Techniques. https://doi.org/10.1089/lap.2025.0026
Vancouver
Campos Sañudo JA, Higuera Pardo S, Ballestero Diego R. Validation of a Pulsatile Model for Laparoscopic Partial Nephrectomy: NEFPAR Model. Journal of Laparoendoscopic & Advanced Surgical Techniques. 2025. doi:10.1089/lap.2025.0026
BibTeX
@article{CamposSaudo2025,
author = {Campos Sañudo, Jose Antonio and Higuera Pardo, Saul and Ballestero Diego, Roberto},
title = {Validation of a Pulsatile Model for Laparoscopic Partial Nephrectomy: NEFPAR Model},
journal = {Journal of Laparoendoscopic & Advanced Surgical Techniques},
year = {2025},
doi = {10.1089/lap.2025.0026}
}
EUVIMED