The Evaluation of Computer Vision-Based Automated Performance Metrics for Endoscopic Kidney Stone Surgery
Journal of Endourology · 2025
DOI: 10.1089/end.2024.0895 ↗Kurz gefasst
Evaluationsstudie in der Zeitschrift Journal of Endourology, 2025. Verfasst von Jackson Cabo und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Urology, Vanderbilt University Medical Center, Nashville, Tennessee, USA. Hauptthemen laut MEDLINE: Kidney Calculi, Ureteroscopy, Endoscopy. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIDDK NIH HHS.
Abstract (Originalsprache)
Background
The assessment of surgical competency is essential for clinical training and safety. No objective, real-time tools exist to evaluate competency during endoscopic stone operation. We sought to apply endoscopic computer vision models to define automated performance metrics (APMs) from videos of flexible ureteroscopy. Materials and Methods: We assessed three APMs for endoscopic treatment of kidney stones, including percentage of frames without stone visibility, screen occupancy by stone, and frame-to-frame change in stone occupancy. Surgical videos of a surgeon performing either stone localization or stone ablation were recorded. Using our previously validated computer vision model for endoscopic stone segmentation, APMs were compared between experts (fellowship-trained endourologists) and trainees.
Results
Forty-six videos, including 28 of stone localization and 18 of stone laser ablation, were analyzed from nine surgeons (three experts and six trainees). During stone localization, trainee videos had a higher percentage of frames without visible stone (4% vs 27%, p < 0.01) and lower screen occupancy by stone (5% vs 14%, p = 0.03) compared with expert videos. During laser ablation, trainee videos had a higher frame-to-frame change in stone occupancy (3% vs 2%, p < 0.01) compared with expert videos.
Conclusions
APMs from computer vision methods differ between expert and trainee surgical videos of endoscopic kidney stone treatment. These metrics could be used to objectively assess skill evaluation and acquisition.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Urology, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
- Department of Urology, Mayo Clinic Arizona, Phoenix, Arizona, USA.
- Department of Computer Science, Vanderbilt University, Nashville, Tennessee, USA.
- University of South Carolina School of Medicine, Columbia, South Carolina, USA.
- Department of Biostatistics, VUMC, Nashville, Tennessee, USA.
Förderung
- NIDDK NIH HHS
Zitieren
APA
Cabo, J., Lu, D., Floyd, C., Koyama, T., Oguz, I., & Kavoussi, N. (2025). The Evaluation of Computer Vision-Based Automated Performance Metrics for Endoscopic Kidney Stone Surgery. Journal of Endourology. https://doi.org/10.1089/end.2024.0895
Vancouver
Cabo J, Lu D, Floyd C, Koyama T, Oguz I, Kavoussi N. The Evaluation of Computer Vision-Based Automated Performance Metrics for Endoscopic Kidney Stone Surgery. Journal of Endourology. 2025. doi:10.1089/end.2024.0895
BibTeX
@article{Cabo2025,
author = {Cabo, Jackson and Lu, Daiwei and Floyd, Chase and Koyama, Tatsuki and Oguz, Ipek and Kavoussi, Nicholas},
title = {The Evaluation of Computer Vision-Based Automated Performance Metrics for Endoscopic Kidney Stone Surgery},
journal = {Journal of Endourology},
year = {2025},
doi = {10.1089/end.2024.0895}
}
EUVIMED