EUVIMEDEUVIMED entdecken
Open Access

Characterization of Spray-Dried Powders Using a Coated Alberta Idealized Nasal Inlet

Kelvin Duong iD, Maximilian Aisenstat, John Z Chen, Brynn Murphy, Scott Tavernini, Hui Wang, Béla Reiz, Jing Zheng, Randy Whittal, Wynton D McClary iD, Alana Gerhardt, Christopher B Fox und 3 weitere

Journal of Aerosol Medicine and Pulmonary Drug Delivery · 01.02.2025 · 38 (1) · 1-12

DOI: 10.1089/jamp.2024.0029 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Aerosol Medicine and Pulmonary Drug Delivery, online erschienen am 03.02.2025. Verfasst von Kelvin Duong und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, University of Alberta, Edmonton, Canada. Hauptthemen laut MEDLINE: Trehalose, Dry Powder Inhalers, Drug Delivery Systems. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Dry powders offer the potential to increase stability and reduce cold-chain requirements associated with the distribution of vaccines and other thermally sensitive products. The Alberta Idealized Nasal Inlet (AINI) is a representative geometry for in vitro characterization of nasal products that may prove useful in examining intranasal delivery of powders.

Methods

Spray-dried trehalose powders were loaded at 10, 20, and 40 mg doses into active single-dose devices. Primary particle sizes (∼ D v 50 = 10 µm for powder A and 25 µm for powder B), and sizes dispersed by devices, were evaluated using laser diffraction. The interior of the AINI was coated with a glycerol-surfactant mixture to mitigate particle bounce, and flow rates of 7.5 or 15 L/min were drawn through the AINI. Deposition of trehalose powder was determined in the four regions of the AINI (vestibule, turbinates, olfactory, and nasopharynx), a downstream preseparator, and an absolute filter (representing in vitro lung deposition) using liquid chromatography coupled with mass spectrometry.

Results

Coating the AINI was effective in mitigating particle bounce for both trehalose powders. No difference in regional nasal deposition was observed when testing at a flow rate of 7.5 versus 15 L/min. A high fraction of both powders penetrated past the vestibule and deposited in the turbinates and nasopharynx for all loaded doses. For powder A, a non-negligible fraction of the recovered dose (up to 7%) is deposited on the filter, representing potential lung exposure. Conversely, a negligible fraction of the total recovered dose was deposited on the filter for powder B.

Conclusion

Powders with a larger primary particle size showed reduced penetration through the nasal airways while maintaining high turbinate deposition. Optimized spray-dried powders offer the potential to target delivery to the peripheral nasal airways based on powder particle size while reducing lung exposure.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TrehaloseDry Powder InhalersDrug Delivery SystemsPowdersAdministration, IntranasalParticle SizeSpray DryingHumansEquipment DesignAerosols

Stichwörter der Autor:innen

in vitronasal drug deliverynasal geometrynasal powderparticle engineeringregional depositionspray drying

Substanzen

PowdersTrehaloseAerosols

Autor:innen und Institutionen

  • Department of Mechanical Engineering, University of Alberta, Edmonton, Canada.
  • Access to Advanced Health Institute (AAHI), Seattle, Washington, USA.
  • Department of Chemistry, University of Alberta, Edmonton, Canada.
  • Department of Biomedical Engineering, University of Alberta, Edmonton, Canada.

ORCID-Profile: Kelvin Duong, Wynton D McClary, Reinhard Vehring

Zitieren

APA

Duong, K., Aisenstat, M., Chen, J. Z., Murphy, B., Tavernini, S., Wang, H., Reiz, B., Zheng, J., Whittal, R., McClary, W. D., Gerhardt, A., Fox, C. B., Finlay, W. H., Vehring, R., & Martin, A. R. (2025). Characterization of Spray-Dried Powders Using a Coated Alberta Idealized Nasal Inlet. Journal of Aerosol Medicine and Pulmonary Drug Delivery, 38(1), 1-12. https://doi.org/10.1089/jamp.2024.0029

Vancouver

Duong K, Aisenstat M, Chen JZ, Murphy B, Tavernini S, Wang H, et al. Characterization of Spray-Dried Powders Using a Coated Alberta Idealized Nasal Inlet. Journal of Aerosol Medicine and Pulmonary Drug Delivery. 2025;38(1):1-12. doi:10.1089/jamp.2024.0029

BibTeX
@article{Duong2025,
  author = {Duong, Kelvin and Aisenstat, Maximilian and Chen, John Z and Murphy, Brynn and Tavernini, Scott and Wang, Hui and Reiz, Béla and Zheng, Jing and Whittal, Randy and McClary, Wynton D and Gerhardt, Alana and Fox, Christopher B and Finlay, Warren H and Vehring, Reinhard and Martin, Andrew R},
  title = {Characterization of Spray-Dried Powders Using a Coated Alberta Idealized Nasal Inlet},
  journal = {Journal of Aerosol Medicine and Pulmonary Drug Delivery},
  year = {2025},
  volume = {38},
  number = {1},
  pages = {1--12},
  doi = {10.1089/jamp.2024.0029}
}
Kostenlos starten →