Comparison of Low-Frequency or High-Frequency Electrical Acupoint Stimulation on Hypotension After Spinal Anesthesia in Parturients: A Prospective Randomized Controlled Clinical Trial
Journal of Integrative and Complementary Medicine · 2024
DOI: 10.1089/jicm.2023.0610 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Journal of Integrative and Complementary Medicine, 2024. Verfasst von Xiaoyu Liu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, Xijing Hospital, Air Force Medical University, Xi'an, China. Hauptthemen laut MEDLINE: Anesthesia, Spinal, Hypotension, Acupuncture Points. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 24 Literaturangaben.
Abstract (Originalsprache)
Objective
To investigate whether transcutaneous electrical acupoint stimulation (TEAS) at PC6 could reduce hypotension after spinal anesthesia (SA) in parturients and to compare the effect of TEAS at different frequencies.
Methods
From February 20, 2023, to August 29, 2023, 90 parturients scheduled for c-section under SA were randomly assigned to receive no treatment (Control), TEAS at high frequency (TEAS-HF), or TEAS at low frequency (TEAS-LF). Treatments started immediately after SA and lasted for 30 min. The primary endpoint was incidence of hypotension by 30 min after SA. Secondary endpoints included lowest systolic blood pressure (SBP) during 30 min after SA, dose of ephedrine, dose of atropine, Apgar score at 1 min, and adverse events, including nausea, vomiting, dizziness, dyspnea, and chest congestion.
Results
In the TEAS-HF group, the incidence of hypotension by 30 min after SA was lower (13.3%) than in the Control (53.3%, p = 0.001; OR 1.9, 95% confidence interval [CI]: 1.2-2.8) and TEAS-LF group (40.0%, p = 0.02, OR 1.4, 95% CI: 1.0-2.0). The lowest SBP during 30 min after SA was higher in the TEAS-HF group (100.0 ± 9.4 mm Hg) than in the Control group (91.5 ± 16.5 mm Hg) and TEAS-LF group (93.9 ± 16.6 mm Hg). Patients who received TEAS showed a lower score of nausea and vomiting (both p = 0.02). Patients in the group TEAS-HF showed a lower incidence of dizziness, dyspnea, and of chest congestion than those in the other two groups. There was no difference with respect to atropine consumption and neonatal Apgar score.
Conclusions
TEAS-HF at PC6 reduced hypotension after SA in parturients, while TEAS-LF did not.
Trial registration
ClinicalTrials.gov (NCT05724095).
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Anesthesiology, Xijing Hospital, Air Force Medical University, Xi'an, China.
ORCID-Profile: Zhihong Lu
Zitieren
APA
Liu, X., Gao, Z., Jiang, Y., Tuo, X., He, S., Xu, F., & Lu, Z. (2024). Comparison of Low-Frequency or High-Frequency Electrical Acupoint Stimulation on Hypotension After Spinal Anesthesia in Parturients: A Prospective Randomized Controlled Clinical Trial. Journal of Integrative and Complementary Medicine. https://doi.org/10.1089/jicm.2023.0610
Vancouver
Liu X, Gao Z, Jiang Y, Tuo X, He S, Xu F, et al. Comparison of Low-Frequency or High-Frequency Electrical Acupoint Stimulation on Hypotension After Spinal Anesthesia in Parturients: A Prospective Randomized Controlled Clinical Trial. Journal of Integrative and Complementary Medicine. 2024. doi:10.1089/jicm.2023.0610
BibTeX
@article{Liu2024,
author = {Liu, Xiaoyu and Gao, Zijun and Jiang, Yongzhou and Tuo, Xiaoshuang and He, Shan and Xu, Feifei and Lu, Zhihong},
title = {Comparison of Low-Frequency or High-Frequency Electrical Acupoint Stimulation on Hypotension After Spinal Anesthesia in Parturients: A Prospective Randomized Controlled Clinical Trial},
journal = {Journal of Integrative and Complementary Medicine},
year = {2024},
doi = {10.1089/jicm.2023.0610}
}
EUVIMED