Developmental Validation of the PowerPlex® 35GY System: An 8-Dye STR Multiplex for Human Identification Applications
Forensic Genomics · 01.06.2024 · 4 (2) · 47-65
DOI: 10.1089/forensic.2024.0006 ↗Kurz gefasst
Fachartikel in der Zeitschrift Forensic Genomics, online erschienen am 22.06.2024. Verfasst von Erica K. Graham und 22 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The PowerPlex ® 35GY System is a 35-locus, eight-dye, STR multiplex optimized for use with Spectrum CE Systems. It simultaneously amplifies all CODIS and ESS markers, along with Amelogenin and DYS391 for gender determination. Penta D, Penta E, and SE33 are included for expanded database searching capability. Ten additional nonrapidly mutating Y-STR loci are included to enable familial searching and to assist with forensic casework on sexual assault evidence. Lastly, two Quality Indicators are added to provide indications of sample quality and amplification performance. The PowerPlex ® 35GY System is designed to amplify DNA from purified extracts as well as direct amplification of database sample substrates. The availability of 8 colors allows the inclusion of smaller, more numerous loci, thus increasing a laboratory’s chance of success with challenging samples. A multilaboratory developmental validation study was performed for the PowerPlex ® 35GY System following SWGDAM guidelines. The results of the study demonstrate the reliability and robustness of the PowerPlex ® 35GY System for use in human identification DNA typing applications.
Zitieren
APA
Graham, E. K., Lauck, M., Picciano, J. A., Seifarth, J. J., Drobac, J. M., Vallone, P. M., Steffen, C. R., O’Donnell, M., Sullivan, N. P., Parker, C., Moreno, L. I., Zaky, M., Flanagan, L., Fernández-Serrano, J. J., Martínez-Gómez, J., Lenz, K. A., McDaniel, S. L., Rabbach, D. R., Divakaran, K., …, & Thompson, J. M. (2024). Developmental Validation of the PowerPlex® 35GY System: An 8-Dye STR Multiplex for Human Identification Applications. Forensic Genomics, 4(2), 47-65. https://doi.org/10.1089/forensic.2024.0006
Vancouver
Graham EK, Lauck M, Picciano JA, Seifarth JJ, Drobac JM, Vallone PM, et al. Developmental Validation of the PowerPlex® 35GY System: An 8-Dye STR Multiplex for Human Identification Applications. Forensic Genomics. 2024;4(2):47-65. doi:10.1089/forensic.2024.0006
BibTeX
@article{Graham2024,
author = {Graham, Erica K. and Lauck, Michael and Picciano, John A. and Seifarth, Jessica J. and Drobac, Jon M. and Vallone, Peter M. and Steffen, Carolyn R. and O’Donnell, Megan and Sullivan, Nisha P. and Parker, Caroline and Moreno, Lilliana I. and Zaky, Monica and Flanagan, Lori and Fernández-Serrano, José J. and Martínez-Gómez, Jesús and Lenz, Kristy A. and McDaniel, Stephen L. and Rabbach, Dawn R. and Divakaran, Karthika and McLaren, Robert S. and Storts, Douglas R. and Sprecher, Cynthia J. and Thompson, Jonelle M.},
title = {Developmental Validation of the PowerPlex® 35GY System: An 8-Dye STR Multiplex for Human Identification Applications},
journal = {Forensic Genomics},
year = {2024},
volume = {4},
number = {2},
pages = {47--65},
doi = {10.1089/forensic.2024.0006}
}
EUVIMED