Use of Transesophageal Echocardiography for Enhanced Safety During Bar Removal Procedures After Minimally Invasive Repair of Pectus Excavatum
Journal of Laparoendoscopic & Advanced Surgical Techniques · 2023
DOI: 10.1089/lap.2022.0410 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Laparoendoscopic & Advanced Surgical Techniques, 2023. Verfasst von Preeya K Deol und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Medicine, University of North Carolina, Chapel Hill, North Carolina, USA. Hauptthemen laut MEDLINE: Funnel Chest. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 12 Literaturangaben.
Abstract (Originalsprache)
Background
Minimally invasive repair of pectus excavatum involves placement of retrosternal support (Nuss) bars. Hardware removal has been rarely associated with life-threatening hemorrhage from the heart, aorta, internal mammary arteries, and/or lung. There is no accepted standard intraoperative monitoring technique used during removal. We hypothesized that the use of transesophageal echocardiography (TEE) during Nuss bar removal would enhance safety of the procedure and be cost-effective.
Methods
IRB-approved retrospective review of patients who underwent Nuss bar removal with intraoperative TEE monitoring over a 4-year period, from March 2013 to May 2017, was completed. Bar removal procedures were performed supine, under general anesthesia. TEE images were monitored and any distortion of the cardiac silhouette, new pericardial effusion, and/or cardiac arrhythmias would be considered evidence of possible bar adherence, triggering possible conversion to sternotomy or thoracotomy.
Results
In total, 87 consecutive patients, mean age of 20 years, were identified. Bars had been in place for a mean of 30 months. Average procedure time was 67 minutes. No patients experienced arrhythmias, cardiac injury, or significant hemorrhage during removal. TEE gave excellent visualization of the cardiac silhouette and pericardium in all cases. No patient required insertion of an arterial line, a postoperative chest X-ray, or overnight hospitalization. Patients were discharged from the recovery room an average of 89 minutes postprocedure.
Conclusion
TEE offers a minimally invasive safe way to visualize the pericardium and its contents during Nuss bar removal. Significant cardiac/mediastinal injuries should be immediately visible. The use of TEE is cost-effective and allows safe discharge the day of surgery.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Medicine, University of North Carolina, Chapel Hill, North Carolina, USA.
- WakeMed Health and Hospitals, Pediatric Surgery, Raleigh, North Carolina, USA.
ORCID-Profile: Preeya K Deol, J Duncan Phillips
Zitieren
APA
Deol, P. K., Hoover, J. D., & Phillips, J. D. (2023). Use of Transesophageal Echocardiography for Enhanced Safety During Bar Removal Procedures After Minimally Invasive Repair of Pectus Excavatum. Journal of Laparoendoscopic & Advanced Surgical Techniques. https://doi.org/10.1089/lap.2022.0410
Vancouver
Deol PK, Hoover JD, Phillips JD. Use of Transesophageal Echocardiography for Enhanced Safety During Bar Removal Procedures After Minimally Invasive Repair of Pectus Excavatum. Journal of Laparoendoscopic & Advanced Surgical Techniques. 2023. doi:10.1089/lap.2022.0410
BibTeX
@article{Deol2023,
author = {Deol, Preeya K and Hoover, J David and Phillips, J Duncan},
title = {Use of Transesophageal Echocardiography for Enhanced Safety During Bar Removal Procedures After Minimally Invasive Repair of Pectus Excavatum},
journal = {Journal of Laparoendoscopic & Advanced Surgical Techniques},
year = {2023},
doi = {10.1089/lap.2022.0410}
}
EUVIMED